HBL Engineering GSESS

Listed A–Z, not ranked · Reviewed November 2026

Grid Scale Energy Storage System · BESS containers by HBL EngineeringLegacy

As printed in the spec page, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.

Rating

Rated energy
240–1008 kWh
Rated power
250–1000 kW
Charge/discharge rate
NA
Duration
NA
PCS included
NA
Cooling
NA

Battery

Cell capacity
NA
Chemistry
LFP
DC voltage range
NA
Cycle life
2000 cycles

Electrical

AC voltage
NA
AC frequency
50
Round-trip efficiency
NA
Efficiency measured
NA

Physical

Size (mm)
NA
Weight
NA
Enclosure rating
NA

Environment

Operating temperature
-20–60 °C
Max altitude
NA

Safety

Fire suppression
NA
Certifications
NA
Size:
6 sizes
Model code:
LFP 480V-500, LFP 480V-1000, LFP 720V-1400
Checked:
November 2026, against the spec page

Note

Three sizes: 250 kW / 240 kWh, 500 kW / 480 kWh and 1000 kW / 1008 kWh.

Full datasheet

Every row the maker prints, copied as written, read 2026-11-15.

Overview

Model
Grid Scale240 KWh Battery (250 KW tab): LFP 480V-500; 480 KWh Battery (500 KW tab): LFP 480V-1000; 1 MWh Battery (1000 KW tab): LFP 720V-1400
Product line
Energy Storage Systems (ESS) » Grid Scale250 KW; 500 KW; 1000 KW
Description
Energy storage becomes relevant to optimize generation and consumption of energy at different points of time and also ensure uninterrupted & quality power supply. ESS is an application, wherein Energy generated at one time is used at another time.

Battery

Cell type
Lithium iron phosphate(LFP); Prismatic
Battery rating
240 KWh Battery (250 KW tab): 480V-500AH; 480 KWh Battery (500 KW tab): 480V-1000AH; 1 MWh Battery (1000 KW tab): 720V-1400AH
Module rating
48V-100 Ah
Module size
480 x 350 x 222 ( W x D x H)
Modules per rack
5
Battery clusters
240 KWh Battery (250 KW tab): 10; 480 KWh Battery (500 KW tab): 20; 1 MWh Battery (1000 KW tab): 42
Rated energy
240 KWh Battery (250 KW tab): 240; 480 KWh Battery (500 KW tab): 480; 1 MWh Battery (1000 KW tab): 1008
Charging voltage
240 KWh Battery (250 KW tab): 547 Volt; 480 KWh Battery (500 KW tab): 547 Volt; 1 MWh Battery (1000 KW tab): 821 Volt
End (cut-off) voltage
240 KWh Battery (250 KW tab): 375 Volt; 480 KWh Battery (500 KW tab): 375 Volt; 1 MWh Battery (1000 KW tab): 562 Volt
Charge/discharge current
240 KWh Battery (250 KW tab): 100 Amps / 100 Amps; 480 KWh Battery (500 KW tab): 200 Amps; 1 MWh Battery (1000 KW tab): 280 Amps / 280 Amps
Cycle life
>2000 Cycles (at 20-25°C)
Battery operating temperature
-/0°C to 45°C/-20°C to +60°C/-20°C to +25°C

Power and grid

Rated AC power
250KW
Max input power
As per Inverter Rating
PCS DC voltage range
360/480
AC voltage
400V, 50 Hz +/-2%,(+10%,-20% In Grid Synchronised mode
AC voltage range
+10% & -20 % VAC
Phases / wiring
3 Phase
AC frequency range
+5% & -5% Hz
Voltage regulation
+/- 2% ( In stand alone mode)
Frequency regulation (standalone)
0.5 Hz
PCS efficiency
90%
PCS cooling
Temperature controlled forced cooling
Grid charger efficiency
Upto 85%
Power factor
0.8 lag to Unity
Current distortion (THD)
<5%
Overload
110%- 60 Sec, 125%-30 Sec, 150%-5 Sec
Grid synchronisation
Provided
Parallel operation with grid/DG
Provided
Export to grid
Enable/ Disable/ User settable
Grid charging
Enable/ Disable/ User settable
Auto bypass
Provided

Solar and generator

Solar (MPPT) power
Same as Inverter rating
Solar (MPPT) voltage range
515/623330/495
Solar (MPPT) max voltage
620/750
MPPT inputs
1
Solar charge controller
MPPT
Solar charger topology
Buck type
Solar charger efficiency
≥ 94%
Battery types supported
VRLA/LMLA / LITHIUM / NICAD/ FLOW BATTERIES

Environment

PCS operating temperature
0-55 Deg.c without derating.
Operating humidity
5%≤RH≤85%
PCS humidity
Max. 95 % Non condensing
PCS max altitude
1000 M above sea level

Physical

Rack size
650 x 500 x 1680 ( W x D x H)
Weight
240 KWh Battery (250 KW tab): ~60 Kgs / 3825 Kgs; 480 KWh Battery (500 KW tab): 60 Kgs / 7000 Kgs; 1 MWh Battery (1000 KW tab): ~60 Kgs / 28000 Kgs
PCS enclosure rating
IP 21
Installation
Floor Stand by – Tower typeFrom Rear bottom

Safety

Battery protection
Reverse polarity, Over/Under Voltage, Current Limit240 KWh Battery (250 KW tab): Over Voltage, Under Voltage, Short Circuit, Over Temperature; 480 KWh Battery (500 KW tab): Over/ Under Voltage, Short Circuit, Over Temperature; 1 MWh Battery (1000 KW tab): Over/, Under Voltage, Short Circuit, Over Temperature
Grid-side protection
Over/Under Voltage, Over/Under Frequency, Surge Protection –D
Load-side protection
Over load, Short circuit
PV-side protection
Reverse Polarity, Surge Protection ( class D)
System protection
Over Temperature, Emergency Stop.
PCS standards
IEC 62116, IEC 61727, IEC 61683, IEC 60068 ( 1,2, 14, 30), EN 50530

Communication

Communication
RS 485 Based monitoring showing all parameters through MODBUSEasy to connect GPRS based Xenius module for remote monitoring of all parameters , ( 5 years data charge + SIM included for 3 phase) as well as remote controlling.Data logging in micro SD card, All parameters can be logged in Micro SD card as per date & time. Logged parameters can be viewed / saved through Laptop / PC
Display
Graphical LCD with back lit (128 x 64)Membrane Keypad for setting inputsMains ON, Alarm. Buzzer mute
Displayed: battery
Voltage, Current, Cumulative Import Energy
Displayed: grid
Phase voltage, Frequency, Power factor, Reactive Power
Displayed: load
Phase voltage/ current, Frequency, Power, Power Factor, Avg.
Displayed: PV
Voltage, MPPT charger output Amps, Power, Energy cumulative
Displayed: system
Mode of operation, active faults, Heat sink, IGBT Temperature

Features

Application
Grid operators & utilities (power quality): Power Reliability; Peak Shaving and Load Leveling; Electric energy time-shift (arbitrage); Electric supply capacity; Regulation; Spinning, non-spinning and supplemental reserves; Voltage support; Black start; Load following/Ramping up of renewables; Transmission upgrade deferral; Transmission congestion relief; Distribution upgrade deferral and voltage support. Customer ('Behind-the-meter') applications: Time-of-Use Bill ManagementCommercial and Industrial Applications; Grid Scale/ Utility Applications; Arbitrage; Firm Capacity or Peaking Capacity; Operating Reserves and Ancillary Services; Transmission and Distribution Upgrade Deferrals; Black Start

HBL Engineering GSESS, in short

The HBL Engineering GSESS is a container BESS rated 250 kW.

Questions about the HBL Engineering GSESS

What are the main specifications of the HBL Engineering GSESS?
Rated 250 kW. As printed on HBL Engineering's spec page (checked November 2026); the full list is on this page.
Where can I find the HBL Engineering GSESS spec page?
HBL Engineering publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
Who makes the HBL Engineering GSESS?
HBL Engineering, with its head office in Hyderabad.

Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.

Values as HBL Engineering prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with HBL Engineering. Product and company names are trademarks of their owners, used only to identify the product.

Not sure what to buy? Ask us what's compatible and what size fits your site.