9 products from 9 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026
40 kVA sets back up offices, schools, hotels and small industrial units with motors and air conditioning. Compare the governing class and alternator, which decide how well the set handles motor starting, along with fuel use and size.
40 kVA compared
A–Z by company, not ranked · NA: not published by the maker
| Field | Ashok LeylandLeypowerCPCB4+ Diesel Genset, LP15 to LP250 | Cooper CorporationCooper Diesel Genset 40 kVA | Jakson GroupJSP-IVSilent diesel generating sets, radiator cooled, 7.5 to 750 kVA | Joyshree Powerol40 KVA DG Set | Kirloskar Oil EnginesKG4-40WS140 kVA Diesel Generator | Mahindra PowerolM10DR to M650DRAcoustic DG sets, 10 to 650 kVA | Ojus Power and TechnologiesOL seriesDiesel generators, 15 to 250 kVA | Pinnacle Generators40 kVAGenset model PG-40 | Sudhir PowerCS D5P seriesCummins-powered silent diesel gensets (2023 brochure) |
|---|---|---|---|---|---|---|---|---|---|
| Output | |||||||||
| Rating | 15–250 kVA | 40 kVA | 7.5–750 kVA | 40 kVA | 40 kVA | 10–650 kVA | 15–250 kVA | 40 kVA | 7.5–2250 kVA |
| Power output | 12–200 kWe | 32 kWe | 6–600 kWe | NA | 32 kWe | 8–520 kWe | 12–200 kWe | NA | NA |
| Printed ratings | 15, 25, 30, 35, 40, 45, 60, 75, 82.5, 100, 125, 160, 180, 250 kVA | 40 kVA | 7.5, 10, 15, 18.5, 20, 25, 27.5, 30, 35, 40, 41, 50, 58.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 320, 380, 400, 500, 650, 750 kVA | NA | 40 kVA | 10, 15, 20, 25, 30, 35, 40, 45, 50, 58.5, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 400, 500, 525, 650 kVA | 15, 20, 25, 30, 35, 40, 45, 60, 82.5, 100, 125, 160, 180, 250 kVA | 40 kVA | 7.5, 10, 15, 20, 25, 30, 35, 40, 50, 62.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 275, 300, 320, 380, 400, 500, 600, 625, 650, 750, 810, 910, 1010, 1250, 1500, 1800, 2000, 2250 kVA |
| Rating basis | NA | NA | NA | NA | Prime | NA | NA | Prime | Prime |
| Output voltage | NA | NA | NA | NA | 415 (3ɸ) | 230/415 (10 to 40 kVA), 415 (3 phase) above | NA | 230 V AC / 415 V AC | NA |
| Frequency | NA | NA | NA | NA | 50 Hz | 50 Hz | NA | 50 Hz | NA |
| Power factor | NA | NA | NA | NA | 0.8 | 0.8 lagging | NA | 0.8 lag | NA |
| Phase | NA | 3-phase | 1-phase, 3-phase | NA | 3-phase | 1-phase, 3-phase | NA | 1-phase, 3-phase | NA |
| Build | |||||||||
| Fuel | Diesel | Diesel | Diesel | NA | Diesel | NA | Diesel | NA | NA |
| Engine | H2G4DM15, P15G4DE25 and others | NA | X2.5-G5 to QSK19-G30 (and others) | NA | 3R1190ETA 4G1 | Mahindra M2155G1 and others; Perkins 2806FA-E18TAG1 and 2806FA-E18TAG2 for 400 to 650 kVA | H2G4DM15, ALG184, P15G4DE25 and others | TMTL Engines 333W0-EG040 | X1.3TAA-G1, X1.3TAA-G7 |
| Alternator | NA | NA | NA | NA | NA | CG/LS/Equivalent | NA | CG / Leroy Somer / Meccalte / Stamford | NA |
| Enclosure | Acoustic | Acoustic | Acoustic | NA | Acoustic | Acoustic | NA | Acoustic | Acoustic |
| Dimensions (L × W × H) | 4700 × 1600 × 2020 mm (axes not stated) | 1950 × 950 × 1300 mm (axes not stated) | 6800 × 2050 × 2860 mm (axes not stated) | NA | 2750 × 1050 × 1495 mm (axes not stated) | 5800 × 2200 × 2300 mm (axes not stated) | 4700 × 1600 × 2020 mm (axes not stated) | 2350 × 1000 × 1425 mm (axes not stated) | 10450 × 3500 × 3800 mm (axes not stated) |
| Fuel tank capacity | 55 to 340 | NA | 85 to 980 | NA | NA | 55 to 800 | 50 to 340 | 100 | NA |
| Weight | about 676–4500 kg | 780 kg | about 772–10156 kg | NA | 1180 kg | 690–3920 kg | about 676–4500 kg | 1115 kg | NA |
| Certification | |||||||||
| CPCB IV+ | Yes | Yes | Yes | NA | Yes | NA | Yes | NA | NA |
| Certifications and standards | BS 5514, ISO 3046, ISO 8528 | NA | NA | ARAI | ISO 8528 | IS/IEC60034-1 (alternator) | BS 5514, ISO 3046, ISO 8528 | ISO 3046-1, ISO 8528 | NA |
| Performance | |||||||||
| Governing class | A0 (A1 on LP15) | NA | G2/G3 | NA | G2 | G2/G3 | A1 (OL 15, OL 20); A0 (OL 25 to OL 250) | CRS Electronic G3 | NA |
| Fuel consumption | NA | NA | NA | NA | NA | NA | NA | NA | NA |
| Noise level | NA | NA | NA | NA | <75 dBA | NA | NA | NA | 75 dBA at 1 m |
| Controls | |||||||||
| Controller | GC 902 and GC 1206 | NA | NA | NA | NA | GC 1115 (10 to 200 kVA), GC 1116 (250 and 320 kVA), DSE7320 (400 to 650 kVA) | GC 1207 (OL 15), DEIF SGC120 (OL 20), GC 1206 (OL 25 to OL 250) | TMTL Genset Control Unit | PS0600/1/2 (15-1010 kVA); PCC 3201 (1250-3750 kVA) |
| Support | |||||||||
| Warranty | NA | NA | 5C Warranty (5 years/ 5000 hours) | 1 Year | NA | Standard warranty of 2 Years/5000 Hours, 5 Years 5C warranty | 5 Years or 8000 hrs, T&C apply (OL 20: 2 years or 5000 hrs whichever occurs earlier) | Warranty period covers 2 Years or 5000 Hours run* (whichever is earlier). Warranty on 5C covers 5 Years or 5000 Hours run* (whichever is earlier). * Terms and conditions apply | NA |
| Source | |||||||||
| Note | Series of 13 diesel sets from 15 kVA to 250 kVA; each set has its own specification page on the maker's site. | Specifications as printed on the maker's product page; no PDF datasheet linked. | Sheet prints the ratings, engine models, tank size and weight for 13 models. | ||||||
| Model code | LP15, LP25, LP30, LP35/40, LP45, LP60, LP75/82.5, LP100, LP125, LP160, LP180, LP250 | NA | JSP-IV 7.5 to JSP-IV 750 | NA | NA | M10DR to M650DR | OL 15, OL 20, OL 25, OL 30, OL 35/40, OL 45, OL 60, OL 82.5, OL 100, OL 125, OL 160, OL 180, OL 250 | NA | CS 7.5 D5P to CS 2250 D5P |
| Datasheet | Spec page of Ashok Leyland Leypower (opens the maker's site) | Spec page of Cooper Corporation Cooper Diesel Genset 40 kVA (opens the maker's site) | Datasheet (PDF) of Jakson Group JSP-IV (opens the maker's site) | Spec page of Joyshree Powerol 40 KVA DG Set (opens the maker's site) | Spec page of Kirloskar Oil Engines KG4-40WS1 (opens the maker's site) | Datasheet (PDF) of Mahindra Powerol M10DR to M650DR (opens the maker's site) | Datasheet (PDF) of Ojus Power and Technologies OL series (opens the maker's site) | Spec page of Pinnacle Generators 40 kVA (opens the maker's site) | Datasheet (PDF) of Sudhir Power CS D5P series (opens the maker's site) |
| CheckedFigures compared with the maker's sheet | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 |
| Details | Details of Ashok Leyland Leypower | Details of Cooper Corporation Cooper Diesel Genset 40 kVA | Details of Jakson Group JSP-IV | Details of Joyshree Powerol 40 KVA DG Set | Details of Kirloskar Oil Engines KG4-40WS1 | Details of Mahindra Powerol M10DR to M650DR | Details of Ojus Power and Technologies OL series | Details of Pinnacle Generators 40 kVA | Details of Sudhir Power CS D5P series |
Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.
What differs between them
Counted from the 9 products above, as printed.
- Rating: 7.5 to 2250 kVA as printed (ranges included)
- Power output: 6 to 600 kWe as printed (ranges included); 3 not published
- Rating basis: Prime; 3 of 9 publish it
- Fuel: Diesel; 5 of 9 publish it
- CPCB IV+: 5 of 9; 4 not published
- Output voltage: 3 of 9 publish it; values in the table
- Frequency: 50 Hz; 3 of 9 publish it
- Power factor: 0.8 on 1, 0.8 lag on 1, 0.8 lagging on 1; 6 not published
- Governing class: 6 of 9 publish it; values in the table
- Phase: 5 of 9 publish a list; 3-phase on 5, 1-phase on 3
- Engine: 7 of 9 publish it; values in the table
- Alternator: 2 of 9 publish it; values in the table
- Enclosure: Acoustic; 7 of 9 publish it
- Noise level: <75 dBA on 1, 75 dBA at 1 m on 1; 7 not published
- Controller: 5 of 9 publish it; values in the table
- Dimensions (L × W × H): 8 of 9 publish it; values in the table
- Fuel tank capacity: 100 on 1, 50 to 340 on 1, 55 to 340 on 1, 55 to 800 on 1, 85 to 980 on 1; 4 not published
- Weight: 676 to 10156 kg as printed (ranges included); 2 not published (3 printed as approximate)
- Warranty: 5 of 9 publish it; values in the table
- Certifications and standards: 6 of 9 publish a list; ISO 8528 on 4, BS 5514 on 2, ISO 3046 on 2
Nearby rating values
A page needs 3+ products from 3+ companies; values without one are in the full list by rating.
Questions about 40 kVA DG sets (diesel and gas generator sets)
- Which companies make 40 kVA DG sets (diesel and gas generator sets) in India?
- 9 companies list 9 products at this size: Ashok Leyland (Leypower); Cooper Corporation (Cooper Diesel Genset 40 kVA); Jakson Group (JSP-IV); Joyshree Powerol (40 KVA DG Set); Kirloskar Oil Engines (KG4-40WS1); Mahindra Powerol (M10DR to M650DR); Ojus Power and Technologies (OL series); Pinnacle Generators (40 kVA); Sudhir Power (CS D5P series). They are listed A–Z by company, not ranked.
- How do these 40 kVA DG sets (diesel and gas generator sets) differ?
- Rating: 7.5 to 2250 kVA as printed (ranges included). Power output: 6 to 600 kWe as printed (ranges included); 3 not published. Rating basis: Prime; 3 of 9 publish it. Fuel: Diesel; 5 of 9 publish it. Counted from the 9 products as each maker prints them.
- Where do these figures come from?
- From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 40 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.
Is your company on this list? Add it, update your details or raise a concern →