Included in every Ingro EMS

One Integration Layer for All Your BESS Hardware

Any BMS, PCS, inverter, meter or relay, from any manufacturer. Ingro EMS reads each device in its own protocol, translates it into one data model and runs the site from it, so you choose hardware on merit and avoid vendor lock-in.

VENDOR A · LFPVENDOR B · LFPingroDGCAN 2.0BBMS · cell levelModbus TCPPCS · any makeIEC 61850Relays · GOOSESunSpecPV invertersModbus RTUDG set · RS485OPC-UAPlant SCADA · PLCOne data modelWHAT THE DEVICES SENDWHAT THE EMS SEESCAN 0x18FF50E5battery.soc82.4 %HR 40084 = 0x04E2pcs.p_kw1,250 kWSunSpec 103.Wpv.p_kw2,940 kWRS485 id 7 · 0x0031dg.statestandbyXCBR1.Pos.stValgrid.breakerclosedns=2;s=Line3.kWplant.load_kw3,610 kWSLDC / RLDCDNP3 · IEC 61850Ingro CloudFleet view · reportsYour SCADA or APIREST · WebSocket
7+
Protocols Supported
40+
Hardware Drivers
≤20 ms
Control Response
0
Vendor Lock-In
  • Any makeBMS, PCS, inverter, meter, relay or DG
  • Offline-capableControl stays on site when the link drops
  • Tata PowerA vendor-locked grid BESS, opened up
Why Integrations Matter

No Two BESS Sites
Are Identical

A grid-scale project in Rajasthan uses cells from two manufacturers with Sungrow PCS, and reports to the SLDC over DNP3. A data centre in Hyderabad runs BYD modules with SMA PCS and connects to the building management system over OPC-UA. A microgrid in the North-east uses a custom Indian BMS over CAN bus, with satellite backhaul over MQTT.

The EMS that runs all three sites must support every protocol, understand every register map, and normalise every data format into one coherent picture. That is what Ingro's integration layer does. It is the common layer that lets Cloud EMS, Ingro Brain and Battery Passport work with any hardware ecosystem.

Three sites, three hardware stacks, one data modelA grid-scale BESS in Rajasthan, a data centre in Hyderabad and a remote microgrid in the North-east each use different batteries, field links and upstream protocols. All three feed the same Ingro EMS data model.Grid-scale BESSRajasthanBATTERYCells from two makersFIELD LINKModbus TCP · SungrowUPSTREAMDNP3 to the SLDCData centreHyderabadBATTERYBYD modulesFIELD LINKModbus TCP · SMAUPSTREAMOPC-UA to building BMSRemote microgridNorth-east IndiaBATTERYCustom Indian BMSFIELD LINKCAN bus to the BMSUPSTREAMMQTT over satelliteIngro EMS · one data modelSame tags, same control logic, same reports on all three sites
The Problem

Vendor Lock-In Is
a Major Risk in BESS

When your EMS only works with one BMS brand, one inverter model or one communication protocol, you are locked in. Costs rise, options narrow and your BESS cannot be upgraded.

Hardware Tied to Software

Most EMS platforms only work with their own brand of BMS or inverter. When you need to expand capacity or replace failed modules, you have to buy from the same vendor, regardless of price or quality.

Proprietary Protocols

Closed communication protocols keep your BESS data inside a single vendor's ecosystem. You cannot integrate with third-party analytics, trading platforms, or fleet management tools.

Blocked Upgrades

When better, cheaper hardware becomes available (new LFP cells, more efficient PCS, smarter meters), a locked-in system cannot adopt it, and your BESS falls behind the rest of the industry.

Ingro's Answer

Hardware Freedom

Our integration layer decouples your software from your hardware. Choose suitable components from any manufacturer, change hardware when better options emerge, and protect your BESS investment over its life. When you upgrade inverters or add new battery modules, the software adapts: a new device is a driver file, not a new EMS.

A closed EMS only talks to its own vendor's BMS; Ingro EMS connects to vendor A, vendor B and next year's PCS.CLOSED EMSVendor A EMSVendor ABMSVendor BBMSNew PCSnext yearINGRO EMSIngro EMSVendor ABMSVendor BBMSNew PCSnext year
Protocol Support

Seven Protocols.
Every Device.

From legacy serial Modbus to modern cloud APIs, Ingro supports the protocols used by every device in your BESS, from the cell up to the grid operator.

INGRO EMS
  1. Enterprise and cloud

    Ingro Cloud, your dashboards, trading and portfolio systems

    REST & WebSocketMQTT
  2. Grid operator

    SLDC and RLDC telemetry and dispatch

    DNP3IEC 61850 MMS
  3. Substation and plant

    Protection relays, plant SCADA, PLCs and building systems

    IEC 61850 GOOSEOPC-UA
  4. Devices

    PCS, inverters, meters and DG controllers

    Modbus TCPModbus RTU · RS485SunSpec
  5. Cells

    BMS cell voltages, temperatures and balancing state

    CAN 2.0B / CAN FD

Modbus TCP/RTU

The Workhorse
Devices

Connects to 90% of BMS, inverter, and meter hardware in the field. Ingro maintains register maps for every major manufacturer, so integration is configuration rather than weeks of manual work.

  • TCP and RTU (serial RS-485) support
  • Pre-built register maps for the major BESS manufacturers
  • SunSpec information models for PV and storage inverters
  • Custom register mapping tool for proprietary BMS firmware
  • Multi-drop support for daisy-chained devices on a single bus

IEC 61850

Utility-Grade
Substation and grid

The established standard for grid-connected BESS. Required by most SLDCs and RLDCs for substation-level integration. Ingro supports MMS, GOOSE, and Sampled Values for full SCADA interoperability.

  • MMS (Manufacturing Message Specification) for SCADA data exchange
  • GOOSE messaging for sub-4 ms protection signalling
  • Sampled Values (SV) for high-resolution waveform capture
  • ICD/SCD file generation for SLDC onboarding

DNP3

Distribution Automation
Grid operator

The protocol of choice for SLDC/RLDC communication across Indian distribution networks. Ingro supports Level 2 and Level 3 compliance for both outstation and master station roles.

  • Level 2 and Level 3 outstation compliance
  • Unsolicited response mode for real-time event reporting
  • Secure authentication (SA v5) for tamper-proof communication
  • Tested and certified with major Indian SLDC systems

OPC-UA

Modern Industrial IoT
Plant and site

A modern industrial protocol: secure, scalable and firewall-friendly. Ideal for brownfield integration where the BESS sits alongside existing factory automation or building management systems.

  • Client and server mode for bidirectional data exchange
  • Built-in security: X.509 certificates, encrypted channels
  • Information modelling for structured, self-describing data
  • Firewall-friendly, works over standard HTTPS ports

REST & WebSocket APIs

Cloud-to-Cloud
Enterprise and cloud

For integration with the broader energy ecosystem: CPO platforms, energy trading systems, weather services, and third-party analytics dashboards. Webhooks push events as they happen.

  • RESTful endpoints for configuration and telemetry queries
  • WebSocket streams for live telemetry and alarms
  • Webhook subscriptions for real-time alarm and event notifications
  • OAuth 2.0 and API key authentication

MQTT

Lightweight IoT
Remote links

Purpose-built for edge devices and remote microgrids with limited or intermittent connectivity. QoS levels ensure data delivery even over unreliable satellite or cellular links.

  • QoS 0/1/2 for guaranteed message delivery
  • Last Will and Testament for device disconnect detection
  • Retained messages for instant state sync on reconnect
  • TLS-encrypted broker connections with certificate pinning

CAN Bus

Cell-Level Access
Cells

Direct communication with battery management systems at the cell level. Bypasses high-level abstractions to extract raw voltage, temperature, and impedance data from individual cells.

  • CAN 2.0B and CAN FD support for high-throughput data
  • DBC file parsing for manufacturer-specific message decoding
  • Cell-level voltage and temperature at 1-second resolution
  • Critical for Ingro Brain health analytics and Battery Passport data

Want an engineer to call you?

Leave your details. An Ingro engineer gets back to you within one business day, no obligation.

Or tell us about your site ↓
Hardware Compatibility

Works With the Equipment
You Already Have

Pre-built drivers for 40+ manufacturers across BMS, inverters, meters, SCADA, protection relays and generators. If your hardware speaks a standard protocol, Ingro can integrate it.

Battery Management Systems

Modbus / CAN Bus
Multiple global BESS manufacturersLG Chem RBMS (legacy)Custom Indian BMS

Inverters & PCS

Modbus / SunSpec / OPC-UA
SMASungrowSinengDeltaABBSchneider

Grid Meters

Modbus / DNP3
SecureHPLL&TABBSchneider

SCADA & PLC

OPC-UA / IEC 61850
SiemensAllen BradleySchneiderBeckhoff

Protection Relays

IEC 61850 GOOSE
ABBSiemensGESchneider

Generators & DG Controllers

Modbus RTU / Digital I/O
Any Modbus DG controllerDry-contact start / stop

Hardware not listed? Talk to our engineering team. We build custom drivers for any equipment that speaks a standard protocol.

Building a BESS and choosing whose EMS goes in it? Eight questions to ask of any BESS EMS

Architecture

Edge Control and Cloud Scale
in One Architecture

A four-layer architecture that collects data locally, abstracts hardware differences, enables hot-swappable drivers and enforces defence-in-depth security.

Layer 1

Edge Gateway

An industrial-grade controller in the plant room running Ingro's edge software. It collects data from every field device, executes critical control loops locally, and syncs with the cloud over encrypted channels.

  • Local control loop specified per project, from sub-1 ms to 20 ms, for safety-critical operations
  • Local data buffering, no data loss during connectivity drops
  • Automatic failover: edge takes full control if cloud is unreachable
  • Remote firmware updates with rollback capability
The edge controller reads field devices and runs the control loop on site; if the cloud link drops, it keeps running and buffers data until the link returns.ON SITEBMSPCSMeterRelaysIngro EMSedge controllerLoop: sub-ms to 20 msCLOUDLink down?Site keeps runningLOCAL BUFFERSyncs on reconnect
Layer 2

Protocol Abstraction Layer

Hardware-specific register maps, message formats, and data types are abstracted into a unified data model. Cloud EMS and Ingro Brain see the same clean data structure, whichever make of BMS, PCS or meter it came from and whichever protocol carried it.

  • Unified data model: same API whether the BMS is from a global manufacturer or custom-built
  • Automatic unit conversion and scaling across manufacturers
  • Timestamp synchronisation across devices with different clocks
  • Data quality scoring: flags stale, out-of-range or missing values
Three vendors report state of charge three different ways; the abstraction layer turns all of them into one tag, battery.soc, with units, a timestamp and a quality flag.THREE WAYS TO SAY STATE OF CHARGEVendor A BMSHR 30845 × 0.1Vendor B BMSCAN 0x355 · b0–1Vendor C BESSZBAT1.SoC.magbattery.soc82.4 %quality good · 12:04:05.120UnitsTimestampQuality
Layer 3

Hot-Swappable Drivers

Adding support for new hardware does not require firmware updates or site visits. Load a driver configuration file, map registers to the unified model, and the new device is online in minutes.

  • JSON/YAML driver configuration, no compiled code changes
  • Live reload: new drivers activate without restarting the edge gateway
  • Driver versioning and rollback for safe updates
  • A driver library that grows with every deployment
A driver file maps the registers of a new PCS to the data model; on reload the device comes online with its points, and the previous driver version is kept for rollback.pcs-vendor-x.yamldevice: pcs_vendor_xprotocol: modbus_tcppoints: p_kw: { reg: 40200, scale: 0.1 } q_kvar: { reg: 40202, scale: 0.1 } state: { reg: 40010, map: states }v1.4 · rollback to v1.3LIVERELOADNew PCSOnlinep_kw1,250q_kvar−84staterunningNo restart, no site visit
Layer 4

Cybersecurity

Energy infrastructure requires defence-in-depth. Ingro's integration layer enforces strict security boundaries between IT and OT networks, with encryption, authentication, and access control at every layer.

  • TLS 1.3 encryption for all data in transit
  • X.509 certificate-based device authentication
  • Role-based access control (RBAC) for every API and command
  • Network segmentation between IT (cloud) and OT (field devices)
Field devices sit in an isolated OT network. The edge controller is the only bridge to the cloud, over TLS 1.3 with X.509 device certificates, and every user action is checked against a role.OT NETWORKBMSPCSMetersRelaysIT AND CLOUDAdminconfigureOperatordispatchViewerread onlyRBAC on every commandEdge controllerthe only bridgeTLS 1.3X.509 certs
How It Runs

From Hardware List
to Live Site

Every integration follows the same five steps, whether it is a new build or a retrofit of a locked system.

  1. 1

    Hardware list and drawings

    You send the make, model and firmware of each device, with the single-line diagram and network layout. Anything unclear goes on a site-survey list.

  2. 2

    Point list and register maps

    Every signal the EMS needs is listed, then matched to an existing driver or mapped from the device manual. Undocumented protocols are decoded from live captures.

  3. 3

    Tested against your plant model

    Drivers and control logic run against a simulation of your site before anything ships, including communication loss and adverse conditions.

  4. 4

    Point-to-point commissioning

    On site, each point is checked end to end, from device register to EMS screen to the SLDC where required, and the results are recorded.

  5. 5

    Handover and support

    Point list, driver versions and network drawings handed over as documentation, operators trained, and a defined support route. New devices later are added as configuration.

What to send us

This is enough for an integration scope and a quotation. Missing pieces are fine: we collect them on a site survey.

  • Make, model and firmware of each BMS, PCS, inverter, meter and relay
  • Communication manuals or register maps, if you have them
  • The single-line diagram and the network layout
  • Grid-operator telemetry list or connection agreement
  • What the site must deliver: tariff savings, grid services, backup
FAQ

BESS Integrations,
Answered

What buyers, integrators and plant owners ask before connecting their hardware to Ingro EMS.

7 questions

The energy management system is not tied to one maker's battery, PCS or meter. Ingro EMS reads each device in its own protocol, maps it into one data model and runs the same control logic and reports whatever the hardware underneath. You can buy, expand or replace equipment on price and quality instead of on compatibility.

Yes. Device integration is register-map driven, so a model not previously encountered is added as configuration: we map its registers or messages to the data model and test them point by point. It does not need new firmware or a new controller. If a vendor does not publish its protocol, we work from the device documentation and live captures, as we did with the legacy LG Chem rack BMS at Tata Power's Rohini BESS.

Yes. For grid-connected plants the EMS exchanges telemetry and dispatch signals with the load dispatch centre over DNP3 or IEC 61850, directly or through the plant power controller (PPC), depending on how the connection agreement is written.

The make, model and firmware version of each BMS, PCS, inverter, meter and relay; their communication manuals or register maps if you have them; the single-line diagram; the network layout; and any grid-operator telemetry list. If some of this is missing, we can collect it on a site survey.

In the field: Modbus TCP, Modbus RTU over RS485, SunSpec, IEC 61850, DNP3 and OPC-UA, plus dry contacts, digital I/O and aggregator gateways. CAN bus is used for cell-level BMS data, and MQTT for low-bandwidth and satellite links. Upstream, customers connect their own SCADA, corporate dashboard or portfolio system over REST and WebSocket interfaces.

Yes. In on-site and hybrid deployments, control runs on the edge controller in the plant room, so dispatch, interlocks and protection logic carry on with no internet connection. Telemetry is buffered locally and synced to the cloud when the link returns.

Yes. Replacing a locked or underperforming controller is a standard retrofit: we take an inventory of the existing devices and protocols, map them into Ingro EMS, test against the live plant and cut over with the site's own values. Our Smart Retrofit service covers it end to end.

Still have a question?

Share details of your site, hardware and tariff or tender, and an engineer will answer it.

Proof in the Field

A Vendor-Locked Battery,
Opened Up

Integration claims are easy to make. This is what one looks like on a live, ageing, grid-connected plant.

India's First Grid-Scale BESS: Tata Power Delhi Distribution Limited (TPDDL)

Tata Power Delhi Distribution Limited (TPDDL)

India's First Grid-Scale BESS · Rohini, Delhi

10 MW / 10 MWh, built in 2019 on a closed platform

India's first grid-scale BESS was commissioned on the Fluence Advancion platform with LG Chem NMC racks. When Ingro took over its EMS and SCADA, the rack BMS spoke Modbus TCP, the cell monitors spoke CAN, and the protocol was not published. We reverse-engineered the RBMS protocol and brought every rack and every cell into one data model. The system has kept running well beyond its original design expectations.

124
PCS units coordinated
37 × 196
Racks × cells read live
Modbus + CAN
Legacy links translated
6+ yrs
Plant in service
Read the Tata Power project

Works With Your Hardware. Verified on Site.

Tell us what BMS, inverters, meters and SCADA you use. We show exactly how Ingro integrates with them: protocols, data models and deployment timeline.