250 kVA DG sets (diesel and gas generator sets) in India

9 products from 7 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026

250 kVA is a common size for factories, hospitals, hotels and large office buildings. Sets are three-phase, usually with electronic governing; compare fuel consumption, dimensions and weight, which affect where the set can be placed.

250 kVA compared

A–Z by company, not ranked · NA: not published by the maker

FieldAshok LeylandLeypowerCPCB4+ Diesel Genset, LP15 to LP250Cummins IndiaL8.9 Series250 kVA, 200 kWe PrimeJakson GroupJSP-IVSilent diesel generating sets, radiator cooled, 7.5 to 750 kVAKirloskar Oil EnginesKG4-250WS NG1250 kVA Natural Gas GeneratorKirloskar Oil EnginesKG4-250WS1250 kVA Diesel GeneratorKirloskar Oil EnginesOptiprime 250 kVA250 kVA OptiprimeMahindra PowerolM10DR to M650DRAcoustic DG sets, 10 to 650 kVAOjus Power and TechnologiesOL seriesDiesel generators, 15 to 250 kVASudhir PowerCS D5P seriesCummins-powered silent diesel gensets (2023 brochure)
Output
Rating 15–250 kVA250 kVA7.5–750 kVA250 kVA250 kVA250 kVA10–650 kVA15–250 kVA7.5–2250 kVA
Power output 12–200 kWe200 kWe6–600 kWeNA200 kWe200 kWe8–520 kWe12–200 kWeNA
Printed ratings 15, 25, 30, 35, 40, 45, 60, 75, 82.5, 100, 125, 160, 180, 250 kVA250 kVA7.5, 10, 15, 18.5, 20, 25, 27.5, 30, 35, 40, 41, 50, 58.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 320, 380, 400, 500, 650, 750 kVA250 kVA250 kVA250 kVA10, 15, 20, 25, 30, 35, 40, 45, 50, 58.5, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 400, 500, 525, 650 kVA15, 20, 25, 30, 35, 40, 45, 60, 82.5, 100, 125, 160, 180, 250 kVA7.5, 10, 15, 20, 25, 30, 35, 40, 50, 62.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 275, 300, 320, 380, 400, 500, 600, 625, 650, 750, 810, 910, 1010, 1250, 1500, 1800, 2000, 2250 kVA
Rating basis NAPrimeNANAPrimePrimeNANAPrime
Output voltage NA415NA230 V415 (3ɸ)415 (3ɸ)230/415 (10 to 40 kVA), 415 (3 phase) aboveNANA
Frequency NA50 HzNA50 Hz50 Hz50 Hz50 HzNANA
Power factor NA0.8 (lagging)NANA0.80.80.8 laggingNANA
Phase NA3-phase1-phase, 3-phaseNA3-phase3-phase1-phase, 3-phaseNANA
Build
Fuel DieselDieselDieselGasDieselDieselNADieselNA
Engine H2G4DM15, P15G4DE25 and othersCummins 6L8.9TAA-G4X2.5-G5 to QSK19-G30 (and others)DV8TA NG16SL90ETA 4G24K1080ETA 4G1Mahindra M2155G1 and others; Perkins 2806FA-E18TAG1 and 2806FA-E18TAG2 for 400 to 650 kVAH2G4DM15, ALG184, P15G4DE25 and othersX1.3TAA-G1, X1.3TAA-G7
Alternator NAStamford S3L1D-K4NANANANACG/LS/EquivalentNANA
Enclosure AcousticAcousticAcousticAcousticAcousticAcousticAcousticNAAcoustic
Dimensions (L × W × H) 4700 × 1600 × 2020 mm (axes not stated)4300 × 1500 × 2025 mm (axes not stated)6800 × 2050 × 2860 mm (axes not stated)5100 × 2000 × 2410 mm (axes not stated)4750 × 1700 × 2005 mm (axes not stated)2520 × 2770 × 1570 mm (axes not stated)5800 × 2200 × 2300 mm (axes not stated)4700 × 1600 × 2020 mm (axes not stated)10450 × 3500 × 3800 mm (axes not stated)
Fuel tank capacity 55 to 34045085 to 980NANANA55 to 80050 to 340NA
Weight about 676–4500 kgabout 3850 kgabout 772–10156 kg5700 kg4100 kg5022 kg690–3920 kgabout 676–4500 kgNA
Certification
CPCB IV+ YesNAYesNAYesYesNAYesNA
Certifications and standards BS 5514, ISO 3046, ISO 8528IS/IEC 60034-1, ISO 8528, ISO 3046, IS 1460, ISO 9001, IS 13018NAISO 8528ISO 8528ISO 8528IS/IEC60034-1 (alternator)BS 5514, ISO 3046, ISO 8528NA
Performance
Governing class A0 (A1 on LP15)ISO 8528-5 G2G2/G3NANANAG2/G3A1 (OL 15, OL 20); A0 (OL 25 to OL 250)NA
Fuel consumption NA43.43 L/h at 75% loadNANANANANANANA
Noise level NA75 dBA at 1 m, 75% load, free fieldNA< 75 dB(A)<75 dBA<75 DBANANA75 dBA at 1 m
Controls
Controller GC 902 and GC 1206Cummins PowerStart PS0600NANANANAGC 1115 (10 to 200 kVA), GC 1116 (250 and 320 kVA), DSE7320 (400 to 650 kVA)GC 1207 (OL 15), DEIF SGC120 (OL 20), GC 1206 (OL 25 to OL 250)PS0600/1/2 (15-1010 kVA); PCC 3201 (1250-3750 kVA)
Support
Warranty NANA5C Warranty (5 years/ 5000 hours)NANA5-year standard warrantyStandard warranty of 2 Years/5000 Hours, 5 Years 5C warranty5 Years or 8000 hrs, T&C apply (OL 20: 2 years or 5000 hrs whichever occurs earlier)NA
Source
NoteSeries of 13 diesel sets from 15 kVA to 250 kVA; each set has its own specification page on the maker's site.Sheet prints the ratings, engine models, tank size and weight for 13 models.
Model codeLP15, LP25, LP30, LP35/40, LP45, LP60, LP75/82.5, LP100, LP125, LP160, LP180, LP250C250D5PJSP-IV 7.5 to JSP-IV 750NANANAM10DR to M650DROL 15, OL 20, OL 25, OL 30, OL 35/40, OL 45, OL 60, OL 82.5, OL 100, OL 125, OL 160, OL 180, OL 250CS 7.5 D5P to CS 2250 D5P
DatasheetSpec page of Ashok Leyland Leypower (opens the maker's site)Datasheet (PDF) of Cummins India L8.9 Series (opens the maker's site)Datasheet (PDF) of Jakson Group JSP-IV (opens the maker's site)Spec page of Kirloskar Oil Engines KG4-250WS NG1 (opens the maker's site)Spec page of Kirloskar Oil Engines KG4-250WS1 (opens the maker's site)Spec page of Kirloskar Oil Engines Optiprime 250 kVA (opens the maker's site)Datasheet (PDF) of Mahindra Powerol M10DR to M650DR (opens the maker's site)Datasheet (PDF) of Ojus Power and Technologies OL series (opens the maker's site)Datasheet (PDF) of Sudhir Power CS D5P series (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026
DetailsDetails of Ashok Leyland LeypowerDetails of Cummins India L8.9 SeriesDetails of Jakson Group JSP-IVDetails of Kirloskar Oil Engines KG4-250WS NG1Details of Kirloskar Oil Engines KG4-250WS1Details of Kirloskar Oil Engines Optiprime 250 kVADetails of Mahindra Powerol M10DR to M650DRDetails of Ojus Power and Technologies OL seriesDetails of Sudhir Power CS D5P series

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 9 products above, as printed.

  • Rating: 7.5 to 2250 kVA as printed (ranges included)
  • Power output: 6 to 600 kWe as printed (ranges included); 2 not published
  • Rating basis: Prime; 4 of 9 publish it
  • Fuel: 6 Diesel, 1 Gas; 2 not published
  • CPCB IV+: 5 of 9; 4 not published
  • Output voltage: 5 of 9 publish it; values in the table
  • Frequency: 50 Hz; 5 of 9 publish it
  • Power factor: 0.8 on 2, 0.8 (lagging) on 1, 0.8 lagging on 1; 5 not published
  • Governing class: 5 of 9 publish it; values in the table
  • Phase: 5 of 9 publish a list; 3-phase on 5, 1-phase on 2
  • Engine: 9 of 9 publish it; values in the table
  • Alternator: 2 of 9 publish it; values in the table
  • Enclosure: Acoustic; 8 of 9 publish it
  • Fuel consumption: 43.43 L/h at 75% load; 1 of 9 publishes it
  • Noise level: 5 of 9 publish it; values in the table
  • Controller: 5 of 9 publish it; values in the table
  • Dimensions (L × W × H): 9 of 9 publish it; values in the table
  • Fuel tank capacity: 450 on 1, 50 to 340 on 1, 55 to 340 on 1, 55 to 800 on 1, 85 to 980 on 1; 4 not published
  • Weight: 676 to 10156 kg as printed (ranges included); 1 not published (4 printed as approximate)
  • Warranty: 4 of 9 publish it; values in the table
  • Certifications and standards: 7 of 9 publish a list; ISO 8528 on 6, ISO 3046 on 3, BS 5514 on 2

Questions about 250 kVA DG sets (diesel and gas generator sets)

Which companies make 250 kVA DG sets (diesel and gas generator sets) in India?
7 companies list 9 products at this size: Ashok Leyland (Leypower); Cummins India (L8.9 Series); Jakson Group (JSP-IV); Kirloskar Oil Engines (KG4-250WS NG1, KG4-250WS1, Optiprime 250 kVA); Mahindra Powerol (M10DR to M650DR); Ojus Power and Technologies (OL series); Sudhir Power (CS D5P series). They are listed A–Z by company, not ranked.
How do these 250 kVA DG sets (diesel and gas generator sets) differ?
Rating: 7.5 to 2250 kVA as printed (ranges included). Power output: 6 to 600 kWe as printed (ranges included); 2 not published. Rating basis: Prime; 4 of 9 publish it. Fuel: 6 Diesel, 1 Gas; 2 not published. Counted from the 9 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 250 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.