10 mm² solar DC cables in India

13 products from 9 companies, side by side. All 129 products in Solar and power cables · Listed A–Z, not ranked · Reviewed November 2026

10 mm² solar DC cable carries combined current from several strings, or long runs where voltage drop matters, for example to a combiner box or a central inverter. Check the voltage rating and the outer sheath for UV and weather resistance.

10 mm² compared

A–Z by company, not ranked · NA: not published by the maker

Compare these (12)
A comparison holds 12; hide some to choose which.
FieldAPAR IndustriesE-Beam irradiated ATC / XLPO solar cableSolar DC cable, electron beam cross-linked, as per BS EN 50618/2014 and IEC 62930/2017Dynamic CablesSolar DC CableSingle core photovoltaic cable, EN 50618 / IS 17293:2020 / IEC 62930Finolex CablesSolar Endura PV CablesSingle-conductor tinned copper PV string cable, electron-beam cross-linkedKEI IndustriesCables for Photovoltaics (Solar Cables)KEI IndustriesPV Solar CablesLAPP IndiaÖLFLEX SOLAR XLR-ELAPP IndiaÖLFLEX SOLAR XLR-I5Polycab IndiaPolycab Solar H1Z2Z2-K BSEN 50618Photovoltaic power cable, halogen free, flame retardantPolycab IndiaPolycab Solar H1Z2Z2-K BSEN 50618-ATPhotovoltaic power cable, halogen free, flame retardant, anti termiteRolliflex CablesSolar CablesRR KabelSolar Cable – EN 50618RR KabelSolar Cable – IS 17293Thermo CablesSolar Photovoltaic Cables
General
Type Solar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DC
Construction
Conductor Tinned copperNATinned copperTinned copperTinned copperNANATinned copperTinned copperTinned copperTinned copperTinned copperTinned copper
Cross-section 2.5–300 mm²1.5–400 mm²1.5–400 mm²1.5–240 mm²1.5–240 mm²4–16 mm²1.5–300 mm²2.5–240 mm²2.5–240 mm²1.5–120 mm²1.5–240 mm²1.5–400 mm²2.5–16 mm²
Printed cross-sections 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm²4, 6, 10, 16 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm²2.5, 4.0, 6.0, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm²2.5, 4.0, 6.0, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm²1.50, 2.50, 4.00, 6.00, 10.00, 16.00, 25.00, 35.00, 50.00, 70.00, 95.00, 120.00 mm²1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 185.0, 240.0 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²2.5, 4.0, 6.0, 10.0, 16.0 mm²
Cores Single coreSingle coreSingle-conductorNASingle core11Single coreSingle coreNANANANA
Insulation XLPO (electron beam cross-linked polyolefin co-polymer)Halogen-free cross-linked polyolefin (XLPO), electron beam cross-linkedElectron Beam Cross-Linked Halogen-free & Flame Retardant Compound (XLPO)Cross linked halogen-free polyolefinCrosslinked halogen free & flame retardantElectron beam cross-linked polymer compoundElectron beam cross-linked polymer compoundE-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)Halogen free cross linked XLPO (LSZH XL) compoundUV resistant, cross linkable, halogen free, flame retardant compoundUV resistant crosslinked halogen free flame retardantElectron Beam Irradiated Cross linked Polyolefin Compound
Sheath XLPO (electron beam cross-linked polyolefin co-polymer)Halogen-free XLPO, UV resistantElectron Beam Cross-Linked Halogen-free & Flame Retardant CompoundCross linked halogen-free polyolefinCrosslinked halogen free & flame retardant UV and ozone resistantNANAE-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)Halogen free cross linked XLPO compound in Black or Black/Red colourUV resistant, cross linkable, halogen free, flame retardant compoundUV resistant crosslinked halogen free flame retardantElectron Beam Irradiated Cross linked Polyolefin Compound
Armoured NANANANANANANANANANANANANA
Conductor class Class 5Class 5 (EN 50618 range, tinned copper); IS 17293 range Class 5 tinned or bare copper, Class 2 copper or aluminium from 16 mm²Class 5Class 5Class 5NANAClass 5Class 5Class 5 (EN/IEC 60228)Class 5NAClass 5
Min bending radius > 4 x cable OD4 x overall diameter (fixed installation, EN 50618 column)4x cable diameter (<= 8 mm); 5x cable diameter (8-12 mm); 6x cable diameter (> 12 mm)4 times the diameter6 x OD (fixed), 15 x OD (occasional flexing)NANAFixed installation > 6D; occasionally moved > 8DFixed installation > 15D; occasionally moved > 25DNAFixed installation approx. 4 x cable ØFixed installation approx. 4 x cable ØNA
Electrical
Voltage rating 1.5 kV1.0/1.0 kV AC; 1.5 kV DC1.0/1.0 kV AC; 1.5 kV DC0.6/1.0 kV1.5 kV DC1,8 kV DC; U0/U 1/1 kVNA1500 V DC1500 V DCNAAC 0.6/1.0 kVAC 1.0/1.0 kV1000 V AC / 1500 V DC
Fire performance Flame retardant (EN 60332-1-2); smoke emission (EN 61034-2); halogen free (EN 50525-1)Flame retardant; low smoke; halogen freeFlame non propagation; fire non-propagation; low smoke halogen-free; low corrosive gas emission; low smoke emissionHalogen-free: low smoke emission and low toxicity during fire; flame & fire retardantFlame retardant; low smoke emission; halogen-freeflame-retardant; halogen-freehalogen-freeHalogen free; Flame retardantHalogen free; Flame retardantNAFlame retardant; low smoke; halogen freeFlame retardant; halogen freeNA
Operating temperature -40–120 °C-40–90 °C-40–90 °C-40–90 °C-40–90 °CNANA-40–120 °C-40–120 °CNA-40–90 °C-40–90 °C-40–120 °C
UV resistant YesYesYesYesYesYesNAYesYesNAYesYesNA
Max permissible voltage 1.8 kV1.8 kV DC1.5 kV DC2000 Vdc1.8 kV DCNANA1800 V1800 VNA0.9/1.8 kV DC0.9/1.8 kV DCNA
Test voltage 6.5 kV 50 Hz AC or 15 kV DC for 5 minNA6.5 kVNA6.5 kV AC; 15 kV DCNANA6.5 kV AC 50HzNANAAC 6.5 kV / DC 15 kV (15 min.)NANA
Max conductor temperature NA120 °C120 °C120 °C120 °CNANA120 °C120 °C120 °C120 °CNANA
Ozone resistant YesYesYesYesYesNANAYesYesNAYesYesYes
Chemical resistance NAMineral oil, acid, alkali, ammoniaExcellent (chemical and oil; grease and mineral oil)Mineral oil, ammonia, acidic and alkaline resistance; very good resistance to oil and chemicalsMineral oil, acid and alkaline; very good resistance to oil and chemicalsNANANANANAMineral oil, acid, alkali and ammonia resistantAcid and alkali resistant; ammonia resistantNA
Expected service life 25 years25 years25 years30 years30 yearsNANANANANANANANA
Certification
Standards EN 50618, IEC 62930EN 50618, IS 17293, IEC 62930EN 50618, IEC 62930, IS 172932Pfg 1169/08.2007, BSEN 506182 Pfg 1169/08.2007, EN 50618NANAEN 50618, IEC 62930, UL 4703, IEC 60228EN 50618, IEC 62930, UL 4703, IEC 60228EN 50618, TÜV2PFG1169/08.2007EN 50618IS 17293, IEC 62930TUV-2PIG 1169 / 07 2008, BSEN 50618-2014
Certifications TUVBIS / ISI Mark IS 17293, CE / CPR DoPTÜV RheinlandTÜV, VDE, UTE, IMQNATÜV certifiedNANANANANANANA
Source
Model codeH1Z2Z2-KH1Z2Z2-KH1Z2Z2-KPV1-FPV-F; H1Z2Z2-K1023652 (1x4 black); family articles 1023652-1023655, 1023667-1023670820104000201 (1x1.5 BK), 820104000202 (1x2.5 BK)NANAH1Z2Z2-KNANANA
DatasheetDatasheet (PDF) of APAR Industries E-Beam irradiated ATC / XLPO solar cable (opens the maker's site)Datasheet (PDF) of Dynamic Cables Solar DC Cable (opens the maker's site)Datasheet (PDF) of Finolex Cables Solar Endura PV Cables (opens the maker's site)Datasheet (PDF) of KEI Industries Cables for Photovoltaics (Solar Cables) (opens the maker's site)Spec page of KEI Industries PV Solar Cables (opens the maker's site)Spec page of LAPP India ÖLFLEX SOLAR XLR-E (opens the maker's site)Spec page of LAPP India ÖLFLEX SOLAR XLR-I5 (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618 (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618-AT (opens the maker's site)Spec page of Rolliflex Cables Solar Cables (opens the maker's site)Spec page of RR Kabel Solar Cable – EN 50618 (opens the maker's site)Spec page of RR Kabel Solar Cable – IS 17293 (opens the maker's site)Datasheet (PDF) of Thermo Cables Solar Photovoltaic Cables (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026
DetailsDetails of APAR Industries E-Beam irradiated ATC / XLPO solar cableDetails of Dynamic Cables Solar DC CableDetails of Finolex Cables Solar Endura PV CablesDetails of KEI Industries Cables for Photovoltaics (Solar Cables)Details of KEI Industries PV Solar CablesDetails of LAPP India ÖLFLEX SOLAR XLR-EDetails of LAPP India ÖLFLEX SOLAR XLR-I5Details of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618Details of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618-ATDetails of Rolliflex Cables Solar CablesDetails of RR Kabel Solar Cable – EN 50618Details of RR Kabel Solar Cable – IS 17293Details of Thermo Cables Solar Photovoltaic Cables

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Sizes are the cross-sections each maker prints for a range, so one product covers many sizes; per-size values such as current rating are on the datasheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 13 products above, as printed.

  • Type: Solar DC on all 13
  • Conductor: Tinned copper; 10 of 13 publish it
  • Cross-section: 1.5 to 400 mm² as printed (ranges included)
  • Cores: 8 of 13 publish it; values in the table
  • Voltage rating: 11 of 13 publish it; values in the table
  • Insulation: 13 of 13 publish it; values in the table
  • Sheath: 11 of 13 publish it; values in the table
  • Standards: 11 of 13 publish a list; EN 50618 on 8, IEC 62930 on 6, IS 17293 on 3, IEC 60228 on 2
  • Fire performance: 11 of 13 publish it; values in the table
  • Operating temperature: -40 to 120 °C as printed (ranges included); 3 not published
  • UV resistant: 10 of 13; 3 not published
  • Max permissible voltage: 0.9/1.8 kV DC on 2, 1.8 kV DC on 2, 1800 V on 2, 1.5 kV DC on 1, 1.8 kV on 1, 2000 Vdc on 1; 4 not published
  • Test voltage: 5 of 13 publish it; values in the table
  • Max conductor temperature: 120 °C; 8 of 13 publish it
  • Conductor class: 10 of 13 publish it; values in the table
  • Min bending radius: 9 of 13 publish it; values in the table
  • Ozone resistant: 10 of 13; 3 not published
  • Chemical resistance: 6 of 13 publish it; values in the table
  • Certifications: 5 of 13 publish a list
  • Expected service life: 25 to 30 years as printed; 8 not published

Questions about 10 mm² solar DC cables

Which companies make 10 mm² solar DC cables in India?
9 companies list 13 products at this size: APAR Industries (E-Beam irradiated ATC / XLPO solar cable); Dynamic Cables (Solar DC Cable); Finolex Cables (Solar Endura PV Cables); KEI Industries (Cables for Photovoltaics (Solar Cables), PV Solar Cables); LAPP India (ÖLFLEX SOLAR XLR-E, ÖLFLEX SOLAR XLR-I5); Polycab India (Polycab Solar H1Z2Z2-K BSEN 50618, Polycab Solar H1Z2Z2-K BSEN 50618-AT); Rolliflex Cables (Solar Cables); RR Kabel (Solar Cable – EN 50618, Solar Cable – IS 17293); Thermo Cables (Solar Photovoltaic Cables). They are listed A–Z by company, not ranked.
How do these 10 mm² solar DC cables differ?
Type: Solar DC on all 13. Conductor: Tinned copper; 10 of 13 publish it. Cross-section: 1.5 to 400 mm² as printed (ranges included). Cores: 8 of 13 publish it; values in the table. Counted from the 13 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 10 mm² are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.