5 products from 3 companies, side by side. All 68 products in PCS · Listed A–Z, not ranked · Reviewed November 2026
A 1000 kW (1 MW) PCS is a central converter size used for large industrial sites and for the smaller blocks of utility-scale storage. It usually sits between a battery container and a step-up transformer, and several units are combined for multi-megawatt projects.
1000 kW compared
A–Z by company, not ranked · NA: not published by the maker
| Field | Delta Electronics IndiaPCS1500Central-scale bidirectional storage PCS, 1000-1725 kW, IEC version | FIMERPVS980-58BC-1045kVA-LBidirectional converter, 727–1045 kVA (IEC/UL version, 1 MVA sheet) | FIMERPVS980-58BC-1250-LBidirectional converter, 869–1250 kVA (IEC version, 1250-L sheet) | KehuaBCS1000K~1250K-C-HUD | KehuaBCS1000K~1250K-C-HUD-NP |
|---|---|---|---|---|---|
| AC side | |||||
| Rated power | 1000–1725 kW | 727–1045 kW | 869–1250 kW | 1000–1250 kW | 1000–1250 kW |
| Printed ratings | 1000, 1200, 1500, 1725 kW | 727, 787, 848, 909, 954, 1000, 1045 kW | 869, 941, 1014, 1086, 1141, 1195, 1250 kW | 1000, 1250 kW | 1000, 1250 kW |
| Nominal AC voltage | 400–690 V | 480–690 V | 480–690 V | 690 V | 690 V |
| Grid frequency | 50/60 | 50/60 | 50/60 | 50 | 60 |
| DC side | |||||
| DC voltage range | 623–1500 V | 680–1500 V | 680–1500 V | 1000–1500 V | 1000–1500 V |
| Max DC current | 1666 A | 1091 A | 1325 A | 1403 A | 1403 A |
| Performance | |||||
| Max efficiency | 98.52 % | 98.8 % | 98.8 % | 99 % | 99 % |
| Build | |||||
| Type | NA | NA | NA | Central | Central |
| Cooling | Air | NA | NA | Air | Air |
| Ingress protection | IP55/IP34/IP34 electronics/air duct /connection area | IP66/UL Type 3R | IP55 | IP65 | NEMA 3R |
| Operating temperature | -30–60 °C | -20–50 °C | -20–50 °C | -35–60 °C | -35–60 °C |
| Weight | about 2600 kg | about 2500 kg | up to 1800 kg | 950 kg | 950 kg |
| MV transformer built in | No | No | No | No | No |
| Communication | NA | Ethernet, Modbus (type not stated) | Ethernet, Modbus (type not stated), Profinet | RS485, CAN, Ethernet, Modbus RTU, Modbus TCP, IEC 61850 | RS485, CAN, Ethernet, Modbus TCP, IEC 61850 |
| Grid functions | |||||
| Off-grid / black start | Not stated | Not stated | Not stated | Yes | Yes |
| Grid-forming | Not stated | Not stated | Not stated | Yes | Yes |
| Certification | |||||
| Certifications | IEC 62477, IEC 61000-6-2, IEC 61000-6-4, VDE AR-N 4110, G99 | NA | CE, IEC 62477-1, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 61683, EN 50530, IEC 61727, IEC 62116, IEC 62910 | EN/IEC 62477-1, EN/IEC 61000-6-2, EN 50549-2/10, IEC 62116, IEC 61727, IEC 60068-2-1/2/14/30, EN 55011 | UL 1741, CSA C22.2No 107.1-16, CFR 47 Part 15(2022)CLASS A, ANSI C63.4+A1, IEEE 1547, Rule 14, Rule 21 |
| Source | |||||
| Note | Rated at 25 °C; 769–1105 kVA at 50 °C. | ||||
| Model code | EPCS1000-IEC, EPCS1200-IEC, EPCS1500-IEC, EPCS1725-IEC | PVS980-58BC-727kVA-E, -787kVA-F, -848kVA-G, -909kVA-I, -954kVA-J, -1000kVA-K, -1045kVA-L | PVS980-58BC-869-E, -941-F, -1014-G, -1086-I, -1141-J, -1195-K, -1250-L | BCS1000K-C-HUD, BCS1250K-C-HUD | BCS1000K-C-HUD-NP, BCS1250K-C-HUD-NP |
| Datasheet | Datasheet (image) of Delta Electronics India PCS1500 (opens the maker's site) | Datasheet (PDF) of FIMER PVS980-58BC-1045kVA-L (opens the maker's site) | Datasheet (PDF) of FIMER PVS980-58BC-1250-L (opens the maker's site) | Spec page of Kehua BCS1000K~1250K-C-HUD (opens the maker's site) | Spec page of Kehua BCS1000K~1250K-C-HUD-NP (opens the maker's site) |
| CheckedFigures compared with the maker's sheet | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 |
| Details | Details of Delta Electronics India PCS1500 | Details of FIMER PVS980-58BC-1045kVA-L | Details of FIMER PVS980-58BC-1250-L | Details of Kehua BCS1000K~1250K-C-HUD | Details of Kehua BCS1000K~1250K-C-HUD-NP |
Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.
What differs between them
Counted from the 5 products above, as printed.
- Rated power: 727 to 1725 kW as printed (ranges included)
- DC voltage range: 623 to 1500 V as printed (ranges included)
- Max DC current: 1091 to 1666 A as printed
- Nominal AC voltage: 400 to 690 V as printed (ranges included)
- Grid frequency: 3 50/60, 1 50, 1 60
- Max efficiency: 98.52 to 99 % as printed
- Type: Central; 2 of 5 publish it
- Cooling: Air; 3 of 5 publish it
- Ingress protection: 5 of 5 publish it; values in the table
- Operating temperature: -35 to 60 °C as printed (ranges included)
- Weight: 950 to 2600 kg as printed (2 printed as approximate, 1 printed as an upper bound)
- MV transformer built in: 0 of 5
- Off-grid / black start: 2 of 5; 3 not published
- Grid-forming: 2 of 5; 3 not published
- Communication: 4 of 5 publish a list; Ethernet on 4, CAN on 2, IEC 61850 on 2, Modbus (type not stated) on 2
- Certifications: 4 of 5 publish a list; IEC 61727 on 2, IEC 62116 on 2
Nearby power values
A page needs 3+ products from 3+ companies; values without one are in the full list by power.
- 941 kW1 product
- 954 kW1 product
- 1045 kW1 product
- 1086 kW1 product
Questions about 1 MW (1000 kW) PCS (power conversion systems)
- Which companies make 1 MW (1000 kW) PCS (power conversion systems) in India?
- 3 companies list 5 products at this size: Delta Electronics India (PCS1500); FIMER (PVS980-58BC-1045kVA-L, PVS980-58BC-1250-L); Kehua (BCS1000K~1250K-C-HUD, BCS1000K~1250K-C-HUD-NP). They are listed A–Z by company, not ranked.
- How do these 1 MW (1000 kW) PCS (power conversion systems) differ?
- Rated power: 727 to 1725 kW as printed (ranges included). DC voltage range: 623 to 1500 V as printed (ranges included). Max DC current: 1091 to 1666 A as printed. Nominal AC voltage: 400 to 690 V as printed (ranges included). Counted from the 5 products as each maker prints them.
- Where do these figures come from?
- From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 1000 kW are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.
Is your company on this list? Add it, update your details or raise a concern →