15 kVA DG sets (diesel and gas generator sets) in India

12 products from 10 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026

15 kVA DG sets suit small commercial buildings, schools, clinics and small workshops. Most are three-phase, many with a single-phase option, in a canopy that meets the CPCB noise limits. Check whether the set prints a CPCB IV+ emission compliance if that matters for the site.

15 kVA compared

A–Z by company, not ranked · NA: not published by the maker

FieldAshok LeylandLeypowerCPCB4+ Diesel Genset, LP15 to LP250Cooper CorporationCooper Diesel Genset 15 kVACummins IndiaX2.5 Series7.5 - 20 kVA, 6 - 16 kWe PrimeJakson GroupJSP-IVSilent diesel generating sets, radiator cooled, 7.5 to 750 kVAJoyshree Powerol15 KVA DG SetKirloskar Oil EnginesKG4-15AS NG115 kVA Natural Gas GeneratorKirloskar Oil EnginesKG4-15WS115 kVA Diesel GeneratorMahindra PowerolGas gensets 10.5 to 125 kVAGas gensets, 10.5, 15, 20, 25, 100 and 125 kVAMahindra PowerolM10DR to M650DRAcoustic DG sets, 10 to 650 kVAOjus Power and TechnologiesOL seriesDiesel generators, 15 to 250 kVAPinnacle Generators15 kVAGenset model PG-15Sudhir PowerCS D5P seriesCummins-powered silent diesel gensets (2023 brochure)
Output
Rating 15–250 kVA15 kVA7.5–20 kVA7.5–750 kVA15 kVA15 kVA15 kVA10.5–125 kVA10–650 kVA15–250 kVA15 kVA7.5–2250 kVA
Power output 12–200 kWe12 kWe6–16 kWe6–600 kWeNANA12 kWe8.4–100 kWe8–520 kWe12–200 kWeNANA
Printed ratings 15, 25, 30, 35, 40, 45, 60, 75, 82.5, 100, 125, 160, 180, 250 kVA15 kVA7.5, 10, 15, 20 kVA7.5, 10, 15, 18.5, 20, 25, 27.5, 30, 35, 40, 41, 50, 58.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 320, 380, 400, 500, 650, 750 kVANA15 kVA15 kVA10.5, 15, 20, 25, 100, 125 kVA10, 15, 20, 25, 30, 35, 40, 45, 50, 58.5, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 400, 500, 525, 650 kVA15, 20, 25, 30, 35, 40, 45, 60, 82.5, 100, 125, 160, 180, 250 kVA15 kVA7.5, 10, 15, 20, 25, 30, 35, 40, 50, 62.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 275, 300, 320, 380, 400, 500, 600, 625, 650, 750, 810, 910, 1010, 1250, 1500, 1800, 2000, 2250 kVA
Rating basis NANAPrimeNANANAPrimePrimeNANAPrimePrime
Output voltage NANA415NA220-415230 V230 (1ɸ) & 415 (3ɸ)230 / 415 (10.5 to 25 kVA), 415V (100 and 125 kVA)230/415 (10 to 40 kVA), 415 (3 phase) aboveNA230 V AC / 415 V ACNA
Frequency NANA50 HzNANA50 Hz50 Hz50 Hz50 HzNA50 HzNA
Power factor NANA0.8 (lagging)NANANA0.80.8 lagging0.8 laggingNA0.8 lagNA
Phase NA1-phase, 3-phase3-phase1-phase, 3-phase3-phaseNA1-phase, 3-phase1-phase, 3-phase1-phase, 3-phaseNA1-phase, 3-phaseNA
Build
Fuel DieselDieselDieselDieselNAGasDieselGasNADieselNANA
Engine H2G4DM15, P15G4DE25 and othersNACummins X2.5-G5 and X2.5-G6X2.5-G5 to QSK19-G30 (and others)NAHA294 NG13R550TC 4G1Mahindra mGreen3235NGC4+ and othersMahindra M2155G1 and others; Perkins 2806FA-E18TAG1 and 2806FA-E18TAG2 for 400 to 650 kVAH2G4DM15, ALG184, P15G4DE25 and othersEicher Engines 220A0-EG015X1.3TAA-G1, X1.3TAA-G7
Alternator NANASTAMFORD S0L1 and S0L2 frames (S0L1-D, S0L1-H, S0L1-P, S0L2-M)NANANANACG/LS/STAMFORD (10.5 and 15 kVA), CG/LS (others)CG/LS/EquivalentNACG / Leroy Somer / Meccalte / StamfordNA
Enclosure AcousticAcousticAcousticAcousticNAAcousticAcousticNAAcousticNAAcousticAcoustic
Dimensions (L × W × H) 4700 × 1600 × 2020 mm (axes not stated)1777 × 830 × 1050 mm (axes not stated)2190 × 875 × 1150 mm (axes not stated)6800 × 2050 × 2860 mm (axes not stated)NA1740 × 1050 × 1410 mm (axes not stated)1850 × 760 × 1050 mm (axes not stated)3750 × 1300 × 1700 mm (axes not stated)5800 × 2200 × 2300 mm (axes not stated)4700 × 1600 × 2020 mm (axes not stated)1800 × 900 × 1275 mm (axes not stated)10450 × 3500 × 3800 mm (axes not stated)
Fuel tank capacity 55 to 340NA85 to 9085 to 980NANANANA55 to 80050 to 34080NA
Weight about 676–4500 kg670 kgabout 772–820 kgabout 772–10156 kgNA850 kg610 kgabout 720–2250 kg690–3920 kgabout 676–4500 kg870 kgNA
Certification
CPCB IV+ YesYesYesYesNANAYesNANAYesNANA
Certifications and standards BS 5514, ISO 3046, ISO 8528NAIS/IEC 60034-1, ISO 1460, ISO 8528, ISO 3046, ISO 9001, ISO 13018NAARAIISO 8528ISO 8528ISO 8528 part 5 (governing class, 20 to 125 kVA)IS/IEC60034-1 (alternator)BS 5514, ISO 3046, ISO 8528ISO 3046-1, ISO 8528NA
Performance
Governing class A0 (A1 on LP15)NAISO 8528-5 G2G2/G3NANAG2G2G2/G3A1 (OL 15, OL 20); A0 (OL 25 to OL 250)Mechanical G2NA
Fuel consumption NANANANANANANA20 to 25 kg/hr at 75% and 100% load for 125 kVA (printed in kg/hr, not L/h)NANANANA
Noise level NANA75 dBA at 1 m, 75% load, free fieldNANA< 75 dB(A)<75 dBANANANANA75 dBA at 1 m
Controls
Controller GC 902 and GC 1206NACummins PowerStart PS0600NANANANANAGC 1115 (10 to 200 kVA), GC 1116 (250 and 320 kVA), DSE7320 (400 to 650 kVA)GC 1207 (OL 15), DEIF SGC120 (OL 20), GC 1206 (OL 25 to OL 250)TMTL Genset Control UnitPS0600/1/2 (15-1010 kVA); PCC 3201 (1250-3750 kVA)
Support
Warranty NANA5 Yrs engine critical parts warranty5C Warranty (5 years/ 5000 hours)1 YearNANANAStandard warranty of 2 Years/5000 Hours, 5 Years 5C warranty5 Years or 8000 hrs, T&C apply (OL 20: 2 years or 5000 hrs whichever occurs earlier)Warranty period covers 2 Years or 5000 Hours run* (whichever is earlier). Warranty on 5C covers 5 Years or 5000 Hours run* (whichever is earlier). * Terms and conditions applyNA
Source
NoteSeries of 13 diesel sets from 15 kVA to 250 kVA; each set has its own specification page on the maker's site.Specifications as printed on the maker's product page; no PDF datasheet linked.Sheet prints the ratings, engine models, tank size and weight for 13 models.
Model codeLP15, LP25, LP30, LP35/40, LP45, LP60, LP75/82.5, LP100, LP125, LP160, LP180, LP250NACI 7.5D5P, CI 10D5P, CI 15D5P, CI 20D5PJSP-IV 7.5 to JSP-IV 750NANANANAM10DR to M650DROL 15, OL 20, OL 25, OL 30, OL 35/40, OL 45, OL 60, OL 82.5, OL 100, OL 125, OL 160, OL 180, OL 250NACS 7.5 D5P to CS 2250 D5P
DatasheetSpec page of Ashok Leyland Leypower (opens the maker's site)Spec page of Cooper Corporation Cooper Diesel Genset 15 kVA (opens the maker's site)Datasheet (PDF) of Cummins India X2.5 Series (opens the maker's site)Datasheet (PDF) of Jakson Group JSP-IV (opens the maker's site)Spec page of Joyshree Powerol 15 KVA DG Set (opens the maker's site)Spec page of Kirloskar Oil Engines KG4-15AS NG1 (opens the maker's site)Spec page of Kirloskar Oil Engines KG4-15WS1 (opens the maker's site)Spec page of Mahindra Powerol Gas gensets 10.5 to 125 kVA (opens the maker's site)Datasheet (PDF) of Mahindra Powerol M10DR to M650DR (opens the maker's site)Datasheet (PDF) of Ojus Power and Technologies OL series (opens the maker's site)Spec page of Pinnacle Generators 15 kVA (opens the maker's site)Datasheet (PDF) of Sudhir Power CS D5P series (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026
DetailsDetails of Ashok Leyland LeypowerDetails of Cooper Corporation Cooper Diesel Genset 15 kVADetails of Cummins India X2.5 SeriesDetails of Jakson Group JSP-IVDetails of Joyshree Powerol 15 KVA DG SetDetails of Kirloskar Oil Engines KG4-15AS NG1Details of Kirloskar Oil Engines KG4-15WS1Details of Mahindra Powerol Gas gensets 10.5 to 125 kVADetails of Mahindra Powerol M10DR to M650DRDetails of Ojus Power and Technologies OL seriesDetails of Pinnacle Generators 15 kVADetails of Sudhir Power CS D5P series

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 12 products above, as printed.

  • Rating: 7.5 to 2250 kVA as printed (ranges included)
  • Power output: 6 to 600 kWe as printed (ranges included); 4 not published
  • Rating basis: Prime; 5 of 12 publish it
  • Fuel: 6 Diesel, 2 Gas; 4 not published
  • CPCB IV+: 6 of 12; 6 not published
  • Output voltage: 7 of 12 publish it; values in the table
  • Frequency: 50 Hz; 6 of 12 publish it
  • Power factor: 0.8 lagging on 2, 0.8 on 1, 0.8 (lagging) on 1, 0.8 lag on 1; 7 not published
  • Governing class: 8 of 12 publish it; values in the table
  • Phase: 8 of 12 publish a list; 3-phase on 8, 1-phase on 6
  • Engine: 10 of 12 publish it; values in the table
  • Alternator: 4 of 12 publish it; values in the table
  • Enclosure: Acoustic; 9 of 12 publish it
  • Fuel consumption: 20 to 25 kg/hr at 75% and 100% load for 125 kVA (printed in kg/hr, not L/h); 1 of 12 publishes it
  • Noise level: 4 of 12 publish it; values in the table
  • Controller: 6 of 12 publish it; values in the table
  • Dimensions (L × W × H): 11 of 12 publish it; values in the table
  • Fuel tank capacity: 50 to 340 on 1, 55 to 340 on 1, 55 to 800 on 1, 80 on 1, 85 to 90 on 1, 85 to 980 on 1; 6 not published
  • Weight: 610 to 10156 kg as printed (ranges included); 2 not published (5 printed as approximate)
  • Warranty: 6 of 12 publish it; values in the table
  • Certifications and standards: 9 of 12 publish a list; ISO 8528 on 6, ISO 3046 on 3, BS 5514 on 2

Questions about 15 kVA DG sets (diesel and gas generator sets)

Which companies make 15 kVA DG sets (diesel and gas generator sets) in India?
10 companies list 12 products at this size: Ashok Leyland (Leypower); Cooper Corporation (Cooper Diesel Genset 15 kVA); Cummins India (X2.5 Series); Jakson Group (JSP-IV); Joyshree Powerol (15 KVA DG Set); Kirloskar Oil Engines (KG4-15AS NG1, KG4-15WS1); Mahindra Powerol (Gas gensets 10.5 to 125 kVA, M10DR to M650DR); Ojus Power and Technologies (OL series); Pinnacle Generators (15 kVA); Sudhir Power (CS D5P series). They are listed A–Z by company, not ranked.
How do these 15 kVA DG sets (diesel and gas generator sets) differ?
Rating: 7.5 to 2250 kVA as printed (ranges included). Power output: 6 to 600 kWe as printed (ranges included); 4 not published. Rating basis: Prime; 5 of 12 publish it. Fuel: 6 Diesel, 2 Gas; 4 not published. Counted from the 12 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 15 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.