Plant-level power control for exporting solar plants. Curtailment is applied as a controlled ceiling on active power rather than as a protection trip, so the plant stays inside its sanctioned export without dropping off. Instructions are executed and deviations recorded in the operator's required format and timing, and monthly compliance and lender reporting is generated automatically.
Ingro EMS-PPC is a power plant controller for exporting solar plants. It holds the plant to its export limit and to operator setpoints, logs generation per inverter and per block, and produces the scheduling and compliance reports required at the connection point.
Curtailment is applied as a controlled ceiling on active power rather than as a protection trip, so the plant stays inside its sanctioned export without dropping off. Instructions are executed and deviations recorded in the operator's required format and timing, and monthly compliance and lender reporting is generated automatically.
Plant-level control · storage optional
The assets on the site, and the controller that decides between them.
The array
rows of it — the whole plant
Storage
optional
Ingro EMS
plant controller
The connection
metered and scheduled
Add storage and the same plant can firm its own output. That is a different configuration on the same controller.
Export limit and operator setpoints maintained through curtailment control, without protection trips.
Generation logged per inverter and per block, so shortfalls are located, not estimated.
Instructions executed and deviations recorded in the operator's required format.
Monthly compliance and lender reporting, generated automatically.
It holds the plant to the limits and setpoints agreed at the connection point. The controller issues an active-power ceiling to the inverters so export stays within the sanctioned value, executes the operator's instructions and records deviations in the required format and timing, and logs generation per inverter and per block for performance analysis.
As a controlled ceiling rather than a disconnection. The curtailment ceiling is an active-power limit issued to the array, so output is held down to the permitted value and the plant continues to run — instead of protection acting and the plant coming off entirely.
Yes. Adding storage lets the same plant firm its own output, and that is a configuration of the same controller rather than a different product. Standalone tendered storage at a substation is the EMS-GS configuration.
Every configuration is delivered the same way: the controller installed and commissioned, the app, a monthly report pack for finance, lenders and auditors, and training for the operating team — all included in the delivered price.
Wired, configured and commissioned against your plant, and installed in the plant room. It is the component that operates the site.
A single-line representation of the actual plant with live power on every feeder, the state of each source, the alarm register, and the endurance available at the load currently being carried.
Read-only, for management rather than operations: whether the site is sound, what it has saved, what has occurred and what is scheduled.
The reporting suite, generated and distributed automatically, and instruction for the personnel who will operate the plant.
Site control continues with no internet connection — the controller operates the plant from the plant room.
Integrates any make of inverter, battery, converter or generator. A model not previously encountered is added as configuration.
Adding an asset is a configuration change, not new hardware.
We return a scope of supply, an equipment schedule and an indicative programme, written against the outcomes you set.
Generation, storage, standby generation and the connection, as they stand today.
Anything ordered or contractually committed; anything still open, we can specify.
The energy bill, the fuel, continuity of production, or all three, in order of priority.
Remaining, being withdrawn, or never present. This determines how much of the night storage is required to own, and how the plant is sized.