Specifications
As printed in the spec page, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.
Rating
- Rated energy
- 240–1008 kWh
- Rated power
- 250–1000 kW
- Charge/discharge rate
- NA
- Duration
- NA
- PCS included
- NA
- Cooling
- NA
Battery
- Cell capacity
- NA
- Chemistry
- LFP
- DC voltage range
- NA
- Cycle life
- 2000 cycles
Electrical
- AC voltage
- NA
- AC frequency
- 50
- Round-trip efficiency
- NA
- Efficiency measured
- NA
Physical
- Size (mm)
- NA
- Weight
- NA
- Enclosure rating
- NA
Environment
- Operating temperature
- -20–60 °C
- Max altitude
- NA
Safety
- Fire suppression
- NA
- Certifications
- NA
- Size:
- 6 sizes
- Model code:
- LFP 480V-500, LFP 480V-1000, LFP 720V-1400
- Checked:
- November 2026, against the spec page
Note
Three sizes: 250 kW / 240 kWh, 500 kW / 480 kWh and 1000 kW / 1008 kWh.
Full datasheet
Every row the maker prints, copied as written, read 2026-11-15.
Overview
- Model
- Grid Scale240 KWh Battery (250 KW tab): LFP 480V-500; 480 KWh Battery (500 KW tab): LFP 480V-1000; 1 MWh Battery (1000 KW tab): LFP 720V-1400
- Product line
- Energy Storage Systems (ESS) » Grid Scale250 KW; 500 KW; 1000 KW
- Description
- Energy storage becomes relevant to optimize generation and consumption of energy at different points of time and also ensure uninterrupted & quality power supply. ESS is an application, wherein Energy generated at one time is used at another time.
Battery
- Cell type
- Lithium iron phosphate(LFP); Prismatic
- Battery rating
- 240 KWh Battery (250 KW tab): 480V-500AH; 480 KWh Battery (500 KW tab): 480V-1000AH; 1 MWh Battery (1000 KW tab): 720V-1400AH
- Module rating
- 48V-100 Ah
- Module size
- 480 x 350 x 222 ( W x D x H)
- Modules per rack
- 5
- Battery clusters
- 240 KWh Battery (250 KW tab): 10; 480 KWh Battery (500 KW tab): 20; 1 MWh Battery (1000 KW tab): 42
- Rated energy
- 240 KWh Battery (250 KW tab): 240; 480 KWh Battery (500 KW tab): 480; 1 MWh Battery (1000 KW tab): 1008
- Charging voltage
- 240 KWh Battery (250 KW tab): 547 Volt; 480 KWh Battery (500 KW tab): 547 Volt; 1 MWh Battery (1000 KW tab): 821 Volt
- End (cut-off) voltage
- 240 KWh Battery (250 KW tab): 375 Volt; 480 KWh Battery (500 KW tab): 375 Volt; 1 MWh Battery (1000 KW tab): 562 Volt
- Charge/discharge current
- 240 KWh Battery (250 KW tab): 100 Amps / 100 Amps; 480 KWh Battery (500 KW tab): 200 Amps; 1 MWh Battery (1000 KW tab): 280 Amps / 280 Amps
- Cycle life
- >2000 Cycles (at 20-25°C)
- Battery operating temperature
- -/0°C to 45°C/-20°C to +60°C/-20°C to +25°C
Power and grid
- Rated AC power
- 250KW
- Max input power
- As per Inverter Rating
- PCS DC voltage range
- 360/480
- AC voltage
- 400V, 50 Hz +/-2%,(+10%,-20% In Grid Synchronised mode
- AC voltage range
- +10% & -20 % VAC
- Phases / wiring
- 3 Phase
- AC frequency range
- +5% & -5% Hz
- Voltage regulation
- +/- 2% ( In stand alone mode)
- Frequency regulation (standalone)
- 0.5 Hz
- PCS efficiency
- 90%
- PCS cooling
- Temperature controlled forced cooling
- Grid charger efficiency
- Upto 85%
- Power factor
- 0.8 lag to Unity
- Current distortion (THD)
- <5%
- Overload
- 110%- 60 Sec, 125%-30 Sec, 150%-5 Sec
- Grid synchronisation
- Provided
- Parallel operation with grid/DG
- Provided
- Export to grid
- Enable/ Disable/ User settable
- Grid charging
- Enable/ Disable/ User settable
- Auto bypass
- Provided
Solar and generator
- Solar (MPPT) power
- Same as Inverter rating
- Solar (MPPT) voltage range
- 515/623330/495
- Solar (MPPT) max voltage
- 620/750
- MPPT inputs
- 1
- Solar charge controller
- MPPT
- Solar charger topology
- Buck type
- Solar charger efficiency
- ≥ 94%
- Battery types supported
- VRLA/LMLA / LITHIUM / NICAD/ FLOW BATTERIES
Environment
- PCS operating temperature
- 0-55 Deg.c without derating.
- Operating humidity
- 5%≤RH≤85%
- PCS humidity
- Max. 95 % Non condensing
- PCS max altitude
- 1000 M above sea level
Physical
- Rack size
- 650 x 500 x 1680 ( W x D x H)
- Weight
- 240 KWh Battery (250 KW tab): ~60 Kgs / 3825 Kgs; 480 KWh Battery (500 KW tab): 60 Kgs / 7000 Kgs; 1 MWh Battery (1000 KW tab): ~60 Kgs / 28000 Kgs
- PCS enclosure rating
- IP 21
- Installation
- Floor Stand by – Tower typeFrom Rear bottom
Safety
- Battery protection
- Reverse polarity, Over/Under Voltage, Current Limit240 KWh Battery (250 KW tab): Over Voltage, Under Voltage, Short Circuit, Over Temperature; 480 KWh Battery (500 KW tab): Over/ Under Voltage, Short Circuit, Over Temperature; 1 MWh Battery (1000 KW tab): Over/, Under Voltage, Short Circuit, Over Temperature
- Grid-side protection
- Over/Under Voltage, Over/Under Frequency, Surge Protection –D
- Load-side protection
- Over load, Short circuit
- PV-side protection
- Reverse Polarity, Surge Protection ( class D)
- System protection
- Over Temperature, Emergency Stop.
- PCS standards
- IEC 62116, IEC 61727, IEC 61683, IEC 60068 ( 1,2, 14, 30), EN 50530
Communication
- Communication
- RS 485 Based monitoring showing all parameters through MODBUSEasy to connect GPRS based Xenius module for remote monitoring of all parameters , ( 5 years data charge + SIM included for 3 phase) as well as remote controlling.Data logging in micro SD card, All parameters can be logged in Micro SD card as per date & time. Logged parameters can be viewed / saved through Laptop / PC
- Display
- Graphical LCD with back lit (128 x 64)Membrane Keypad for setting inputsMains ON, Alarm. Buzzer mute
- Displayed: battery
- Voltage, Current, Cumulative Import Energy
- Displayed: grid
- Phase voltage, Frequency, Power factor, Reactive Power
- Displayed: load
- Phase voltage/ current, Frequency, Power, Power Factor, Avg.
- Displayed: PV
- Voltage, MPPT charger output Amps, Power, Energy cumulative
- Displayed: system
- Mode of operation, active faults, Heat sink, IGBT Temperature
Features
- Application
- Grid operators & utilities (power quality): Power Reliability; Peak Shaving and Load Leveling; Electric energy time-shift (arbitrage); Electric supply capacity; Regulation; Spinning, non-spinning and supplemental reserves; Voltage support; Black start; Load following/Ramping up of renewables; Transmission upgrade deferral; Transmission congestion relief; Distribution upgrade deferral and voltage support. Customer ('Behind-the-meter') applications: Time-of-Use Bill ManagementCommercial and Industrial Applications; Grid Scale/ Utility Applications; Arbitrage; Firm Capacity or Peaking Capacity; Operating Reserves and Ancillary Services; Transmission and Distribution Upgrade Deferrals; Black Start
HBL Engineering GSESS, in short
The HBL Engineering GSESS is a container BESS rated 250 kW.
Questions about the HBL Engineering GSESS
- What are the main specifications of the HBL Engineering GSESS?
- Rated 250 kW. As printed on HBL Engineering's spec page (checked November 2026); the full list is on this page.
- Where can I find the HBL Engineering GSESS spec page?
- HBL Engineering publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
- Who makes the HBL Engineering GSESS?
- HBL Engineering, with its head office in Hyderabad.
Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.
Values as HBL Engineering prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with HBL Engineering. Product and company names are trademarks of their owners, used only to identify the product.