Protection relays and switchgear products in India

Listed A–Z, not ranked · Reviewed November 2026

Protection relays and switchgear products

  • ABB India

    MNS

    Low voltage switchgear

    Type
    LV panel
    Voltage class
    690 V 3~, 750 V DC
    Rated current
    up to 6300 A
    Breaking capacity
    NA
    Standards
    IEC 61439-1/-2, IEC 61641, IEC 60529
    Communication
    NA
  • ABB India

    OVR T2 1N 40-275 P QS

    Type 2 surge protective device

    Type
    SPD
    Voltage class
    275 V
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    NA
  • ABB India

    Relion 615 series REF615

    Feeder protection and control

    Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    EN 60255-27, EN 60255-1, EN 60255-26, EN 50263
    Communication
    IEC 61850, IEC 60870-5-103, Modbus RTU, Modbus TCP, DNP3
  • ABB India

    SACE Emax 2

    Low voltage air circuit-breakers

    Type
    ACB
    Voltage class
    690 V
    Rated current
    250–6300 A
    Breaking capacity
    150 kA
    Standards
    IEC 60947, EN 60947, IEC 60947-2, IEC 60947-3, IEC 61000, UL 1066
    Communication
    Modbus (type not stated), Profibus, Modbus TCP, IEC 61850
  • ABB India

    SACE Tmax XT

    Low voltage molded case circuit-breakers

    Type
    MCCB
    Voltage class
    690 V
    Rated current
    16–1600 A
    Breaking capacity
    NA
    Standards
    IEC 60947-2
    Communication
    Modbus RTU, Profibus, IEC 61850
  • ABB India

    SafeRing / SafePlus 12-24 kV

    Gas-insulated ring main unit and compact switchgear

    Type
    RMU
    Voltage class
    12 kV, 17.5 kV, 24 kV
    Rated current
    630 A
    Breaking capacity
    25 kA
    Standards
    IEC 62271-1, IEC 62271-100, IEC 62271-102, IEC 62271-103, IEC 62271-105, IEC 62271-200, IEC 60529
    Communication
    IEC 61850, Modbus TCP, Modbus (type not stated)
  • Type
    MCB
    Voltage class
    230/400 V AC
    Rated current
    0.5–63 A
    Breaking capacity
    15 kA
    Standards
    IEC/EN 60898-1, IEC/EN 60947-2, UL 1077
    Communication
    NA
  • ABB India

    UniGear ZS1

    Air-insulated medium voltage switchgear

    Type
    MV panel
    Voltage class
    7.2 kV, 12 kV, 17.5 kV, 24 kV
    Rated current
    630–4000 A
    Breaking capacity
    NA
    Standards
    CEI 62271-1, CEI 62271-200, CEI 62271-102, CEI 62271-100, CEI 60071-2, CEI 62271-106, CEI 62271-103, CEI 60529
    Communication
    NA
  • ABB India

    VD4

    Medium voltage vacuum circuit-breakers

    Type
    VCB
    Voltage class
    12 kV to 24 kV
    Rated current
    630–2500 A
    Breaking capacity
    31.5 kA
    Standards
    IEC 62271-100, CEI 17-1 (File 1375)
    Communication
    NA
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-22-1, IEC 60255-22-2, IEC 60255-22-4, IEC 60255-26, IEC 60255-22-7, IEC 60255-22-3, IEC 60255-11, IEC 60255-25, IEC 60255-27, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-78, IEC 60068-2-14, IEC 60068-2-30, IEC 60529, IEC 60255-21-1, IEC 60255-21-2, IEC 60255-21-3, EN 50178
    Communication
    IEC 60870-5-103, Modbus (type not stated), DNP3, RS485
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-26, IEC 60255-27, IEC 60255-1, IEC 60255-21-1, IEC 60255-21-2, IEC 60255-21-3, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-78, IEC 60068-2-30, IEC 60068-2-14, IEC 60529
    Communication
    IEC 60870-5-103, IEC 61850, Ethernet, RS485
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    IEC 60870-5-103
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    None
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    NA
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    IEC 61850, IEC 60870-5-103, Modbus TCP, IEC 60870-5-104, Ethernet, RS485
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    IEC 60870-5-103, Modbus (type not stated)
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    IEC 60870-5-103, Modbus (type not stated), IEC 60870-5-104, IEC 61850
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    IEC 60870-5-103
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    IEC 60870-5-103, Modbus (type not stated), IEC 61850, Ethernet, RS485
  • Type
    Numerical relay
    Voltage class
    NA
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-26, IEC 60255-27, IEC 60255-21-1, IEC 60255-21-2, IEC 60255-21-3, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-78, IEC 60068-2-14, IEC 60068-2-30, IEC 60529, EN 50178
    Communication
    IEC 60870-5-103, Modbus RTU, Modbus TCP, IEC 60870-5-104, IEC 61850, Ethernet, RS485
  • BCH Electric

    MCB

    Miniature circuit breaker, 0.5 A to 63 A, B and C curve

    Type
    MCB
    Voltage class
    NA
    Rated current
    0.5–63 A
    Breaking capacity
    10 kA
    Standards
    IS/IEC 60898-1 (6A - 63A), IS/IEC 60947-2 (0.5A - 5A)
    Communication
    NA
  • BCH Electric

    Resilient MCCB

    3 pole MCCB, thermal magnetic and microprocessor (LSIG) release

    Type
    MCCB
    Voltage class
    415 V
    Rated current
    16–630 A
    Breaking capacity
    50 kA
    Standards
    IS/IEC60947 - 2
    Communication
    NA
  • BCH Electric

    TemPower2 ACB

    Double-break air circuit breaker, standard and high fault series

    Type
    ACB
    Voltage class
    690 V
    Rated current
    800–6300 A
    Breaking capacity
    100 kA
    Standards
    IEC 60947-2, JIS C 8201-2-1 Ann.1 Ann.2
    Communication
    NA
  • BCH Electric

    Ultra Power ACB

    Air circuit breaker, 3 frame sizes, BTX protection and control unit

    Type
    ACB
    Voltage class
    upto 690V AC
    Rated current
    800–6300 A
    Breaking capacity
    100 kA
    Standards
    IS / IEC 60947 (Part-2), EN 60947-2, IEC 60947-2
    Communication
    Modbus (type not stated), Profibus
  • BCH Electric

    X-Range MCCB (XF, XG, XA, XB)

    3 and 4 pole MCCB, thermal magnetic and microprocessor (LSI / LSIG) release

    Type
    MCCB
    Voltage class
    NA
    Rated current
    16–1250 A
    Breaking capacity
    50 kA
    Standards
    IS/IEC-60947-2
    Communication
    NA
  • BCH Electric

    XF Range MCCB

    3 pole MCCB, thermal magnetic and microprocessor release, motor back-up versions

    Type
    MCCB
    Voltage class
    415 V
    Rated current
    16–630 A
    Breaking capacity
    50 kA
    Standards
    IS/IEC60947 - 2
    Communication
    NA
  • Bush Electromech & Engineering

    12-33kV Control and Relay Panel (CRP)

    Indoor control and relay panels, simplex and duplex, feeder, transformer, bus coupler, bus bar differential and capacitor protection

    Type
    MV panel
    Voltage class
    11 kV to 33 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IS 8623, IEC 60439
    Communication
    NA
  • Bush Electromech & Engineering

    12kV Fixed VCB Panel

    Indoor/outdoor fixed type VCB panel with vacuum interrupters

    Type
    MV panel
    Voltage class
    12 kV
    Rated current
    400–630 A
    Breaking capacity
    NA
    Standards
    NA
    Communication
    NA
  • Bush Electromech & Engineering

    12kV Indoor VCB Panel

    Air insulated VCB switchboard with horizontal draw-out breakers

    Type
    MV panel
    Voltage class
    12 kV
    Rated current
    630–1600 A
    Breaking capacity
    NA
    Standards
    NA
    Communication
    NA
  • Bush Electromech & Engineering

    12kV Outdoor VCB Panel

    Air insulated outdoor VCB switchboard with horizontal draw-out breakers

    Type
    MV panel
    Voltage class
    12 kV
    Rated current
    630–1600 A
    Breaking capacity
    NA
    Standards
    NA
    Communication
    NA
  • Bush Electromech & Engineering

    12kV Outdoor VCB Panel (side cable)

    Air insulated outdoor VCB switchboard, side cable version

    Type
    MV panel
    Voltage class
    12 kV
    Rated current
    630–1250 A
    Breaking capacity
    NA
    Standards
    NA
    Communication
    NA
  • Bush Electromech & Engineering

    22-33kV Indoor VCB Panel

    Indoor draw-out air insulated VCB switchboard

    Type
    MV panel
    Voltage class
    33 kV
    Rated current
    630–1600 A
    Breaking capacity
    31.5 kA
    Standards
    IEC 62271-100, IEC 62271-200, IS 3427-1997
    Communication
    NA
  • Bush Electromech & Engineering

    22-33kV Outdoor VCB Panel

    Outdoor draw-out air insulated VCB switchboard

    Type
    MV panel
    Voltage class
    33 kV
    Rated current
    630–1600 A
    Breaking capacity
    31.5 kA
    Standards
    IEC 62271-100, IEC 62271-200, IS 3427-1997
    Communication
    NA
  • GK Expertise

    Auto Transformer Relay

    Numerical Auto Transformer Protection Relay

    Type
    Numerical relay
    Voltage class
    25 kV, 2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-1, IEC 60255-26, IEC 60255-27
    Communication
    IEC 61850, IEC 60870-5-103, RS485
  • GK Expertise

    Capacitor Bank Relay

    Numerical Capacitor Bank Protection Relay

    Type
    Numerical relay
    Voltage class
    25 kV, 2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-1, IEC 60255-26, IEC 60255-27
    Communication
    IEC 61850, IEC 60870-5-103, RS485
  • Type
    Numerical relay
    Voltage class
    25 kV, 2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-1, IEC 60255-26, IEC 60255-27
    Communication
    IEC 61850, IEC 60870-5-103, RS485
  • Type
    Numerical relay
    Voltage class
    25 kV, 2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-1, IEC 60255-26, IEC 60255-27
    Communication
    IEC 61850, IEC 60870-5-103, RS485
  • Type
    Numerical relay
    Voltage class
    25 kV, 2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-1, IEC 60255-26, IEC 60255-27
    Communication
    IEC 61850, IEC 60870-5-103, RS485
  • GK Expertise

    Panto Flashover Relay

    Numerical Panto Flashover Protection Relay

    Type
    Numerical relay
    Voltage class
    25 kV, 2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-1, IEC 60255-26, IEC 60255-27
    Communication
    IEC 61850, IEC 60870-5-103, RS485
  • GK Expertise

    Scott Connected Transformer Panel

    Scott Connected Transformer Protection Control & Relay Panel

    Type
    MV panel
    Voltage class
    2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    IEC 60870-5-103, IEC 61850
  • GK Expertise

    Sectioning & Paralleling Panel

    Sectioning & Paralleling Control & Relay Panel

    Type
    MV panel
    Voltage class
    2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    NA
    Communication
    IEC 60870-5-103, IEC 61850
  • GK Expertise

    Transformer Differential Relay

    Numerical Transformer Differential Protection Relay

    Type
    Numerical relay
    Voltage class
    25 kV, 2X25 kV
    Rated current
    NA
    Breaking capacity
    NA
    Standards
    IEC 60255-1, IEC 60255-26, IEC 60255-27
    Communication
    IEC 61850, IEC 60870-5-103, RS485
  • Type
    MCCB
    Voltage class
    415 V AC
    Rated current
    1000–1600 A
    Breaking capacity
    50 kA
    Standards
    IEC 60947-2, IS 13947-2
    Communication
    NA
  • Type
    MCCB
    Voltage class
    415 V AC
    Rated current
    25–250 A
    Breaking capacity
    50 kA
    Standards
    IEC 60947-2, IS 13947-2
    Communication
    NA
  • Type
    MCCB
    Voltage class
    415 V AC
    Rated current
    25–160 A
    Breaking capacity
    25 kA
    Standards
    IEC 60947-2, IS 13947-2
    Communication
    NA
  • Type
    MCCB
    Voltage class
    690 V AC
    Rated current
    16–125 A
    Breaking capacity
    55 kA
    Standards
    IEC 60947-2, IS 13947-2
    Communication
    NA
  • Type
    MCCB
    Voltage class
    690 V AC
    Rated current
    150–250 A
    Breaking capacity
    55 kA
    Standards
    IEC 60947-2, IS 13947-2
    Communication
    NA
  • Type
    MCCB
    Voltage class
    690 V AC
    Rated current
    300–400 A
    Breaking capacity
    85 kA
    Standards
    IEC 60947-2, IS 13947-2
    Communication
    NA
  • Type
    MCCB
    Voltage class
    690 V AC
    Rated current
    500–630 A
    Breaking capacity
    85 kA
    Standards
    IEC 60947-2, IS 13947-2
    Communication
    NA
  • Type
    MCCB
    Voltage class
    690 V AC
    Rated current
    700–800 A
    Breaking capacity
    85 kA
    Standards
    IEC 60947-2, IS 13947-2
    Communication
    NA
Showing 50 of 118

118 products

Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.

Protection relay and switchgear manufacturers in India21 companies in 10 cities, with profiles and websites.Companies →

New to protection relays and switchgear? What they are, and what each spec means

Switchgear connects and disconnects equipment, and protection relays trip it when a fault appears. Every battery, solar plant and DG set connects to the site through them. The companies below make LV and MV switchgear and relays in India.

What to compare before you choose

  • Voltage and current ratings, and the fault level at your connection point.
  • Relay functions needed for solar and storage, such as reverse power and anti-islanding.
  • Communication: IEC 61850 or Modbus for breaker status and relay events.
  • Type-test certificates and compliance with your utility's requirements.

118 products from 13 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.