Messung Systems NX3030
Listed A–Z, not ranked · Reviewed November 2026
Remote I/O and PLCs by Messung Systems
Specifications
Datasheet on messungautomation.co.in(opens in a new tab)Product pageon messungautomation.co.in (opens in a new tab)
As printed in the datasheet, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.
General
- Type
- PLC
- CPU
- 32-bit high-speed processing; floating point unit
- Memory
- Program memory 8 Mbytes; symbolic variable memory 6 Mbytes; retain/persistent 112 Kbytes
I/O
- Max I/O
- 128 I/O modules
Interfaces
- Protocols
- Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT, OPC UA, MQTT, IEC 60870-5-104, DNP3
- Redundancy
- Yes
Software
- Programming languages
- ST, LD, SFC, FBD, CFC
Build
- Operating temperature
- 0–60 °C
- Supply voltage
- NA
- Mounting
- NA
Certification
- Certifications
- CE, UL, DNV
- Model code:
- NX3030
- Checked:
- November 2026, against the datasheet
More Remote I/O and PLCs from Messung Systems
Messung Systems NX3030, in short
The Messung Systems NX3030 is a remote I/O and PLCs, with type PLC, max I/O 128 I/O modules, protocols Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT, OPC UA, MQTT, IEC 60870-5-104, DNP3 and programming languages ST, LD, SFC, FBD, CFC. Messung Systems has 8 other remote I/O and PLCs on this site.
Questions about the Messung Systems NX3030
- What are the main specifications of the Messung Systems NX3030?
- Type PLC; Max I/O 128 I/O modules; Protocols Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT, OPC UA, MQTT, IEC 60870-5-104, DNP3; Programming languages ST, LD, SFC, FBD, CFC. As printed on Messung Systems' datasheet (checked November 2026); the full list is on this page.
- Where can I find the Messung Systems NX3030 datasheet?
- Messung Systems publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
- Who makes the Messung Systems NX3030?
- Messung Systems, with its head office in Pune. It has 9 remote I/O and PLCs on this site, including this one.
Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.
Values as Messung Systems prints them in the linked datasheet; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Messung Systems. Product and company names are trademarks of their owners, used only to identify the product.