Listed A–Z, not ranked · Reviewed November 2026
BESS cooling products
- Type
- Liquid chiller
- Cooling capacity
- 60 kW
- Refrigerant
- R410a
- Power supply
- NA
- Operating temperature
- -30–55 °C
- Ingress protection
- IP54 (Others) / IP56 (Electric box)
- Weight
- up to 500–600 kg
- Type
- Liquid chiller
- Cooling capacity
- NA
- Refrigerant
- R410A, R407C, R134A
- Power supply
- NA
- Operating temperature
- up to 50 °C
- Ingress protection
- NA
- Weight
- NA
- Type
- Liquid chiller
- Cooling capacity
- 8 kW
- Refrigerant
- R410a
- Power supply
- 230 V AC 1~ 50/60 Hz
- Operating temperature
- -25–55 °C
- Ingress protection
- IP 55 (internal, against the container, in both mounting methods)
- Weight
- 121 kg
- Type
- NA
- Cooling capacity
- 1–2 kW
- Refrigerant
- R513A
- Power supply
- 230 V AC 50/60 Hz ±10 %
- Operating temperature
- -40–55 °C
- Ingress protection
- IP 55 (towards the electrical enclosure) / IP 34 (towards the surroundings)
- Weight
- 26–32 kg
- Type
- NA
- Cooling capacity
- 3–5 kW
- Refrigerant
- R513A
- Power supply
- 230 V AC 50/60 Hz ±10 %
- Operating temperature
- -40–55 °C
- Ingress protection
- IP 55 (towards the electrical enclosure) / IP 34 (towards the surroundings)
- Weight
- 67–77 kg
EB 2.0 chillers 6.5-22 kW, listed for containerized BESS in the energy storage flyer
- Type
- Liquid chiller
- Cooling capacity
- 6.5–22 kW
- Refrigerant
- NA
- Power supply
- 400 V 3~ / 460 V 3~
- Operating temperature
- NA
- Ingress protection
- NA
- Weight
- NA
- Type
- Liquid chiller
- Cooling capacity
- 21–44 kW
- Refrigerant
- NA
- Power supply
- 400 / 460 V 3~
- Operating temperature
- NA
- Ingress protection
- NA
- Weight
- NA
- Type
- Liquid chiller
- Cooling capacity
- NA
- Refrigerant
- NA
- Power supply
- NA
- Operating temperature
- NA
- Ingress protection
- NA
- Weight
- NA
- Type
- Liquid chiller
- Cooling capacity
- 4.7–12.5 kW
- Refrigerant
- R134a (VLV 4), R513A (VLV 12)
- Power supply
- 570/800 V DC ±10 %
- Operating temperature
- -25–45 °C
- Ingress protection
- IP 54
- Weight
- 130–160 kg
- Type
- Liquid chiller
- Cooling capacity
- 60 kW
- Refrigerant
- R-134A, R-407C, R-410A, HFO and R-513A
- Power supply
- NA
- Operating temperature
- NA
- Ingress protection
- NA
- Weight
- NA
- Type
- Liquid chiller
- Cooling capacity
- 5 kW
- Refrigerant
- R-513A
- Power supply
- 380-415 V 3~ 50 Hz; 440-480 V 3~ 60 Hz
- Operating temperature
- -20–45 °C
- Ingress protection
- IP 24 / IP 54 (electrics)
- Weight
- 104 kg
- Type
- Liquid chiller
- Cooling capacity
- 6.7 kW
- Refrigerant
- R-513A
- Power supply
- 380-415 V 3~ 50 Hz; 440-480 V 3~ 60 Hz
- Operating temperature
- -20–45 °C
- Ingress protection
- IP 24 / IP 54 (electrics)
- Weight
- 109 kg
- Type
- Air conditioner / HVAC
- Cooling capacity
- NA
- Refrigerant
- R-236fa / R-227ea
- Power supply
- NA
- Operating temperature
- NA
- Ingress protection
- IP55
- Weight
- NA
- Type
- Air conditioner / HVAC
- Cooling capacity
- NA
- Refrigerant
- R134a / R407C
- Power supply
- NA
- Operating temperature
- NA
- Ingress protection
- IP54 / IP55 / IP56
- Weight
- NA
| Details | Add to plan, favourite | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| ATMOS | GWGR-BP600BHFBESS Chiller, 60 kW vertical packaged chiller | Liquid chiller | 60 kW | R410a | NA | -30–55 °C | IP54 (Others) / IP56 (Electric box) | up to 500–600 kg | ||
| Drycool Systems | BESS ChillersChiller for Battery Energy Storage Systems (BESS) | Liquid chiller | NA | R410A, R407C, R134A | NA | up to 50 °C | NA | NA | ||
| Pfannenberg | DMC 8.0Door-mounted chiller 8 kW for Battery Energy Storage Systems | Liquid chiller | 8 kW | R410a | 230 V AC 1~ 50/60 Hz | -25–55 °C | IP 55 (internal, against the container, in both mounting methods) | 121 kg | ||
| Pfannenberg | DTI 8201P | 8301P | 8401POutdoor cooling units 1000 - 2000 W | NA | 1–2 kW | R513A | 230 V AC 50/60 Hz ±10 % | -40–55 °C | IP 55 (towards the electrical enclosure) / IP 34 (towards the surroundings) | 26–32 kg | ||
| Pfannenberg | DTI 8601P | 8801P | 81001POutdoor cooling units 3000 - 5000 W | NA | 3–5 kW | R513A | 230 V AC 50/60 Hz ±10 % | -40–55 °C | IP 55 (towards the electrical enclosure) / IP 34 (towards the surroundings) | 67–77 kg | ||
| Pfannenberg | EB 2.0EB 2.0 chillers 6.5-22 kW, listed for containerized BESS in the energy storage flyer | Liquid chiller | 6.5–22 kW | NA | 400 V 3~ / 460 V 3~ | NA | NA | NA | ||
| Pfannenberg | EB 2.0 LargeEB 2.0 L chillers 21-44 kW, listed for containerized BESS | Liquid chiller | 21–44 kW | NA | 400 / 460 V 3~ | NA | NA | NA | ||
| Pfannenberg | IMC 8.0BESS chiller 8 kW, built-in cabinet installation | Liquid chiller | NA | NA | NA | NA | NA | NA | ||
| Pfannenberg | VLV 4 | VLV 12Off-grid chillers 800 V DC for Battery Energy Storage Systems | Liquid chiller | 4.7–12.5 kW | R134a (VLV 4), R513A (VLV 12) | 570/800 V DC ±10 % | -25–45 °C | IP 54 | 130–160 kg | ||
| Reynold India | BESS ChillerBattery energy storage system chiller, 60 kW | Liquid chiller | 60 kW | R-134A, R-407C, R-410A, HFO and R-513A | NA | NA | NA | NA | ||
| Rittal | SK 3334.440Blue e+ Hybrid IT chiller, outdoor design, 5 kW | Liquid chiller | 5 kW | R-513A | 380-415 V 3~ 50 Hz; 440-480 V 3~ 60 Hz | -20–45 °C | IP 24 / IP 54 (electrics) | 104 kg | ||
| Rittal | SK 3334.480Blue e+ Hybrid IT chiller, outdoor design, 6.7 kW | Liquid chiller | 6.7 kW | R-513A | 380-415 V 3~ 50 Hz; 440-480 V 3~ 60 Hz | -20–45 °C | IP 24 / IP 54 (electrics) | 109 kg | ||
| Tempcon | Industrial Air ConditionerIndustrial AC listed on the BESS cooling page | Air conditioner / HVAC | NA | R-236fa / R-227ea | NA | NA | IP55 | NA | ||
| Tempcon | Panel Air ConditionerWall-mounted and modular panel AC listed on the BESS cooling page | Air conditioner / HVAC | NA | R134a / R407C | NA | NA | IP54 / IP55 / IP56 | NA |
14 products
Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.
Is your company on this list? Add it, update your details or raise a concern →
New to BESS cooling? What they are, and what each spec means
Batteries age faster when they run hot, and Indian summers push enclosures well past the ideal range. BESS cooling comes as air conditioning units for air-cooled systems, or chillers that pump coolant through liquid-cooled racks. The companies below supply thermal management for battery storage in India.
What to compare before you choose
- Cooling capacity at your site's peak ambient temperature, not only at standard test conditions.
- Air or liquid cooling, and how evenly it keeps temperatures across the racks.
- Power drawn by the cooling itself, which counts against the system's round-trip efficiency.
- Dust and corrosion protection for the site's environment.
- Remote monitoring and alarms over Modbus or a similar protocol.
14 products from 6 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.