Listed A–Z, not ranked · Reviewed November 2026
Power Conversion System, 6 MVA power solution for BESS (liquid cooled, up to 1500 Vdc) · PCS by Hitachi Energy India
Specifications
Datasheet on publisher.hitachienergy.com(opens in a new tab)Product pageon hitachienergy.com (opens in a new tab)
As printed in the datasheet, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.
AC side
- Rated power
- 4839–5118 kW
- Printed ratings
- 4839, 4980, 5118 kW
- Nominal AC voltage
- 690–730 V
- Grid frequency
- NA
DC side
- DC voltage range
- 987–1500 V
- Max DC current
- NA
Performance
- Max efficiency
- 98.82 %
Build
- Type
- NA
- Cooling
- Liquid
- Ingress protection
- IP65
- Operating temperature
- -25–55 °C
- Weight
- about 8000 kg
- MV transformer built in
- No
- Communication
- NA
Grid functions
- Off-grid / black start
- Yes
- Grid-forming
- Yes
Certification
- Certifications
- IEC 62477, IEC 62109-1, IEC 62109-2, IEC 61000-3-4, IEC 61000-3-11, IEC 61000-3-12, IEC 61000-6-4, CE Marking
- Model code:
- PCS-WD4-V690, PCS-WD4-V710, PCS-WD4-V730
- Checked:
- November 2026, against the datasheet
Note
Rated at 50 °C; 5376–5688 kW at 35 °C.
Full datasheet
Every row the maker prints, copied as written, read 2026-11-15.
Overview
- Product
- Power Conversion System (PCS) WD46 MVA power solution
- Models
- PCS-WD4-V690; PCS-WD4-V710; PCS-WD4-V730
- Description
- Bidirectional plug and play converter, optimized for BESS and DC-coupled hybrid systems integration into complex electrical grids, and compatible with leading battery manufacturers.Fast response and advanced active power management for highly demanding environments (e.g. ramp rate, frequency response).Flexible DC bus connection ensuring efficient project sizing, especially important for large-scale storage projects.Seamless integration between Hitachi Energy’s power plant controller (PPC) and the battery management system (BMS) from the battery manufacturer.PCS is a high power density power conversion system for utility-scale battery energy storage systems (up to 1500 VDC). It is optimized for BESS integration into complex electrical grids and is based on our best-in-class liquid cooled power conversion platform, enabling greater scalability and efficiency.(hitachienergy.com)
DC side
- SoC voltage range at full power (Vdc)
- PCS-WD4-V690: 987-1500; PCS-WD4-V710: 1016-1500; PCS-WD4-V730: 1044-1500
- Max. DC voltage (Vdc)
- 1550
- Max. input current (A)
- 3 x 2000
- Withstand current (A)
- 250 kA maximum available fault current, 5.58 MA2s pre-arcing energy (without internal fuse); 250 kA maximum available fault current (with internal fuse); Time constant τ = L/R (tau) of the DC circuit must be between 0,3 ms and 3 ms
- Number of DC inputs
- 3
AC side
- AC output power at 35 °C (kVA/kW)
- PCS-WD4-V690: 5376; PCS-WD4-V710: 5532; PCS-WD4-V730: 5688
- AC output power at 50 °C (kVA/kW)
- PCS-WD4-V690: 4839; PCS-WD4-V710: 4980; PCS-WD4-V730: 5118
- Nominal AC voltage (V)
- PCS-WD4-V690: 690; PCS-WD4-V710: 710; PCS-WD4-V730: 730
- Max. AC current at 35 °C
- 3 x 1500
- Power factor
- Adjustable
- Current harmonic distortion (THDi)
- <3%
Efficiency
- Max. / Euroeta / CEC efficiency (%)
- PCS-WD4-V690: 98.8 / 98.41 / 98.4; PCS-WD4-V710: 98.82 / 98.44 / 98.44; PCS-WD4-V730: 98.82 / 98.46 / 98.46
Protection
- DC protection and disconnection
- DC load break switchOptional
- AC protection and disconnection
- AC circuit breaker
- Overvoltage protection
- Class II / type 2 (optional class I + II / type 1)
- Ground fault / insulation monitoring
- YesYes
Environment
- Operating temperature
- From -13ºF to 131ºF (-25ºC to 55ºC), derating < 5ºF (-15ºC) and >95ºF (35ºC)
- Storage temperature
- 5ºF / 149ºF (-15ºC / 65ºC) coolant filled; -13ºF / 149ºF (-25ºC / 65ºC) without coolant
- Relative humidity
- 100%
- Storage humidity
- From 5% to 85%
- Max. altitude
- 4000 masl, derating >1000masl
- Ingress protection
- IP65
- Cooling
- Liquid cooling system
Physical
- Dimensions (W × D × H)
- 6977 x 1100 x 2535 mm
- Weight
- ~8 tn
Certifications
- Certifications and standards
- IEC 62477; IEC 62109-1, IEC 62109-2, IEC62109; IEC 61000-3-4, IEC 61000-3-11, IEC 61000-3-12, IEC 61000-6-4; CE Marking; Grid code certificates available on request
Features
- Features
- System Strength; Synthetic Inertia; Grid Forming; Power Quality; Black StartAbility to perform in high altitude mountain regions up to 4000 MASL.Internal electronics and components are coated for resistance to corrosive, salt-intensive conditions.Sealing elements and standard enclosures with IP65 rated protection against rain and moisture.Liquid cooling system combined with filters and enhanced protection prevents dust ingress.Low temperature and reduced noise kits (optional)Robust design for maximum power in extreme ambient conditions; Multilevel coordinated control ensures fast dynamic response; Advanced control to support grid forming; Full power rating up to 1500 VDC ensures efficient project sizing(hitachienergy.com)Load leveling; Frequency regulation; Capacity firming; Peak shaving; Voltage support; Islanding; Black start; Grid inertia(hitachienergy.com)Effective operating conditions in remote high-altitude; Coating on internal components and electronics to resist corrosive saline conditions; Sealing elements and standard IP65 enclosure; Protection against rain and humidity(hitachienergy.com)
More PCS from Hitachi Energy India
- PCS WD3Power Conversion System, power conversion station for utility-scale BESS (up to 1500 Vdc)
Hitachi Energy India PCS WD4, in short
The Hitachi Energy India PCS WD4 is a PCS rated 4839 kW, with max efficiency 98.82%, cooling Liquid and MV transformer built in: no. Its max efficiency (98.82%) is above the median of the 45 PCS listed (98.7%). Hitachi Energy India has 1 other PCS on this site.
Questions about the Hitachi Energy India PCS WD4
- What are the main specifications of the Hitachi Energy India PCS WD4?
- Rated 4839 kW; Max efficiency 98.82%; Cooling Liquid; MV transformer built in: no. As printed on Hitachi Energy India's datasheet (checked November 2026); the full list is on this page.
- Where can I find the Hitachi Energy India PCS WD4 datasheet?
- Hitachi Energy India publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
- Who makes the Hitachi Energy India PCS WD4?
- Hitachi Energy India, with its head office in Bengaluru. It has 2 PCS on this site, including this one.
Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.
Values as Hitachi Energy India prints them in the linked datasheet; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Hitachi Energy India. Product and company names are trademarks of their owners, used only to identify the product.