45 kVA DG sets (diesel and gas generator sets) in India

5 products from 5 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026

45 kVA sets sit between small commercial sets and mid-size industrial ones, suited to workshops, small hospitals and housing societies. They are three-phase canopied sets; check the printed basis and the tank size for the running hours needed.

45 kVA compared

A–Z by company, not ranked · NA: not published by the maker

FieldAshok LeylandLeypowerCPCB4+ Diesel Genset, LP15 to LP250Joyshree Powerol45 KVA DG SetMahindra PowerolM10DR to M650DRAcoustic DG sets, 10 to 650 kVAOjus Power and TechnologiesOL seriesDiesel generators, 15 to 250 kVAPinnacle Generators45 kVAGenset model PG-45
Output
Rating 15–250 kVA45 kVA10–650 kVA15–250 kVA45 kVA
Power output 12–200 kWeNA8–520 kWe12–200 kWeNA
Printed ratings 15, 25, 30, 35, 40, 45, 60, 75, 82.5, 100, 125, 160, 180, 250 kVANA10, 15, 20, 25, 30, 35, 40, 45, 50, 58.5, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 400, 500, 525, 650 kVA15, 20, 25, 30, 35, 40, 45, 60, 82.5, 100, 125, 160, 180, 250 kVA45 kVA
Rating basis NANANANAPrime
Output voltage NANA230/415 (10 to 40 kVA), 415 (3 phase) aboveNA230 V AC / 415 V AC
Frequency NANA50 HzNA50 Hz
Power factor NANA0.8 laggingNA0.8 lag
Phase NA3-phase1-phase, 3-phaseNA1-phase, 3-phase
Build
Fuel DieselNANADieselNA
Engine H2G4DM15, P15G4DE25 and othersNAMahindra M2155G1 and others; Perkins 2806FA-E18TAG1 and 2806FA-E18TAG2 for 400 to 650 kVAH2G4DM15, ALG184, P15G4DE25 and othersTMTL Engines 333W0-EG045
Alternator NANACG/LS/EquivalentNACG / Leroy Somer / Meccalte / Stamford
Enclosure AcousticNAAcousticNAAcoustic
Dimensions (L × W × H) 4700 × 1600 × 2020 mm (axes not stated)NA5800 × 2200 × 2300 mm (axes not stated)4700 × 1600 × 2020 mm (axes not stated)2350 × 1000 × 1425 mm (axes not stated)
Fuel tank capacity 55 to 340NA55 to 80050 to 340100
Weight about 676–4500 kgNA690–3920 kgabout 676–4500 kg1180 kg
Certification
CPCB IV+ YesNANAYesNA
Certifications and standards BS 5514, ISO 3046, ISO 8528ARAIIS/IEC60034-1 (alternator)BS 5514, ISO 3046, ISO 8528ISO 3046-1, ISO 8528
Performance
Governing class A0 (A1 on LP15)NAG2/G3A1 (OL 15, OL 20); A0 (OL 25 to OL 250)CRS Electronic G3
Fuel consumption NANANANANA
Noise level NANANANANA
Controls
Controller GC 902 and GC 1206NAGC 1115 (10 to 200 kVA), GC 1116 (250 and 320 kVA), DSE7320 (400 to 650 kVA)GC 1207 (OL 15), DEIF SGC120 (OL 20), GC 1206 (OL 25 to OL 250)TMTL Genset Control Unit
Support
Warranty NA1 YearStandard warranty of 2 Years/5000 Hours, 5 Years 5C warranty5 Years or 8000 hrs, T&C apply (OL 20: 2 years or 5000 hrs whichever occurs earlier)Warranty period covers 2 Years or 5000 Hours run* (whichever is earlier). Warranty on 5C covers 5 Years or 5000 Hours run* (whichever is earlier). * Terms and conditions apply
Source
NoteSeries of 13 diesel sets from 15 kVA to 250 kVA; each set has its own specification page on the maker's site.Sheet prints the ratings, engine models, tank size and weight for 13 models.
Model codeLP15, LP25, LP30, LP35/40, LP45, LP60, LP75/82.5, LP100, LP125, LP160, LP180, LP250NAM10DR to M650DROL 15, OL 20, OL 25, OL 30, OL 35/40, OL 45, OL 60, OL 82.5, OL 100, OL 125, OL 160, OL 180, OL 250NA
DatasheetSpec page of Ashok Leyland Leypower (opens the maker's site)Spec page of Joyshree Powerol 45 KVA DG Set (opens the maker's site)Datasheet (PDF) of Mahindra Powerol M10DR to M650DR (opens the maker's site)Datasheet (PDF) of Ojus Power and Technologies OL series (opens the maker's site)Spec page of Pinnacle Generators 45 kVA (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026
DetailsDetails of Ashok Leyland LeypowerDetails of Joyshree Powerol 45 KVA DG SetDetails of Mahindra Powerol M10DR to M650DRDetails of Ojus Power and Technologies OL seriesDetails of Pinnacle Generators 45 kVA

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 5 products above, as printed.

  • Rating: 10 to 650 kVA as printed (ranges included)
  • Power output: 8 to 520 kWe as printed (ranges included); 2 not published
  • Rating basis: Prime; 1 of 5 publishes it
  • Fuel: Diesel; 2 of 5 publish it
  • CPCB IV+: 2 of 5; 3 not published
  • Output voltage: 2 of 5 publish it; values in the table
  • Frequency: 50 Hz; 2 of 5 publish it
  • Power factor: 0.8 lag on 1, 0.8 lagging on 1; 3 not published
  • Governing class: 4 of 5 publish it; values in the table
  • Phase: 3 of 5 publish a list; 3-phase on 3, 1-phase on 2
  • Engine: 4 of 5 publish it; values in the table
  • Alternator: 2 of 5 publish it; values in the table
  • Enclosure: Acoustic; 3 of 5 publish it
  • Controller: 4 of 5 publish it; values in the table
  • Dimensions (L × W × H): 4 of 5 publish it; values in the table
  • Fuel tank capacity: 100 on 1, 50 to 340 on 1, 55 to 340 on 1, 55 to 800 on 1; 1 not published
  • Weight: 676 to 4500 kg as printed (ranges included); 1 not published (2 printed as approximate)
  • Warranty: 4 of 5 publish it; values in the table
  • Certifications and standards: 5 of 5 publish a list; ISO 8528 on 3, BS 5514 on 2, ISO 3046 on 2

Questions about 45 kVA DG sets (diesel and gas generator sets)

Which companies make 45 kVA DG sets (diesel and gas generator sets) in India?
5 companies list 5 products at this size: Ashok Leyland (Leypower); Joyshree Powerol (45 KVA DG Set); Mahindra Powerol (M10DR to M650DR); Ojus Power and Technologies (OL series); Pinnacle Generators (45 kVA). They are listed A–Z by company, not ranked.
How do these 45 kVA DG sets (diesel and gas generator sets) differ?
Rating: 10 to 650 kVA as printed (ranges included). Power output: 8 to 520 kWe as printed (ranges included); 2 not published. Rating basis: Prime; 1 of 5 publishes it. Fuel: Diesel; 2 of 5 publish it. Counted from the 5 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 45 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.