As printed in the spec page, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.
Capacity
Energy Energy: How much electricity it stores. A 5 kWh battery can run a 1 kW load for about 5 hours, a little less in practice. The Energy basis row says whether this is usable or nominal energy.
NA
Printed configurations Printed configurations: The sizes the maker lists for this model or series, usually made by stacking identical modules. Pick the one that covers the hours of backup you need.
NA
Energy basis Energy basis: Usable is the energy you can actually draw; nominal is the total the cells hold, so it reads higher. Compare like with like.
NA
Nominal energy Nominal energy: The total energy the cells hold when full. The battery management system (BMS) keeps part of it in reserve to protect the cells, so usable energy is roughly this figure times the depth of discharge.
NA
Depth of discharge Depth of discharge: Depth of discharge: how much of the stored energy you can use before the battery stops discharging. At 90%, a 10 kWh battery gives about 9 kWh. Lithium batteries usually allow 80–95%.
NA
Expandable to Expandable to: The largest size the system can grow to by adding modules later. Useful if you expect more load, solar or an EV; check whether new modules can be added to older ones.
NA
Power
Continuous power Continuous power: How much power it can supply steadily. It has to cover everything you want running at once during a power cut, such as lights, fans, fridge and pump; motors briefly draw more when they start.
n/a (battery only)
Inverter rating Inverter rating: For all-in-one systems, the size of the built-in inverter, given in kVA the way home inverters are sold in India. The real power it can deliver in kW is the same or lower.
NA
Battery
Chemistry Chemistry: The battery type. LFP (lithium iron phosphate) is the usual choice for homes: it handles heat well and lasts many cycles. NMC packs more energy into less space, lead-acid costs less upfront but is heavier and wears out sooner, and sodium-ion is newer.
LFP
Voltage Voltage: LV (low voltage, up to 60 V, usually 12 to 51.2 V) or HV (high voltage, often a few hundred volts). The two are not interchangeable: the battery must match the voltage your inverter accepts.
LV
Nominal voltage Nominal voltage: The battery's typical working voltage. It must match the inverter's battery input; 12, 24 and 48 V systems are common, and LFP batteries for them are rated 12.8, 25.6 and 51.2 V.
51.2 V
Overview
System System: Battery only: connects to a separate inverter, which you buy or may already have. All-in-one: battery and inverter in one product, with less wiring and one supplier to deal with.
Battery only
Performance
Round-trip efficiency RTE (round-trip efficiency): The share of energy you get back out of what you put in: 90% means 10 kWh lost per 100 kWh stored. Check what it is measured on (DC side or AC system); makers differ.
NA
Cycle life DoD (depth of discharge): How much of the battery's capacity a cycle uses. Cycle-life claims depend on it: 6000 cycles at 80% DoD is not the same as at 100%.
NA
Warranty
Warranty Warranty: Years of maker's warranty. Read the terms: lithium warranties often also limit the total energy or cycles, promise a minimum remaining capacity at the end, and depend on correct installation.
5 years
Physical
IP rating IP rating: How well the enclosure keeps out dust and water (IP code: first digit dust, second digit water). IP20 is for indoor use only; IP54 and above can go in a sheltered outdoor spot.
NA
Operating temperature Operating temperature: The ambient range it is built to run in. Check the top end against your site's summer peak (Indian summers often pass 45 °C); output may be reduced (derated) near the limit. Lithium batteries also charge slowly or not at all near freezing.
NA
Weight Weight: What the wall, floor or stand must carry, and how many people it takes to lift it into place. Wall-mounted units need a solid wall and suitable anchors.
40 kg
Dimensions Dimensions: Outside size, as printed by the maker (often W × D × H). Leave room around it for access, cabling and ventilation.
485 × 146 × 450 mm (axes not stated)
Compliance
Certifications Certifications: The standards it is tested to. IEC 62619 (IS 16805 in India) covers safety of lithium batteries for stationary use, UN 38.3 safe transport, and IS 16221 / IEC 62109 inverter safety in all-in-one units. A BIS registration number (R-…) shows the product is registered with India's standards body.
The Hykon India HiLIFE 51.2V 100Ah is a home BESS, with system Battery only and chemistry LFP. Hykon India has 3 other home BESS on this site.
Questions about the Hykon India HiLIFE 51.2V 100Ah
What are the main specifications of the Hykon India HiLIFE 51.2V 100Ah?
System Battery only; Chemistry LFP. As printed on Hykon India's spec page (checked November 2026); the full list is on this page.
Where can I find the Hykon India HiLIFE 51.2V 100Ah spec page?
Hykon India publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
Who makes the Hykon India HiLIFE 51.2V 100Ah?
Hykon India, with its head office in Thrissur. It has 4 home BESS on this site, including this one.
Spot a wrong or outdated figure?Report a correction and we'll check it against the maker's current sheet.
Values as Hykon India prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Hykon India. Product and company names are trademarks of their owners, used only to identify the product.