FIMER PVS980-58BC-1045kVA-L

Listed A–Z, not ranked · Reviewed November 2026

Bidirectional converter, 727–1045 kVA (IEC/UL version, 1 MVA sheet) · PCS by FIMER

As printed in the datasheet, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.

AC side

Rated power
727–1045 kW
Printed ratings
727, 787, 848, 909, 954, 1000, 1045 kW
Nominal AC voltage
480–690 V
Grid frequency
50/60

DC side

DC voltage range
680–1500 V
Max DC current
1091 A

Performance

Max efficiency
98.8 %

Build

Type
NA
Cooling
NA
Ingress protection
IP66/UL Type 3R
Operating temperature
-20–50 °C
Weight
about 2500 kg
MV transformer built in
No
Communication
Ethernet, Modbus (type not stated)

Grid functions

Off-grid / black start
Not stated
Grid-forming
Not stated

Certification

Certifications
NA
Size:
1000 kW
, +6 other sizes
Model code:
PVS980-58BC-727kVA-E, -787kVA-F, -848kVA-G, -909kVA-I, -954kVA-J, -1000kVA-K, -1045kVA-L
Checked:
November 2026, against the datasheet

Full datasheet

Every row the maker prints, copied as written, read 2026-11-15.

Overview

Product
Bidirectional converterPVS980-58BCPVS980-58BCPVS980-58BC IEC & UL version(fimer.com)
Models
PVS980-58BC-727kVA-E, PVS980-58BC-787kVA-F, PVS980-58BC-848kVA-G, PVS980-58BC-909kVA-I, PVS980-58BC-954kVA-J, PVS980-58BC-1000kVA-K, PVS980-58BC-1045kVA-L
Description
aimed at large-scale grid connected energy storage applicationsbased on the world’s leading converter platform used also in FIMER solar invertersideal for multi-megawatt energy storage systems, providing maximum grid stability for power plants with intermittent energy sources
Power range
From 727 to 1045 kVAThe converters are available from 727 kVA up to 1045 kVA.The converters are available from 1454 kVA up to 2091 kVA.(fimer.com)
Sheet version
PVS980-58BC bidirectional converter_EN REV. C 14-04.2020

DC side

DC voltage range
PVS980-58BC-727kVA-E: 680 to 1500 V; PVS980-58BC-787kVA-F: 737 to 1500 V; PVS980-58BC-848kVA-G: 794 to 1500 V; PVS980-58BC-909kVA-I: 850 to 1500 V; PVS980-58BC-954kVA-J: 893 to 1500 V; PVS980-58BC-1000kVA-K: 935 to 1500 V; PVS980-58BC-1045kVA-L: 978 to 1500 V
Full-power DC voltage range at 50 °C
PVS980-58BC-727kVA-E: 680 to 1100 V; PVS980-58BC-787kVA-F: 737 to 1100 V; PVS980-58BC-848kVA-G: 794 to 1100 V; PVS980-58BC-909kVA-I: 850 to 1100 V; PVS980-58BC-954kVA-J: 893 to 1100 V; PVS980-58BC-1000kVA-K: 935 to 1100 V; PVS980-58BC-1045kVA-L: 978 to 1100 V
Max. DC voltage
1500 V
Max. DC current at 35 °C
1200 A
Max. DC current at 50 °C
1091 A
Max. DC short-circuit current per input
73 kApeak, 17 MA2s, external aR fuses required between converter and BES
Number of DC inputs
6 inputs, as option 8, 12 inputs or 16 inputs (+/-) and DC input current measurement
DC grounding
Floating only

AC side

AC power at 35 °C
PVS980-58BC-727kVA-E: 800 kVA; PVS980-58BC-787kVA-F: 866 kVA; PVS980-58BC-848kVA-G: 933 kVA; PVS980-58BC-909kVA-I: 1000 kVA; PVS980-58BC-954kVA-J: 1050 kVA; PVS980-58BC-1000kVA-K: 1100 kVA; PVS980-58BC-1045kVA-L: 1150 kVA
AC power at 50 °C
PVS980-58BC-727kVA-E: 727 kVA; PVS980-58BC-787kVA-F: 787 kVA; PVS980-58BC-848kVA-G: 848 kVA; PVS980-58BC-909kVA-I: 909 kVA; PVS980-58BC-954kVA-J: 954 kVA; PVS980-58BC-1000kVA-K: 1000 kVA; PVS980-58BC-1045kVA-L: 1045 kVA
Nominal AC voltage
PVS980-58BC-727kVA-E: 480 V; PVS980-58BC-787kVA-F: 520 V; PVS980-58BC-848kVA-G: 560 V; PVS980-58BC-909kVA-I: 600 V; PVS980-58BC-954kVA-J: 630 V; PVS980-58BC-1000kVA-K: 660 V; PVS980-58BC-1045kVA-L: 690 V
Grid frequency
50/60 Hz
Max. AC current at 35 °C
962 A
Max. AC current at 50 °C
875 A
Power factor
Four quadrant
Current harmonic distortion (THDi)
< 3%
Grid type
IT

Efficiency

Max. efficiency
PVS980-58BC-727kVA-E: 98.6%; PVS980-58BC-787kVA-F: 98.7%; PVS980-58BC-848kVA-G: 98.7%; PVS980-58BC-909kVA-I: 98.8%; PVS980-58BC-954kVA-J: 98.8%; PVS980-58BC-1000kVA-K: 98.8%; PVS980-58BC-1045kVA-L: 98.8%

Grid support

Grid support
Reactive power compensation, Power reduction, LVRT, HVRT, FqRT, Anti-islanding
Grid functions
YesYes

Protection

DC protection and disconnection
as option
AC protection and disconnection
as option
AC surge protection
Type 2 as standard. High Energy Type 1 as option
DC surge protection
Type 2 as standard. High Energy Type 1 as option
Ground fault / insulation monitoring
Yes
DC reverse polarity
Yes
Short circuit and overcurrent
Yes
Overvoltage and overtemperature
Yes
Anti-islanding
Yes
Grid monitoring
Yes

Environment

Ambient temperature range (nominal ratings)
-20 °C to +50 °C
Max. ambient temperature
+60 °C
Relative humidity
5% to 100%
Max. altitude
4000 m
Ingress protection
IP66/UL Type 3R
Noise
88 dBA

Physical

Dimensions W / H / D (mm)
2181/2443/1522
Weight
2500 kg

Auxiliary power

Own consumption in operation
≤ 1500 W
Standby consumption
≤ 235 W
Auxiliary supply
External, 1 phase auxiliary power input

Communication

Communication
Modbus, Ethernet
Display / user interface
Local control panel
Inputs / outputs
2 as standard7/1 as standard

Certifications

Certifications and standards
IEC, CEA
Safety standards
CE according to LV and EMC directives

Features

Features
Like FIMER central inverters, the PVS980-58BC bidirectional converter has been developed on the basis of decades of experience in the industry and proven technology platform. Unrivalled expertise from the world’s market and technology leader in frequency converters is the hallmark of the PVS980-58BC series.For power plants combining photovoltaics and energy storage, the common platform shared with PVS980-58BC bidirectional converter and PVS980-58BC central inverter brings synergies in both the availability of service and support personnel and the spare part logistics.The high DC input voltage, high efficiency, proven components, compact and modular design and a host of life cycle services available ensure FIMER PVS980-58BC bidirectional converters provide a rapid return on investment.High total performance; Outstanding endurance for outdoor use; Full four quadrant active power and reactive power support; High DC input voltage up to 1500 VDC for minimizing system cost; Self-contained cooling system suitable for harsh environments; Compact, modular product design; Life cycle service and support through FIMER’s extensive global service networkFIMER supports its customers with a dedicated global service network and provides a complete range of life cycle services from installation and commissioning to preventative maintenance, spare parts, repairs and recycling.High total performance; Outstanding endurance for outdoor use; Full four quadrant active power and reactive power support; High DC input voltage up to 1500 VDC for minimizing system cost; Self-contained cooling system suitable for harsh environments; Compact, modular product design; Life cycle service and support through FIMER’s extensive global service network(fimer.com)
Options and accessories
AC breaker; AC disconnector switch; DC disconnector switch; Heavy duty (Type 1) surge protection; AC busbar interface; Internal auxiliary power supply; Fieldbus and Ethernet connections; High altitude version; Low temperature version; Warranty extensions; Converter care contractsMedium voltage station (transformer and switchgear) as outdoor or containerised solution; Remote monitoring solutions
Diagrams
PVS980-58BC, 0.7 - 1.04MVABattery system (BMS), Ext. fuses, PVS980-58BC, PVS980-MVP, Transformer, SafeRing switchgear, MV grid connection; EMS, SCADA, Local service PC, Remote monitoring, Internet, Mobile, Web, Database

More PCS from FIMER

FIMER PVS980-58BC-1045kVA-L, in short

The FIMER PVS980-58BC-1045kVA-L is a PCS rated 727 kW, with max efficiency 98.8% and MV transformer built in: no. Its max efficiency (98.8%) is above the median of the 45 PCS listed (98.7%). FIMER has 5 other PCS on this site.

Questions about the FIMER PVS980-58BC-1045kVA-L

What are the main specifications of the FIMER PVS980-58BC-1045kVA-L?
Rated 727 kW; Max efficiency 98.8%; MV transformer built in: no. As printed on FIMER's datasheet (checked November 2026); the full list is on this page.
Where can I find the FIMER PVS980-58BC-1045kVA-L datasheet?
FIMER publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
Who makes the FIMER PVS980-58BC-1045kVA-L?
FIMER. It has 6 PCS on this site, including this one.

Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.

Values as FIMER prints them in the linked datasheet; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with FIMER. Product and company names are trademarks of their owners, used only to identify the product.

Not sure what to buy? Ask us what's compatible and what size fits your site.