Rating
- Rated energy
- 20257 kWh
- Rated power
- 10000 kW
- Charge/discharge rate
- NA
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- NA
Battery
- Cell capacity
- NA
- Chemistry
- LFP
- DC voltage range
- NA
- Cycle life
- 8000 cycles
Electrical
- AC voltage
- 33000 V
- AC frequency
- 50
- Round-trip efficiency
- 88 %
- Efficiency measured
- AC system
Physical
- Size (mm)
- NA
- Weight
- NA
- Enclosure rating
- NA
Environment
- Operating temperature
- NA
- Max altitude
- NA
Safety
- Fire suppression
- NA
- Certifications
- NA
- Size:
- 10000 kW
- , 20257 kWh
- , 10000 kW / 20257 kWh
- Model code:
- CTX-B20
- Checked:
- November 2026, against the spec page
Note
An energy block of four CTX-5000 containers.
Full datasheet
Every row the maker prints, copied as written, read 2026-11-15.
Overview
- Model
- CTX-B20 CTX Block 10 MW · 10 MW / 20.26 MWh · ~2 h
- Product line
- Utility-scale · 1.75 MW – 10 MW4 × CTX-5000 · 33 kV energy block · Utility & DISCOM storage · IPP solar/wind firming · ancillary services
- Description
- 10 MW / 20.26 MWh energy block: four CTX-5000 containers, 80 racks and 20,160 LFP cells behind four 2.75 MVA transformers and a 33 kV RMU. Sub-100 ms full reversal and IEC 61850 control for wholesale arbitrage, frequency response and black start.
Battery
- Cells
- 20,160
- Battery clusters
- 80 (252S1P)
- Units (containers)
- 4 × CTX-5000
- Rated energy
- 20.26 MWh20,257 kWh
- Usable energy
- 18.23 MWh
- Cycle life
- 8,000 cycles
Power and grid
- Rated AC power
- 10 MW10,000 kW
- PCS
- 80 × 125 kW modules · 8 × 1.25 MW cabinets
- Rated AC current
- 175 A (192 A at 11 MVA)
- AC voltage
- 33 kV33 kV · 3-phase · 50 Hz
- Transformer
- 4 × 2.75 MVA · 0.4 / 33 kV · Dyn11
- MV switchgear
- 33 kV RMU · 630 / 1250 A · 25 kA 3 s
- Round-trip efficiency
- 88% at 33 kV
- Reactive power
- ± 2 MVAr at 10 MW
- Ramp up/down time
- < 200 ms
- Response time
- < 100 ms< 100 ms full reversal
- Auxiliary consumption
- 1.5–2.5% of rated
Physical
- Site footprint
- ~1,125 m² (45 × 25 m)
Communication
- Communication
- IEC 61850 · Modbus TCP
- BMS / EMS
- In-house TOBOR BMS + EMSTOBOR PDMS supervisory switching
Features
- Application
- Arbitrage · frequency response · black start / islandingCharge in low-price blocks and discharge into evening peaks. 8,000-cycle LFP and liquid cooling built for daily cycling.Sub-100 ms full reversal and < 200 ms 0–100% ramp at block level, with IEC 61850 plant control.Co-locate with solar or wind to shape output, firm capacity and reduce curtailment at the point of interconnection.
- Feature
- Block-level black-start capability with DG-backed auxiliaries, subject to the approved single-line design.
Tobor CTX-B20, in short
The Tobor CTX-B20 is a container BESS rated 10000 kW, with PCS included. Tobor has 2 other container BESS on this site.
Questions about the Tobor CTX-B20
- What are the main specifications of the Tobor CTX-B20?
- Rated 10000 kW; PCS included. As printed on Tobor's spec page (checked November 2026); the full list is on this page.
- Where can I find the Tobor CTX-B20 spec page?
- Tobor publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
- Who makes the Tobor CTX-B20?
- Tobor, with its head office in Gurugram. It has 3 container BESS on this site, including this one.
Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.
Values as Tobor prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Tobor. Product and company names are trademarks of their owners, used only to identify the product.