Most solar panels sold in India today are made with one of three cell technologies: Mono PERC, TOPCon or HJT. The name is printed on every datasheet and quotation, and it does tell you something, but it is not a grade. Two panels with the same label can differ more than two panels with different labels. This guide explains what each technology is, how they compare on efficiency, heat, bifacial output, degradation and warranty, and how to read a datasheet so you compare the panels in front of you rather than the label. The figures come from published research and from the datasheets of the 365 current panels in our directory, with each source named.
All three are crystalline silicon cells. They differ in the type of silicon wafer and in how the cell's surfaces are treated to stop electrical charge from being lost before it reaches the wires. Fraunhofer ISE's Photovoltaics Report (July 2026) defines the terms used below.
PERC stands for passivated emitter and rear cell. It is usually made on a p-type wafer, which Fraunhofer ISE describes as silicon doped with boron or gallium. A passivation layer on the back of the cell reflects light back in and reduces losses at the rear surface. PERC was the mainstream technology for years, so it is the one most installers know best.
TOPCon stands for tunnel oxide passivated contact. It is made on an n-type wafer, which Fraunhofer ISE describes as silicon doped with phosphorus, and adds a very thin oxide layer and a doped silicon layer at the rear contact to cut losses further. Fraunhofer ISE's report says monocrystalline n-type TOPCon 'has become dominant' in world production.
HJT, also called HIT, is a heterojunction with an intrinsic thin layer: an n-type crystalline wafer coated on both sides with thin layers of amorphous silicon. All 9 current HJT models in our directory are bifacial.
A fourth group you will see on the market moves all the electrical contacts to the back of the cell, so the front has no metal fingers shading it. Fraunhofer ISE lists the best-known form as IBC, interdigitated back contact. It shows up in our directory as its own technology.
Our directory lists 365 current solar panel models from 34 makers selling in India, each checked against the maker's datasheet in November 2026. By technology: TOPCon 160 models (44%), Mono PERC 128 (35%), back-contact 41 (11%) and HJT 9 (2%). The other 27 (7%) are other technologies or don't state one. This is a count of models listed, not of panels sold.
World production has moved further. Fraunhofer ISE's report puts n-type wafers at 86% of silicon wafer production in 2025, citing the ITRPV roadmap, and notes that n-type TOPCon and heterojunction are replacing p-type PERC. In India, PERC models are still widely listed, which matters if you are comparing quotes: you may be offered either.
On efficiency, the medians of what each datasheet prints as maximum module efficiency in our directory are: Mono PERC 21.3% (109 models print it), TOPCon 23.3% (129 models), HJT 23.7% (9 models from 4 makers, a small sample) and back-contact 24.9% (41 models). For a sense of scale, Fraunhofer ISE reports a weighted average of 22.7% for crystalline silicon modules from the top 10 manufacturers in late 2024.
Higher is better. Bars start at 18%.
Lower is better: the temperature coefficient of Pmax.
A panel's rated power is measured at standard test conditions, which every datasheet prints: 1000 W/m² of sunlight with the cells at 25°C. On a roof in full sun the cells run much hotter, and every panel loses power as it heats up. The temperature coefficient of Pmax, printed in %/°C, tells you how much.
How hot do the cells get? PV Education gives an approximate formula from a panel's nominal operating cell temperature (NOCT), measured at 800 W/m², 20°C air and 1 m/s wind, and notes that most modules have a NOCT of around 40 to 45°C. With that formula, a panel with a NOCT of 45°C in full sun (1000 W/m²) on a 35°C afternoon reaches about 66°C, roughly 41°C above the rating. Still air pushes it higher; wind brings it down.
Multiply that 41°C by the median temperature coefficients in our directory and the difference between technologies becomes clear. This is arithmetic from the datasheet figure, not a field measurement:
A bifacial panel has a glass or transparent back and makes power from light reflected onto its rear side. Bifaciality, printed as a percentage, says how strong the back is compared with the front. How much extra energy you actually get depends on the site: the height of the panels above the surface, the gap between rows and how reflective the ground or roof is. A panel mounted flat and close to a dark roof gains little from its back side.
In our directory, 141 of 160 current TOPCon models are bifacial, against 54 of 128 Mono PERC models and all 9 HJT models. Where makers print bifaciality, the median is 70% for PERC (29 models), 80% for TOPCon (100 models) and 90% for HJT (8 models).
Tell us about your site or your plan. An Ingro engineer reads it and calls you back within one business day with free advice, whether or not you ever buy from us.
Every panel loses a little output each year. A review of nearly 2,000 measured degradation rates by Jordan and Kurtz at NREL (Progress in Photovoltaics, 2013) found a median of 0.5% a year. Datasheets print the maker's own promise: a first-year loss and a yearly loss after that, and the share of rated power the panel should still give at the end of the warranty.
There is one known difference in the first months. A Fraunhofer ISE paper (Lohmüller et al., 2020) describes boron-oxygen light-induced degradation in conventional boron-doped p-type silicon, the wafer most PERC cells used, which makers suppress with an extra 'regeneration' step; the same paper shows gallium-doped p-type wafers let makers skip that step. This is one reason to read the first-year figure on a PERC datasheet carefully.
The warranty terms in our directory follow the technology quite closely:
There is no single best technology. The right choice depends on your roof, your budget and how the panels are mounted. As a rough guide, without naming any maker:
Can make sense where roof area is not the limit, the panels are mounted flat on the roof so bifacial gain is small, and the price difference is meaningful to you. Expect a larger roof area for the same kWp, more loss in heat, and, often, a 25-year rather than 30-year performance warranty.
The middle ground and the most widely listed option in our directory. More output per square metre than PERC, a lower median temperature coefficient, usually bifacial, and a 30-year performance warranty on almost every model that prints one. A sensible default to compare everything else against.
Worth a look where roof space is tight or the site is very hot, since both have the lowest median temperature coefficients and highest efficiencies in our data. Fewer makers offer them in India (4 makers list HJT and 5 list back-contact in our directory), so compare availability, price and after-sales support as well as the datasheet.
The technology label is a starting point. These are the lines worth comparing side by side, and the questions to ask an installer or maker:
6 questions
On the datasheet figures in our directory, TOPCon panels typically print higher efficiency (median 23.3% vs 21.3%), a lower temperature coefficient (median -0.29%/°C vs -0.35%/°C) and longer performance warranties. Whether that is worth the price depends on your roof area, mounting and quotes. Compare the datasheets of the exact panels you are offered.
It depends on the mounting. Panels raised well above a light-coloured roof, or on a carport or open structure, can gain from light reflected onto the back. Panels flush on a sloped or dark roof gain little. Most TOPCon panels in our directory are bifacial (141 of 160), so you will often be offered one either way.
It is the share of rated power a panel loses for each degree Celsius its cells run above 25°C, printed as %/°C (for example -0.29%/°C). On a hot roof the cells can run around 40°C above that, so a panel at -0.35%/°C loses about 14% and one at -0.29%/°C about 12%.
A kWp is a kWp at standard test conditions, whatever the technology. In real conditions, a panel with a lower temperature coefficient loses less power when hot, and a bifacial panel can add output from its back side if the mounting allows. How much that adds up to depends on your site, so treat any yield claim as an estimate and ask how it was calculated.
Panels keep working for decades but slowly lose output. A review of nearly 2,000 measured rates at NREL found a median loss of 0.5% a year. Datasheets print the maker's own figures: most TOPCon and HJT models in our directory carry a 30-year performance warranty, and Mono PERC models 25 to 30 years.
We don't recommend brands. Our solar panel directory lists current models from every maker we track, A to Z and not ranked, with the figures as printed on each datasheet, so you can compare the panels you have been quoted side by side.
Ask us a question about your home. Ingro also builds the smart EMS that runs solar, battery and backup inside home inverters.
Tell us about your site or your plan. An Ingro engineer reads it and calls you back within one business day with free advice, whether or not you ever buy from us.