300 mm² solar DC cables in India

17 products from 6 companies, side by side. All 129 products in Solar and power cables · Listed A–Z, not ranked · Reviewed November 2026

300 mm² DC cable serves very large DC collection runs in utility plants. Few ranges go this large; compare conductor, insulation and the printed standard.

300 mm² compared

A–Z by company, not ranked · NA: not published by the maker

Compare these (12)
A comparison holds 12; hide some to choose which.
FieldAPAR IndustriesE-Beam irradiated ATC / XLPO solar cableSolar DC cable, electron beam cross-linked, as per BS EN 50618/2014 and IEC 62930/2017Dynamic CablesSolar DC CableSingle core photovoltaic cable, EN 50618 / IS 17293:2020 / IEC 62930Finolex CablesSolar Endura PV CablesSingle-conductor tinned copper PV string cable, electron-beam cross-linkedLAPP IndiaÖLFLEX SOLAR XLR-I5Polycab IndiaPolycab Solar AS NZS 5000 PVCPhotovoltaic power cable, flame retardantPolycab IndiaPolycab Solar AS NZS 5000 PVC-ATPhotovoltaic power cable, flame retardant, anti termitePolycab IndiaPolycab Solar AS NZS 5000 PVC-TwistPhotovoltaic power cable, flame retardant, two single cores twistedPolycab IndiaPolycab Solar AS NZS 5000 PVC-Twist ATPhotovoltaic power cable, flame retardant, two single cores twisted, anti termitePolycab IndiaPolycab Solar AS NZS 5000 RFHPhotovoltaic power cable, halogen free, reduced fire hazardPolycab IndiaPolycab Solar AS NZS 5000 RFH-ATPhotovoltaic power cable, halogen free, reduced fire hazard, anti termitePolycab IndiaPolycab Solar AS NZS 5000 RFH-TwistPhotovoltaic power cable, halogen free, reduced fire hazard, two single cores twistedPolycab IndiaPolycab Solar AS NZS 5000 RFH-Twist ATPhotovoltaic power cable, halogen free, reduced fire hazard, two single cores twisted, anti termitePolycab IndiaPolycab Solar AS NZS 5000 XLPOPhotovoltaic power cable, halogen free, flame retardantPolycab IndiaPolycab Solar AS NZS 5000 XLPO-ATPhotovoltaic power cable, halogen free, flame retardant, anti termitePolycab IndiaPolycab Solar AS NZS 5000 XLPO-TwistPhotovoltaic power cable, halogen free, flame retardant, two single cores twistedPolycab IndiaPolycab Solar AS NZS 5000 XLPO-Twist ATPhotovoltaic power cable, halogen free, flame retardant, two single cores twisted, anti termiteRR KabelSolar Cable – IS 17293
General
Type Solar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DC
Construction
Conductor Tinned copperNATinned copperNAAluminiumAluminiumAluminiumAluminiumAluminiumAluminiumAluminiumAluminiumAluminiumAluminiumAluminiumAluminiumTinned copper
Cross-section 2.5–300 mm²1.5–400 mm²1.5–400 mm²1.5–300 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²120–630 mm²1.5–400 mm²
Printed cross-sections 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²120, 150, 185, 240, 300, 400, 500, 630 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²
Cores Single coreSingle coreSingle-conductor1112211221122NA
Insulation XLPO (electron beam cross-linked polyolefin co-polymer)Halogen-free cross-linked polyolefin (XLPO), electron beam cross-linkedElectron Beam Cross-Linked Halogen-free & Flame Retardant Compound (XLPO)Electron beam cross-linked polymer compoundcross linked halogen free flame retardant materialcross linked halogen free flame retardant materialcross linked halogen free flame retardant materialcross linked halogen free flame retardant materialcross linked halogen free flame retardant materialcross linked halogen free flame retardant materialcross linked halogen free flame retardant materialcross linked halogen free flame retardant materialE-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)UV resistant crosslinked halogen free flame retardant
Sheath XLPO (electron beam cross-linked polyolefin co-polymer)Halogen-free XLPO, UV resistantElectron Beam Cross-Linked Halogen-free & Flame Retardant CompoundNAPolyvinyl ChloridePolyvinyl ChloridePolyvinyl ChloridePolyvinyl ChlorideReduced Fire Hazard MaterialReduced Fire Hazard MaterialReduced Fire Hazard MaterialReduced Fire Hazard MaterialE-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)UV resistant crosslinked halogen free flame retardant
Armoured NANANANANANANANANANANANANANANANANA
Conductor class Class 5Class 5 (EN 50618 range, tinned copper); IS 17293 range Class 5 tinned or bare copper, Class 2 copper or aluminium from 16 mm²Class 5NAClass 2Class 2Class 2Class 2Class 2Class 2Class 2Class 2Class 2Class 2Class 2Class 2NA
Min bending radius > 4 x cable OD4 x overall diameter (fixed installation, EN 50618 column)4x cable diameter (<= 8 mm); 5x cable diameter (8-12 mm); 6x cable diameter (> 12 mm)NAFixed installation > 15D; occasionally moved > 18DFixed installation > 15D; occasionally moved > 18DFixed installation > 15D; occasionally moved > 18DFixed installation > 15D; occasionally moved > 18DFixed installation > 15D; occasionally moved > 25DFixed installation > 15D; occasionally moved > 25DFixed installation > 15D; occasionally moved > 25DFixed installation > 15D; occasionally moved > 25DFixed installation > 6D; occasionally moved > 8DFixed installation > 15D; occasionally moved > 25DFixed installation > 6DFixed installation > 15D; occasionally moved > 25DFixed installation approx. 4 x cable Ø
Electrical
Voltage rating 1.5 kV1.0/1.0 kV AC; 1.5 kV DC1.0/1.0 kV AC; 1.5 kV DCNA1500 V DC1500 V DC1500 V DC1500 V DC1500 V DC1500 V DC1500 V DC1500 V DC1500 V DC1500 V DC1500 V DC1500 V DCAC 1.0/1.0 kV
Fire performance Flame retardant (EN 60332-1-2); smoke emission (EN 61034-2); halogen free (EN 50525-1)Flame retardant; low smoke; halogen freeFlame non propagation; fire non-propagation; low smoke halogen-free; low corrosive gas emission; low smoke emissionhalogen-freeFlame retardantFlame retardantFlame retardantFlame retardantHalogen free; Reduced fire hazardHalogen free; Reduced fire hazardHalogen free; Reduced fire hazardHalogen free; Reduced fire hazardHalogen free; Flame retardantHalogen free; Flame retardantHalogen free; Flame retardantHalogen free; Flame retardantFlame retardant; halogen free
Operating temperature -40–120 °C-40–90 °C-40–90 °CNA-20–90 °C-20–90 °C-20–90 °C-20–90 °C-40–90 °C-40–90 °C-20–90 °C-40–90 °C-40–120 °C-40–120 °C-40–120 °C-40–120 °C-40–90 °C
UV resistant YesYesYesNAYesYesYesYesYesYesYesYesYesYesYesYesYes
Max permissible voltage 1.8 kV1.8 kV DC1.5 kV DCNA1800 V1800 V1800 V1800 V1800 V1800 V1800 V1800 V1800 V1800 V1800 V1800 V0.9/1.8 kV DC
Test voltage 6.5 kV 50 Hz AC or 15 kV DC for 5 minNA6.5 kVNA6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50Hz6.5 kV AC 50HzNA
Max conductor temperature NA120 °C120 °CNA90 °C90 °C90 °C90 °C90 °C90 °C90 °C90 °C120 °C120 °C120 °C120 °CNA
Ozone resistant YesYesYesNAYesYesYesYesYesYesYesYesYesYesYesYesYes
Chemical resistance NAMineral oil, acid, alkali, ammoniaExcellent (chemical and oil; grease and mineral oil)NANANANANANANANANANANANANAAcid and alkali resistant; ammonia resistant
Expected service life 25 years25 years25 yearsNANANANANANANANANANANANANANA
Certification
Standards EN 50618, IEC 62930EN 50618, IS 17293, IEC 62930EN 50618, IEC 62930, IS 17293NAAS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228AS/NZS 5000.1, IEC 62930, UL 4703, EN 50618, IEC 60228AS/NZS 5000.1, IEC 62930, UL 4703, EN 50618, IEC 60228, AS/NZS 3808AS/NZS 5000.1, IEC 62930, UL 4703, EN 50618, IEC 60228, AS/NZS 3808AS/NZS 5000.1, IEC 62930, UL 4703, EN 50618, IEC 60228, AS/NZS 3808IS 17293, IEC 62930
Certifications TUVBIS / ISI Mark IS 17293, CE / CPR DoPTÜV RheinlandNANANANANANANANANANANANANANA
Source
Model codeH1Z2Z2-KH1Z2Z2-KH1Z2Z2-K820104000201 (1x1.5 BK), 820104000202 (1x2.5 BK)NANANANANANANANANANANANANA
DatasheetDatasheet (PDF) of APAR Industries E-Beam irradiated ATC / XLPO solar cable (opens the maker's site)Datasheet (PDF) of Dynamic Cables Solar DC Cable (opens the maker's site)Datasheet (PDF) of Finolex Cables Solar Endura PV Cables (opens the maker's site)Spec page of LAPP India ÖLFLEX SOLAR XLR-I5 (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 PVC (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 PVC-AT (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 PVC-Twist (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 PVC-Twist AT (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 RFH (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 RFH-AT (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 RFH-Twist (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 RFH-Twist AT (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 XLPO (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 XLPO-AT (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 XLPO-Twist (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 XLPO-Twist AT (opens the maker's site)Spec page of RR Kabel Solar Cable – IS 17293 (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026
DetailsDetails of APAR Industries E-Beam irradiated ATC / XLPO solar cableDetails of Dynamic Cables Solar DC CableDetails of Finolex Cables Solar Endura PV CablesDetails of LAPP India ÖLFLEX SOLAR XLR-I5Details of Polycab India Polycab Solar AS NZS 5000 PVCDetails of Polycab India Polycab Solar AS NZS 5000 PVC-ATDetails of Polycab India Polycab Solar AS NZS 5000 PVC-TwistDetails of Polycab India Polycab Solar AS NZS 5000 PVC-Twist ATDetails of Polycab India Polycab Solar AS NZS 5000 RFHDetails of Polycab India Polycab Solar AS NZS 5000 RFH-ATDetails of Polycab India Polycab Solar AS NZS 5000 RFH-TwistDetails of Polycab India Polycab Solar AS NZS 5000 RFH-Twist ATDetails of Polycab India Polycab Solar AS NZS 5000 XLPODetails of Polycab India Polycab Solar AS NZS 5000 XLPO-ATDetails of Polycab India Polycab Solar AS NZS 5000 XLPO-TwistDetails of Polycab India Polycab Solar AS NZS 5000 XLPO-Twist ATDetails of RR Kabel Solar Cable – IS 17293

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Sizes are the cross-sections each maker prints for a range, so one product covers many sizes; per-size values such as current rating are on the datasheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 17 products above, as printed.

  • Type: Solar DC on all 17
  • Conductor: 12 Aluminium, 3 Tinned copper; 2 not published
  • Cross-section: 1.5 to 630 mm² as printed (ranges included)
  • Cores: 16 of 17 publish it; values in the table
  • Voltage rating: 16 of 17 publish it; values in the table
  • Insulation: 17 of 17 publish it; values in the table
  • Sheath: 16 of 17 publish it; values in the table
  • Standards: 16 of 17 publish a list; EN 50618 on 15, AS/NZS 5000.1 on 12, IEC 60228 on 12, AS/NZS 3808 on 11
  • Fire performance: 17 of 17 publish it; values in the table
  • Operating temperature: -40 to 120 °C as printed (ranges included); 1 not published
  • UV resistant: 16 of 17; 1 not published
  • Max permissible voltage: 1800 V on 12, 0.9/1.8 kV DC on 1, 1.5 kV DC on 1, 1.8 kV on 1, 1.8 kV DC on 1; 1 not published
  • Test voltage: 14 of 17 publish it; values in the table
  • Max conductor temperature: 90 to 120 °C as printed; 3 not published
  • Conductor class: 15 of 17 publish it; values in the table
  • Min bending radius: 16 of 17 publish it; values in the table
  • Ozone resistant: 16 of 17; 1 not published
  • Chemical resistance: 3 of 17 publish it; values in the table
  • Certifications: 3 of 17 publish a list
  • Expected service life: 25 years; 3 of 17 publish it

Questions about 300 mm² solar DC cables

Which companies make 300 mm² solar DC cables in India?
6 companies list 17 products at this size: APAR Industries (E-Beam irradiated ATC / XLPO solar cable); Dynamic Cables (Solar DC Cable); Finolex Cables (Solar Endura PV Cables); LAPP India (ÖLFLEX SOLAR XLR-I5); Polycab India (Polycab Solar AS NZS 5000 PVC, Polycab Solar AS NZS 5000 PVC-AT, Polycab Solar AS NZS 5000 PVC-Twist, Polycab Solar AS NZS 5000 PVC-Twist AT, Polycab Solar AS NZS 5000 RFH, Polycab Solar AS NZS 5000 RFH-AT, Polycab Solar AS NZS 5000 RFH-Twist, Polycab Solar AS NZS 5000 RFH-Twist AT, Polycab Solar AS NZS 5000 XLPO, Polycab Solar AS NZS 5000 XLPO-AT, Polycab Solar AS NZS 5000 XLPO-Twist, Polycab Solar AS NZS 5000 XLPO-Twist AT); RR Kabel (Solar Cable – IS 17293). They are listed A–Z by company, not ranked.
How do these 300 mm² solar DC cables differ?
Type: Solar DC on all 17. Conductor: 12 Aluminium, 3 Tinned copper; 2 not published. Cross-section: 1.5 to 630 mm² as printed (ranges included). Cores: 16 of 17 publish it; values in the table. Counted from the 17 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 300 mm² are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.