Listed A–Z, not ranked · Reviewed November 2026
Remote I/O and PLCs products
- Type
- PLC
- Max I/O
- NA
- Protocols
- NA
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- NA
- Protocols
- EtherCAT, EtherNet/IP, PROFINET
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 64 units
- Protocols
- EtherNet/IP
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- NA
- Protocols
- Modbus RTU
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 64 units
- Protocols
- PROFINET
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- DIO: Max. 4,352 points; AIO: Max. 544 channels; RIO>100,000 points
- Protocols
- Modbus RTU, Modbus TCP, EtherNet/IP
- Programming languages
- LD, SFC, FBD, IL, ST
- Redundancy
- Yes
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- DIO: Max. 4,352 points; AIO: Max. 544 channels; RIO>100,000 points
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 1,024
- Protocols
- Modbus TCP, EtherNet/IP, CANopen
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 1,024
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- NA
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 256 points (256 inputs / 256 outputs)
- Protocols
- CANopen
- Programming languages
- LD, ST, SFC, CFC
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 494 (14 + 480)
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 256 points of digital I/O modules; 8 DVP-S series analog I/O modules
- Protocols
- Modbus RTU
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 128 DI points and 128 DO points
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 256 points of digital I/O modules; 8 DVP-S series analog I/O modules
- Protocols
- Modbus TCP, Modbus RTU
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 48 I/Os (32 Digital Inputs & 16 Digital Outputs)
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- -10–55 °C
- Type
- PLC
- Max I/O
- 60 I/Os (24DI + 20DO + 8AI + 8AO)
- Protocols
- NA
- Programming languages
- LD, FBD
- Redundancy
- NA
- Operating temperature
- -20–55 °C
- Type
- PLC
- Max I/O
- 112 IOS
- Protocols
- Modbus RTU
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 16 digital inputs (CAN-DI16)
- Protocols
- CANopen
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- 0–70 °C
- Type
- Remote I/O
- Max I/O
- 8 digital inputs (MOD-DI-8)
- Protocols
- Modbus RTU
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- 0–70 °C
- Type
- PLC
- Max I/O
- NA
- Protocols
- Modbus TCP, Modbus RTU, PROFINET, EtherNet/IP, EtherCAT, CANopen, OPC UA, MQTT, IEC 60870-5-104
- Programming languages
- ST, SFC, FBD, LD, CFC, IL
- Redundancy
- NA
- Operating temperature
- 0–60 °C
- Type
- PLC
- Max I/O
- 64 I/O modules
- Protocols
- Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, OPC UA, MQTT, IEC 60870-5-104
- Programming languages
- ST, LD, SFC, FBD, CFC
- Redundancy
- Yes
- Operating temperature
- 0–60 °C
- Type
- PLC
- Max I/O
- 128 I/O modules
- Protocols
- Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT, CANopen, OPC UA, MQTT, IEC 60870-5-104
- Programming languages
- ST, LD, SFC, FBD, CFC
- Redundancy
- Yes
- Operating temperature
- -20–60 °C
- Type
- PLC
- Max I/O
- 128 I/O modules
- Protocols
- Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT, OPC UA, MQTT, IEC 60870-5-104, DNP3
- Programming languages
- ST, LD, SFC, FBD, CFC
- Redundancy
- Yes
- Operating temperature
- 0–60 °C
- Type
- Remote I/O
- Max I/O
- 22 I/O modules in a single rack
- Protocols
- Modbus TCP
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- 0–60 °C
- Type
- Remote I/O
- Max I/O
- 22 I/O modules in a single rack
- Protocols
- PROFIBUS
- Programming languages
- NA
- Redundancy
- Yes
- Operating temperature
- 0–60 °C
- Type
- PLC
- Max I/O
- less than 80 I/O points (on-board + local + remote)
- Protocols
- Modbus TCP, Modbus RTU, MQTT
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- Max. 512 pts including CC-Link, AnyWireASLINK, and Bitty series remote I/O (FX5U, FX5UC); Max. 256 pts (FX5UJ)
- Protocols
- Modbus (type not stated)
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 4096 points (X/Y)
- Protocols
- NA
- Programming languages
- LD, ST, FBD, SFC
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 256 I/O (FX3G, FX3S range) or 384 I/O (FX3U, FX3UC range) extension devices, including CC-Link remote I/O
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 1024 points (L02SCPU, L02CPU); 4096 points (L06CPU, L26CPU, L26CPU-BT)
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 1024 points (Q00UCPU, Q01UCPU); 2048 points (Q02UCPU); 4096 points (other models listed)
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 8xAI (FIOA-0800-L-B); 4xAI + 2xAO (FIOA-0402-U-B)
- Protocols
- Modbus RTU
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 16 DI (bi-directional) or 16 DO per module (variants: 8+8, 4+4, 16 DI, 16 DO, 8 DO)
- Protocols
- Modbus RTU
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- Up to 8 Slots (Digital and Analog)
- Protocols
- NA
- Programming languages
- LD, SFC, IL, FBD, ST
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 16 Expansions modules, 256 I/O ports
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- Remote I/O
- Max I/O
- NA
- Protocols
- NA
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- Remote I/O
- Max I/O
- 264 digital I/O; 114 analog I/O
- Protocols
- EtherNet/IP, Modbus TCP, Modbus (type not stated), CANopen
- Programming languages
- NA
- Redundancy
- NA
- Operating temperature
- NA
- Type
- PLC
- Max I/O
- 3 I/O slots (card configurations)
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 4 I/O slots (card configurations)
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 2 I/O slots
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 2 I/O slots
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 4 I/O slots
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 6 I/O slots
- Protocols
- Modbus RTU, Modbus TCP, MQTT
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 2 I/O slots
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 6 I/O slots
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 6 inputs / 4 relay outputs
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 6 + 2 inputs / 5 relay outputs
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 8 inputs / 6 outputs
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
- Type
- PLC
- Max I/O
- 3 + 1 inputs / 2 relay outputs
- Protocols
- Modbus RTU
- Programming languages
- LD
- Redundancy
- NA
- Operating temperature
- 0–55 °C
| Details | Redundancy | Add to plan, favourite | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Ambivert Technologies | Autoemx PLCPLC with built-in 2.8 inch touch HMI | PLC | NA | NA | LD | NA | NA | ||
| Autonics India | ADIO-ILM | Remote I/O | NA | EtherCAT, EtherNet/IP, PROFINET | NA | NA | NA | ||
| Autonics India | ARIO-C-EI | Remote I/O | 64 units | EtherNet/IP | NA | NA | NA | ||
| Autonics India | ARIO-C-MR | Remote I/O | NA | Modbus RTU | NA | NA | NA | ||
| Autonics India | ARIO-C-PN | Remote I/O | 64 units | PROFINET | NA | NA | NA | ||
| Delta Electronics India | AH Series Redundant CPU | PLC | DIO: Max. 4,352 points; AIO: Max. 544 channels; RIO>100,000 points | Modbus RTU, Modbus TCP, EtherNet/IP | LD, SFC, FBD, IL, ST | Yes | NA | ||
| Delta Electronics India | AH Series Standard CPU | PLC | DIO: Max. 4,352 points; AIO: Max. 544 channels; RIO>100,000 points | NA | NA | NA | NA | ||
| Delta Electronics India | AS Series Motion CPU | PLC | 1,024 | Modbus TCP, EtherNet/IP, CANopen | NA | NA | NA | ||
| Delta Electronics India | AS Series Standard CPU | PLC | 1,024 | NA | NA | NA | NA | ||
| Delta Electronics India | DVP-EH3 Series | PLC | NA | NA | NA | NA | NA | ||
| Delta Electronics India | DVP-ES3 Series | PLC | 256 points (256 inputs / 256 outputs) | CANopen | LD, ST, SFC, CFC | NA | NA | ||
| Delta Electronics India | DVP-SX2 Series | PLC | 494 (14 + 480) | NA | NA | NA | NA | ||
| Delta Electronics India | RTU-485 | Remote I/O | 256 points of digital I/O modules; 8 DVP-S series analog I/O modules | Modbus RTU | NA | NA | NA | ||
| Delta Electronics India | RTU-ECAT | Remote I/O | 128 DI points and 128 DO points | NA | NA | NA | NA | ||
| Delta Electronics India | RTU-EN01 | Remote I/O | 256 points of digital I/O modules; 8 DVP-S series analog I/O modules | Modbus TCP, Modbus RTU | NA | NA | NA | ||
| GIC India | Genie NXSmart relay module | PLC | 48 I/Os (32 Digital Inputs & 16 Digital Outputs) | Modbus RTU | LD | NA | -10–55 °C | ||
| GIC India | Genie Pro | PLC | 60 I/Os (24DI + 20DO + 8AI + 8AO) | NA | LD, FBD | NA | -20–55 °C | ||
| GIC India | PL-100Mini PLC | PLC | 112 IOS | Modbus RTU | NA | NA | NA | ||
| Messung Systems | CANopen Remote I/O (CAN-DI16 and family) | Remote I/O | 16 digital inputs (CAN-DI16) | CANopen | NA | NA | 0–70 °C | ||
| Messung Systems | Modbus RTU Remote I/OMOD-DI-8 and family | Remote I/O | 8 digital inputs (MOD-DI-8) | Modbus RTU | NA | NA | 0–70 °C | ||
| Messung Systems | NX-ERA Xpress | PLC | NA | Modbus TCP, Modbus RTU, PROFINET, EtherNet/IP, EtherCAT, CANopen, OPC UA, MQTT, IEC 60870-5-104 | ST, SFC, FBD, LD, CFC, IL | NA | 0–60 °C | ||
| Messung Systems | NX3005 | PLC | 64 I/O modules | Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, OPC UA, MQTT, IEC 60870-5-104 | ST, LD, SFC, FBD, CFC | Yes | 0–60 °C | ||
| Messung Systems | NX3008 | PLC | 128 I/O modules | Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT, CANopen, OPC UA, MQTT, IEC 60870-5-104 | ST, LD, SFC, FBD, CFC | Yes | -20–60 °C | ||
| Messung Systems | NX3030 | PLC | 128 I/O modules | Modbus RTU, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT, OPC UA, MQTT, IEC 60870-5-104, DNP3 | ST, LD, SFC, FBD, CFC | Yes | 0–60 °C | ||
| Messung Systems | NX5100 / NX5101 MODBUS TCP Head | Remote I/O | 22 I/O modules in a single rack | Modbus TCP | NA | NA | 0–60 °C | ||
| Messung Systems | NX5110 / NX5210 PROFIBUS-DP Head | Remote I/O | 22 I/O modules in a single rack | PROFIBUS | NA | Yes | 0–60 °C | ||
| Messung Systems | XMPro-10 | PLC | less than 80 I/O points (on-board + local + remote) | Modbus TCP, Modbus RTU, MQTT | LD | NA | 0–55 °C | ||
| Mitsubishi Electric India | MELSEC iQ-F SeriesCPU modules FX5U, FX5UC, FX5UJ, FX5S | PLC | Max. 512 pts including CC-Link, AnyWireASLINK, and Bitty series remote I/O (FX5U, FX5UC); Max. 256 pts (FX5UJ) | Modbus (type not stated) | NA | NA | NA | ||
| Mitsubishi Electric India | MELSEC iQ-R Series CPU modules | PLC | 4096 points (X/Y) | NA | LD, ST, FBD, SFC | NA | NA | ||
| Mitsubishi Electric India | MELSEC-F SeriesFX main units (FX3 range) | PLC | 256 I/O (FX3G, FX3S range) or 384 I/O (FX3U, FX3UC range) extension devices, including CC-Link remote I/O | NA | NA | NA | NA | ||
| Mitsubishi Electric India | MELSEC-L Series CPU modules | PLC | 1024 points (L02SCPU, L02CPU); 4096 points (L06CPU, L26CPU, L26CPU-BT) | NA | NA | NA | NA | ||
| Mitsubishi Electric India | MELSEC-Q Series Universal model QCPU | PLC | 1024 points (Q00UCPU, Q01UCPU); 2048 points (Q02UCPU); 4096 points (other models listed) | NA | NA | NA | NA | ||
| Renu Electronics | Field I/O FIOA Analog Units | Remote I/O | 8xAI (FIOA-0800-L-B); 4xAI + 2xAO (FIOA-0402-U-B) | Modbus RTU | NA | NA | NA | ||
| Renu Electronics | Field I/O FL001D Units (V3) | Remote I/O | 16 DI (bi-directional) or 16 DO per module (variants: 8+8, 4+4, 16 DI, 16 DO, 8 DO) | Modbus RTU | NA | NA | NA | ||
| Renu Electronics | FlexiLogics FL004 V2 (Eco Series) | PLC | Up to 8 Slots (Digital and Analog) | NA | LD, SFC, IL, FBD, ST | NA | 0–55 °C | ||
| Renu Electronics | FlexiLogics FL055 V2 / FL005 V2Standard Series | PLC | 16 Expansions modules, 256 I/O ports | NA | NA | NA | 0–55 °C | ||
| Renu Electronics | FlexiLogics FLD / FLA Expansion I/O (V2) | Remote I/O | NA | NA | NA | NA | NA | ||
| Schneider Electric India | Modicon TM3 expansion I/O | Remote I/O | 264 digital I/O; 114 analog I/O | EtherNet/IP, Modbus TCP, Modbus (type not stated), CANopen | NA | NA | NA | ||
| Selec Controls | Flexys GT35Compact PLC with 3.5 inch resistive touchscreen | PLC | 3 I/O slots (card configurations) | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | Flexys Panel TX4 / Flexys RailCompact PLC with built-in HMI, flexible I/O cards | PLC | 4 I/O slots (card configurations) | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | MiBRX 2MModular PLC with pluggable or independent display | PLC | 2 I/O slots | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | MiBRX 48x96Modular PLC, panel mount 48 x 96 mm | PLC | 2 I/O slots | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | MiBRX 4MModular PLC with pluggable or independent display | PLC | 4 I/O slots | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | MiBRX 6MModular PLC with optional Ethernet | PLC | 6 I/O slots | Modbus RTU, Modbus TCP, MQTT | LD | NA | 0–55 °C | ||
| Selec Controls | MiBRX 72x72Modular PLC, panel mount 72 x 72 mm | PLC | 2 I/O slots | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | MiBRX 96x96Modular PLC, panel mount 96 x 96 mm | PLC | 6 I/O slots | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | TWIX-1Compact PLC with built-in HMI | PLC | 6 inputs / 4 relay outputs | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | TWIX-2Compact PLC with built-in HMI | PLC | 6 + 2 inputs / 5 relay outputs | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | TWIX-3Compact PLC with built-in HMI | PLC | 8 inputs / 6 outputs | Modbus RTU | LD | NA | 0–55 °C | ||
| Selec Controls | UNIX-1Compact PLC with built-in HMI | PLC | 3 + 1 inputs / 2 relay outputs | Modbus RTU | LD | NA | 0–55 °C |
65 products
Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.
Is your company on this list? Add it, update your details or raise a concern →
New to remote I/O and PLCs? What they are, and what each spec means
Remote I/O modules bring breaker positions, alarms and analogue signals into a control system, and send commands back out. PLCs run local logic, such as interlocks and load shedding. The companies below supply I/O and PLCs widely used at Indian energy and industrial sites.
What to compare before you choose
- Signal types and counts: digital in and out, analogue, temperature inputs.
- Protocol support: Modbus TCP/RTU, IEC 61850, IEC 60870-5-104 or vendor fieldbuses.
- Operating temperature and electrical immunity for substation or outdoor panels.
- Programming tools and how easy it is for another engineer to maintain the logic.
- Local stock and support.
65 products from 12 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.