Listed A–Z, not ranked · Reviewed November 2026
BESS containers products
- Rated energy
- 5000 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 2000 kWh
- Rated power
- 1000 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 5015 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 1000 kWh
- Rated power
- 500 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 5016 kWh
- Rated power
- 1200–2350 kW
- Duration
- NA
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 1045 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 2073 kWh
- Rated power
- 1200 kW
- Duration
- 1.7 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 100 Ah
- Rated energy
- 3340 kWh
- Rated power
- 1600 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5015 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 211–2280 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 5016 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 6250 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 587 Ah
- Rated energy
- 2500–5000 kWh
- Rated power
- 1250–2500 kW
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
Vanadium redox flow battery in 40-ft High Cube containers, 250 kW / 1.25 MWh per pair of containers
- Rated energy
- 1250–5000 kWh
- Rated power
- 250–1000 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
Vanadium redox flow battery, footprint printed as a 20-ft ISO shipping container, 160 to 640 kWh
- Rated energy
- 160–640 kWh
- Rated power
- 32–128 kW
- Duration
- NA
- PCS included
- NA
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 300–5015 kWh
- Rated power
- 150–5500 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 5000–10000 kWh
- Rated power
- 1250–5000 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5000 kWh
- Rated power
- 1250–2500 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 7763.6 kWh
- Rated power
- n/a (no PCS)
- Duration
- NA
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 648 Ah
- Rated energy
- 611.33 kWh
- Rated power
- 300 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
Air-cooled 20-ft container with battery, PCS, EMS and ATS; GS versions add PV MPPT input
- Rated energy
- 2057 kWh
- Rated power
- 500–1000 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- 314 Ah
Liquid-cooled 20-ft DC battery container, sold with WS-PCS1125-2-A PCS and WS-TS1000-2-A switching cabinet
- Rated energy
- 4340 kWh
- Rated power
- n/a (no PCS)
- Duration
- NA
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
Liquid-cooled 20-ft DC battery container, sold with WS-MV5000 / WS-MV2500 PCS and step-up units
- Rated energy
- 5016 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5015 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 3134 kWh
- Rated power
- 1500 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5016 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 1044 kWh
- Rated power
- 500 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5000 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5015 kWh
- Rated power
- n/a (no PCS)
- Duration
- NA
- PCS included
- No
- Cooling
- NA
- Cell capacity
- 628 Ah
- Rated energy
- NA
- Rated power
- NA
- Duration
- NA
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
Liquid-cooled battery enclosures in ISO-size containers, 2000 Series (40-ft class) and 5000 Series (20-ft)
- Rated energy
- 2436–5644 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
Modular utility-scale system of battery pods on a smart skid, 7.5 MWh and 10 MWh configurations
- Rated energy
- 7308–10000 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 5000 kWh
- Rated power
- 2500 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 5015 kWh
- Rated power
- n/a (no PCS)
- Duration
- NA
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5000 kWh
- Rated power
- 2500 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 4180 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5016 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 6250 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 587 Ah
- Rated energy
- 6250 kWh
- Rated power
- n/a (no PCS)
- Duration
- 4 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 1175 Ah
- Rated energy
- 6900 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- NA
- Rated power
- NA
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 10030 kWh
- Rated power
- 5000 kW
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 3450 kWh
- Rated power
- n/a (no PCS)
- Duration
- NA
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 2032–2064 kWh
- Rated power
- 1016–2064 kW
- Duration
- NA
- PCS included
- No
- Cooling
- Air
- Cell capacity
- 280 Ah
- Rated energy
- 4472 kWh
- Rated power
- 2236 kW
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 280 Ah
- Rated energy
- 5015 kWh
- Rated power
- 2507.5 kW
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5015.96 kWh
- Rated power
- 2500 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5015.96 kWh
- Rated power
- 2500 kW
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- NA
- Rated power
- 8000 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 6400–12800 kWh
- Rated power
- 1600–3200 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 600 Ah
| Details | PCS included | Add to plan, favourite | |||||||
|---|---|---|---|---|---|---|---|---|---|
| AmpereHour Energy | AH-5MWh DC BlockLiquid-cooled 5 MWh DC battery block (AH-Stack DC Block) | 5000 kWh | NA | NA | NA | Liquid | NA | ||
| Ashbee Energy Systems | Magnum 1 MW / 2 MWhSolar and GEN BESS, Container >1MWh | 2000 kWh | 1000 kW | 2 h | Yes | Liquid | NA | ||
| Ashbee Energy Systems | Magnum 5 MWhLiquid Cooling Energy Storage Outdoor Cabinet | 5015 kWh | NA | 2 h | NA | Liquid | 314 Ah | ||
| Ashbee Energy Systems | Magnum 500 kW / 1 MWhSolar & GEN BESS, Container <1MWh | 1000 kWh | 500 kW | 2 h | Yes | NA | NA | ||
| Canadian Solar | SolBank 3.020-ft liquid-cooled DC battery container, 5 MWh (e-STORAGE) | 5016 kWh | 1200–2350 kW | NA | No | Liquid | 314 Ah | ||
| CLN Energy | 1 MWh BESS Solution | 1045 kWh | NA | 2 h | NA | Liquid | 314 Ah | ||
| CLN Energy | 2 MWh BESS Solution | 2073 kWh | 1200 kW | 1.7 h | Yes | Liquid | 100 Ah | ||
| CLN Energy | 3 MWh BESS Solution | 3340 kWh | 1600 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| CLN Energy | 5 MWh BESS SolutionContainerised 5.015 MWh BESS | 5015 kWh | NA | 2 h | NA | Liquid | 314 Ah | ||
| Cummins India | Cummins BESS10-ft and 20-ft high cube containers, 211–2280 kWh | 211–2280 kWh | NA | 2 h | Yes | Liquid | NA | ||
| Cygni Energy | Cygni Max5MWh DC Block | 5016 kWh | n/a (no PCS) | 2 h | No | Liquid | 314 Ah | ||
| Cygni Energy | Cygni Ultra Max6.25MWh DC Block | 6250 kWh | n/a (no PCS) | 2 h | No | Liquid | 587 Ah | ||
| Cygni Energy | Flex Stack | 2500–5000 kWh | 1250–2500 kW | NA | NA | Liquid | NA | ||
| Delectrik Systems | RFB MW SeriesVanadium redox flow battery in 40-ft High Cube containers, 250 kW / 1.25 MWh per pair of containers | 1250–5000 kWh | 250–1000 kW | NA | Yes | NA | NA | ||
| Delectrik Systems | RFB160X SeriesVanadium redox flow battery, footprint printed as a 20-ft ISO shipping container, 160 to 640 kWh | 160–640 kWh | 32–128 kW | NA | NA | NA | NA | ||
| Delta Electronics India | Battery Energy Storage System | 300–5015 kWh | 150–5500 kW | NA | Yes | NA | NA | ||
| Delta Electronics India | DELTerra M2 | 5000–10000 kWh | 1250–5000 kW | NA | Yes | Liquid | 314 Ah | ||
| Delta Electronics India | DELTerra U | 5000 kWh | 1250–2500 kW | NA | Yes | Liquid | NA | ||
| DeltaX | X-HyperionUtility battery block in a 20-ft container, 648 Ah cells, liquid cooling | 7763.6 kWh | n/a (no PCS) | NA | No | Liquid | 648 Ah | ||
| DeltaX | X-OrionC&I all-in-one AC power block with PCS, 611 kWh / 300 kW | 611.33 kWh | 300 kW | 2 h | Yes | NA | NA | ||
| Deye | WS-G(S)2000-2/4H3Air-cooled 20-ft container with battery, PCS, EMS and ATS; GS versions add PV MPPT input | 2057 kWh | 500–1000 kW | NA | Yes | Air | 314 Ah | ||
| Deye | WS-L4300-BC-3Liquid-cooled 20-ft DC battery container, sold with WS-PCS1125-2-A PCS and WS-TS1000-2-A switching cabinet | 4340 kWh | n/a (no PCS) | NA | No | Liquid | 314 Ah | ||
| Deye | WS-L5000-BC-2Liquid-cooled 20-ft DC battery container, sold with WS-MV5000 / WS-MV2500 PCS and step-up units | 5016 kWh | n/a (no PCS) | 2 h | No | Liquid | 314 Ah | ||
| Ecosolex | TB-BESS-5MWhLiquid-cooled battery container, 20-ft | 5015 kWh | n/a (no PCS) | 2 h | No | Liquid | 314 Ah | ||
| Ecosolex | Valtrix String 3.0All-in-one liquid-cooled storage system with PCS, 20-ft footprint | 3134 kWh | 1500 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| Electres | Electres Grid5 MWh Liquid-Cooled Containerized BESS | 5016 kWh | n/a (no PCS) | 2 h | No | Liquid | 314 Ah | ||
| Enerveda Vault | CORE 1044 | 1044 kWh | 500 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| Enerveda Vault | TITAN 5000 | 5000 kWh | n/a (no PCS) | 2 h | No | Liquid | 314 Ah | ||
| EVE Energy | Mr. Giant 5MWh20-ft DC battery container with 628 Ah MB56 cells | 5015 kWh | n/a (no PCS) | NA | No | NA | 628 Ah | ||
| Fluence | GridstackGrid-scale system built from factory-built Fluence Cube battery enclosures | NA | NA | NA | Yes | NA | NA | ||
| Fluence | Gridstack ProLiquid-cooled battery enclosures in ISO-size containers, 2000 Series (40-ft class) and 5000 Series (20-ft) | 2436–5644 kWh | NA | NA | NA | Liquid | NA | ||
| Fluence | SmartstackModular utility-scale system of battery pods on a smart skid, 7.5 MWh and 10 MWh configurations | 7308–10000 kWh | NA | NA | Yes | Liquid | NA | ||
| GoodEnough Energy | StorEDGE 5.0 | 5000 kWh | 2500 kW | 2 h | Yes | NA | NA | ||
| GP Eco Solutions | INV BESS 5MWhUtility-scale battery block in a 20-ft high-cube container | 5015 kWh | n/a (no PCS) | NA | No | Liquid | 314 Ah | ||
| Hanum Energy | Container 5000 | 5000 kWh | 2500 kW | 2 h | Yes | Liquid | NA | ||
| Hithium | ∞Block 4.180MWhLiquid-cooled 20-ft battery container | 4180 kWh | NA | 2 h | NA | Liquid | 314 Ah | ||
| Hithium | ∞Block 5.016MWhLiquid-cooled 20-ft DC battery container | 5016 kWh | n/a (no PCS) | 2 h | No | Liquid | 314 Ah | ||
| Hithium | ∞Power 6.25MWh 2hLiquid-cooled 20-ft DC battery container | 6250 kWh | n/a (no PCS) | 2 h | No | Liquid | 587 Ah | ||
| Hithium | ∞Power 6.25MWh 4hLiquid-cooled 20-ft DC battery container | 6250 kWh | n/a (no PCS) | 4 h | No | Liquid | 1175 Ah | ||
| Hithium | ∞Power 6.9MWh 8hLiquid-cooled 8-hour battery container | 6900 kWh | NA | NA | NA | Liquid | NA | ||
| Hithium | ∞Power FlexssoModular 10-ft liquid-cooled battery container | NA | NA | NA | NA | Liquid | NA | ||
| Hoymiles | HoyPrime 10MWhLiquid-cooled LFP battery container (listed as 5MW | 10MWh) | 10030 kWh | 5000 kW | 2 h | No | Liquid | NA | ||
| Hoymiles | HoyPrime 3.45MWhLiquid-cooled LFP battery container | 3450 kWh | n/a (no PCS) | NA | No | Liquid | NA | ||
| Huawei Digital Power | LUNA2000-2.0MWH SeriesSmart String ESS, air-cooled battery container | 2032–2064 kWh | 1016–2064 kW | NA | No | Air | 280 Ah | ||
| Huawei Digital Power | LUNA2000-4472-2SSmart String ESS, battery container | 4472 kWh | 2236 kW | 2 h | No | Liquid | 280 Ah | ||
| Huawei Digital Power | LUNA2000-5015-2SSmart String Grid Forming ESS, battery container | 5015 kWh | 2507.5 kW | 2 h | No | Liquid | 314 Ah | ||
| HyperStrong | HyperBlock III5 MWh AC version, 20-ft liquid-cooled container | 5015.96 kWh | 2500 kW | 2 h | Yes | Liquid | 314 Ah | ||
| HyperStrong | HyperBlock III DC5 MWh battery-only 20-ft liquid-cooled container | 5015.96 kWh | 2500 kW | 2 h | No | Liquid | 314 Ah | ||
| HyperStrong | HyperBlock IV ACNew-generation liquid-cooled energy storage system AC (新一代液冷储能系统 AC) | NA | 8000 kW | NA | Yes | Liquid | NA | ||
| HyperStrong | HyperBlock M ACModular liquid-cooled AC block, built from 10-ft high-cube units | 6400–12800 kWh | 1600–3200 kW | NA | Yes | Liquid | 600 Ah |
125 products
Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.
Browse BESS containers by size
Power × energy grid →Each size has its own page with the products side by side.
Is your company on this list? Add it, update your details or raise a concern →
New to BESS containers? What they are, and what each spec means
A container BESS packs battery racks, a battery management system, cooling and fire protection into a shipping-container-sized enclosure, usually holding several megawatt-hours. These are the systems behind grid-scale storage tenders, solar-plus-storage plants and large industrial sites. The companies below build or integrate them for the Indian market.
What each spec means
- Rated energy(kWh)
- How much electricity it stores when full. A 1000 kWh system can supply 250 kW for about 4 hours. Size it against the hours of backup you need, or the load you want to shift.
- Rated power(kW)
- The most it can charge or discharge at once. It has to cover the load you want to run from the battery. Battery-only blocks, sold without their inverter (PCS), often print no kW figure.
- Duration(h)
- How many hours the system can deliver its rated power from full. Worked out by us, not printed by the maker: rated energy ÷ rated power, or 1 ÷ the printed charge/discharge rate (0.5P = 2 h). Shown only when the sheet prints one energy and one power figure, or a rate.
- PCS included
- The PCS (power conversion system) is the battery's inverter: it turns the battery's DC into the AC your site uses. "No" means a battery-only block, and the PCS is bought and wired separately.
- Cooling
- How the cells are kept at the right temperature. Liquid cooling keeps cells more even and suits hot sites and heavy daily use; air cooling is simpler and common in smaller systems.
- Cell capacity(Ah)
- The size of each battery cell. 280 and 314 Ah are today's mainstream; cells of 500 Ah and more are newer. It tells you the cell generation, not how good the system is.
- Charge/discharge rate(P)
- How fast a battery charges or discharges compared with its size. 0.5P means full power is half the energy rating: 5000 kWh at 0.5P gives 2500 kW, for about 2 hours. 1P empties in about 1 hour.
- Chemistry
- The battery type. LFP (lithium iron phosphate) is the standard for stationary storage: it handles heat better and lasts longer than NMC.
- DC voltage range(V)
- The battery's voltage from empty to full. The PCS must work across this window, which matters when the battery and the PCS come from different makers.
- AC voltage(V)
- The voltage at the system's AC output. Large blocks often output 690 V or come with a transformer to 11 or 33 kV; if it differs from your site's supply (415 V in most factories), a transformer goes in between.
- AC frequency(Hz)
- India's grid runs at 50 Hz. A model listed only at 60 Hz is a variant for other markets.
- Round-trip efficiency(%)
- The share of energy you get back out of what you put in: 90% means 10 kWh lost per 100 kWh stored. Check what it is measured on (DC side or AC system); makers differ.
- Efficiency measured
- Where the efficiency was measured. A DC-side figure leaves out the inverter's losses, so it looks higher than an AC figure; an AC figure that includes auxiliary loads (cooling, controls) is closest to what you actually get back. Compare like with like.
- Cycle life(cycles)
- How much of the battery's capacity a cycle uses. Cycle-life claims depend on it: 6000 cycles at 80% DoD is not the same as at 100%.
- Size (mm)
- Outside size, W × D × H or as printed. A 20-ft container is about 6058 × 2438 × 2896 mm, a 10-ft one about 2991 × 2438 × 2896 mm. Leave room for the doors to open, for cabling and for a crane or truck to place it.
- Weight(kg)
- What the foundation and the crane must take. A full 20-ft, 5 MWh container weighs roughly 40 tonnes or more, so both are part of the job.
- Enclosure rating
- How well the enclosure keeps out dust and water (IP code: first digit dust, second digit water). IP54 or IP55 is usual for outdoor units; some sheets print a US NEMA type instead.
- Operating temperature(°C)
- The outdoor (ambient) temperatures it is built to run in. Check the top end against your site's summer peak (Indian summers often pass 45 °C); output may be reduced (derated) near the limit.
- Max altitude(m)
- Thin air cools less well. Above this height the output is reduced, or the warranty may not apply. Most Indian sites are well below 2000 m; it matters mainly in the hill states.
- Fire suppression
- What the system does if a cell overheats: gas, smoke and heat detectors raise the alarm, gas or aerosol puts out a fire, and vents or panels let explosive gas out safely. Some add a water spray or sprinkler line.
- Certifications
- The safety and grid standards it is tested to. IEC 62619 covers battery safety, IEC 62933 and UL 9540 the whole storage system, UL 9540A how a fire spreads between cells and racks, and UN 38.3 safe transport. In India, also ask which BIS (IS) certifications the cells and the PCS carry.
NA in the table means the maker doesn't publish that figure. It is worth asking them for it.
What to compare before you choose
- Cell chemistry and cell supplier (most containers today use LFP), and whether the cells are made in India.
- Usable energy per container, round-trip efficiency at the point of connection, and the warranted cycles and end-of-life capacity.
- Cooling method (air or liquid) and how it copes with Indian summer ambient temperatures.
- Fire safety design and certifications such as UL 9540A test data, and what the container does on an off-gas alarm.
- Who supplies the PCS and the plant controller, and whether the BMS exposes its data over an open protocol.
- Service presence in India: spares, response time and who commissions the system.
125 products from 50 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.