10 kVA DG sets (diesel and gas generator sets) in India

8 products from 8 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026

10 kVA is a common size for bungalows, small offices, ATMs and telecom sites. Sets here come single- or three-phase in acoustic canopies; compare the rating basis, the engine and the tank, which set the running hours at a typical load.

10 kVA compared

A–Z by company, not ranked · NA: not published by the maker

FieldCooper CorporationCooper Diesel Genset 10 kVACummins IndiaX2.5 Series7.5 - 20 kVA, 6 - 16 kWe PrimeJakson GroupJSP-IVSilent diesel generating sets, radiator cooled, 7.5 to 750 kVAJoyshree Powerol10 KVA DG SetKirloskar Oil EnginesKG4-10WS110 kVA Diesel GeneratorMahindra PowerolM10DR to M650DRAcoustic DG sets, 10 to 650 kVAPinnacle Generators10 kVAGenset model PG -10Sudhir PowerCS D5P seriesCummins-powered silent diesel gensets (2023 brochure)
Output
Rating 10 kVA7.5–20 kVA7.5–750 kVA10 kVA10 kVA10–650 kVA10 kVA7.5–2250 kVA
Power output 8 kWe6–16 kWe6–600 kWeNA8 kWe8–520 kWeNANA
Printed ratings 10 kVA7.5, 10, 15, 20 kVA7.5, 10, 15, 18.5, 20, 25, 27.5, 30, 35, 40, 41, 50, 58.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 320, 380, 400, 500, 650, 750 kVANA10 kVA10, 15, 20, 25, 30, 35, 40, 45, 50, 58.5, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 400, 500, 525, 650 kVA10 kVA7.5, 10, 15, 20, 25, 30, 35, 40, 50, 62.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 275, 300, 320, 380, 400, 500, 600, 625, 650, 750, 810, 910, 1010, 1250, 1500, 1800, 2000, 2250 kVA
Rating basis NAPrimeNANAPrimeNAPrimePrime
Output voltage NA415NA220-415230 (1ɸ) & 415 (3ɸ)230/415 (10 to 40 kVA), 415 (3 phase) above230 V AC / 415 V ACNA
Frequency NA50 HzNANA50 Hz50 Hz50 HzNA
Power factor NA0.8 (lagging)NANA0.80.8 lagging0.8 lagNA
Phase 1-phase, 3-phase3-phase1-phase, 3-phase1-phase, 3-phase1-phase, 3-phase1-phase, 3-phase1-phase, 3-phaseNA
Build
Fuel DieselDieselDieselNADieselNANANA
Engine NACummins X2.5-G5 and X2.5-G6X2.5-G5 to QSK19-G30 (and others)NA3R550NA 4G1Mahindra M2155G1 and others; Perkins 2806FA-E18TAG1 and 2806FA-E18TAG2 for 400 to 650 kVAEicher Engines 115A0-EG010X1.3TAA-G1, X1.3TAA-G7
Alternator NASTAMFORD S0L1 and S0L2 frames (S0L1-D, S0L1-H, S0L1-P, S0L2-M)NANANACG/LS/EquivalentCG / Leroy Somer / Meccalte / StamfordNA
Enclosure AcousticAcousticAcousticNAAcousticAcousticAcousticAcoustic
Dimensions (L × W × H) 1400 × 830 × 1102 mm (axes not stated)2190 × 875 × 1150 mm (axes not stated)6800 × 2050 × 2860 mm (axes not stated)NA1800 × 760 × 1050 mm (axes not stated)5800 × 2200 × 2300 mm (axes not stated)1800 × 900 × 1275 mm (axes not stated)10450 × 3500 × 3800 mm (axes not stated)
Fuel tank capacity NA85 to 9085 to 980NANA55 to 80080NA
Weight 500 kgabout 772–820 kgabout 772–10156 kgNA590 kg690–3920 kg830 kgNA
Certification
CPCB IV+ YesYesYesNAYesNANANA
Certifications and standards NAIS/IEC 60034-1, ISO 1460, ISO 8528, ISO 3046, ISO 9001, ISO 13018NAARAIISO 8528IS/IEC60034-1 (alternator)ISO 3046-1, ISO 8528NA
Performance
Governing class NAISO 8528-5 G2G2/G3NAG2G2/G3Mechanical G2NA
Fuel consumption NANANANANANANANA
Noise level NA75 dBA at 1 m, 75% load, free fieldNANA<75 DBANANA75 dBA at 1 m
Controls
Controller NACummins PowerStart PS0600NANANAGC 1115 (10 to 200 kVA), GC 1116 (250 and 320 kVA), DSE7320 (400 to 650 kVA)TMTL Genset Control UnitPS0600/1/2 (15-1010 kVA); PCC 3201 (1250-3750 kVA)
Support
Warranty NA5 Yrs engine critical parts warranty5C Warranty (5 years/ 5000 hours)1 YearNAStandard warranty of 2 Years/5000 Hours, 5 Years 5C warrantyWarranty period covers 2 Years or 5000 Hours run* (whichever is earlier). Warranty on 5C covers 5 Years or 5000 Hours run* (whichever is earlier). * Terms and conditions applyNA
Source
NoteSpecifications as printed on the maker's product page; no PDF datasheet linked.
Model codeNACI 7.5D5P, CI 10D5P, CI 15D5P, CI 20D5PJSP-IV 7.5 to JSP-IV 750NANAM10DR to M650DRNACS 7.5 D5P to CS 2250 D5P
DatasheetSpec page of Cooper Corporation Cooper Diesel Genset 10 kVA (opens the maker's site)Datasheet (PDF) of Cummins India X2.5 Series (opens the maker's site)Datasheet (PDF) of Jakson Group JSP-IV (opens the maker's site)Spec page of Joyshree Powerol 10 KVA DG Set (opens the maker's site)Spec page of Kirloskar Oil Engines KG4-10WS1 (opens the maker's site)Datasheet (PDF) of Mahindra Powerol M10DR to M650DR (opens the maker's site)Spec page of Pinnacle Generators 10 kVA (opens the maker's site)Datasheet (PDF) of Sudhir Power CS D5P series (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026
DetailsDetails of Cooper Corporation Cooper Diesel Genset 10 kVADetails of Cummins India X2.5 SeriesDetails of Jakson Group JSP-IVDetails of Joyshree Powerol 10 KVA DG SetDetails of Kirloskar Oil Engines KG4-10WS1Details of Mahindra Powerol M10DR to M650DRDetails of Pinnacle Generators 10 kVADetails of Sudhir Power CS D5P series

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 8 products above, as printed.

  • Rating: 7.5 to 2250 kVA as printed (ranges included)
  • Power output: 6 to 600 kWe as printed (ranges included); 3 not published
  • Rating basis: Prime; 4 of 8 publish it
  • Fuel: Diesel; 4 of 8 publish it
  • CPCB IV+: 4 of 8; 4 not published
  • Output voltage: 5 of 8 publish it; values in the table
  • Frequency: 50 Hz; 4 of 8 publish it
  • Power factor: 0.8 on 1, 0.8 (lagging) on 1, 0.8 lag on 1, 0.8 lagging on 1; 4 not published
  • Governing class: G2/G3 on 2, G2 on 1, ISO 8528-5 G2 on 1, Mechanical G2 on 1; 3 not published
  • Phase: 7 of 8 publish a list; 3-phase on 7, 1-phase on 6
  • Engine: 6 of 8 publish it; values in the table
  • Alternator: 3 of 8 publish it; values in the table
  • Enclosure: Acoustic; 7 of 8 publish it
  • Noise level: 3 of 8 publish it; values in the table
  • Controller: 4 of 8 publish it; values in the table
  • Dimensions (L × W × H): 7 of 8 publish it; values in the table
  • Fuel tank capacity: 55 to 800 on 1, 80 on 1, 85 to 90 on 1, 85 to 980 on 1; 4 not published
  • Weight: 500 to 10156 kg as printed (ranges included); 2 not published (2 printed as approximate)
  • Warranty: 5 of 8 publish it; values in the table
  • Certifications and standards: 5 of 8 publish a list; ISO 8528 on 3

Questions about 10 kVA DG sets (diesel and gas generator sets)

Which companies make 10 kVA DG sets (diesel and gas generator sets) in India?
8 companies list 8 products at this size: Cooper Corporation (Cooper Diesel Genset 10 kVA); Cummins India (X2.5 Series); Jakson Group (JSP-IV); Joyshree Powerol (10 KVA DG Set); Kirloskar Oil Engines (KG4-10WS1); Mahindra Powerol (M10DR to M650DR); Pinnacle Generators (10 kVA); Sudhir Power (CS D5P series). They are listed A–Z by company, not ranked.
How do these 10 kVA DG sets (diesel and gas generator sets) differ?
Rating: 7.5 to 2250 kVA as printed (ranges included). Power output: 6 to 600 kWe as printed (ranges included); 3 not published. Rating basis: Prime; 4 of 8 publish it. Fuel: Diesel; 4 of 8 publish it. Counted from the 8 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 10 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.