240 mm² solar DC cables in India
22 products from 7 companies, side by side. All 129 products in Solar and power cables · Listed A–Z, not ranked · Reviewed November 2026
240 mm² solar DC cable is used for the largest DC feeders in utility-scale plants, mostly in aluminium. Check the standard, voltage rating and the installation the maker prints it for.
240 mm² compared
A–Z by company, not ranked · NA: not published by the maker
| Field | APAR IndustriesE-Beam irradiated ATC / XLPO solar cableSolar DC cable, electron beam cross-linked, as per BS EN 50618/2014 and IEC 62930/2017 | Dynamic CablesSolar DC CableSingle core photovoltaic cable, EN 50618 / IS 17293:2020 / IEC 62930 | Finolex CablesSolar Endura PV CablesSingle-conductor tinned copper PV string cable, electron-beam cross-linked | KEI IndustriesCables for Photovoltaics (Solar Cables) | KEI IndustriesPV Solar Cables | LAPP IndiaÖLFLEX SOLAR XLR-I5 | Polycab IndiaPolycab Solar AS NZS 5000 PVCPhotovoltaic power cable, flame retardant | Polycab IndiaPolycab Solar AS NZS 5000 PVC-ATPhotovoltaic power cable, flame retardant, anti termite | Polycab IndiaPolycab Solar AS NZS 5000 PVC-TwistPhotovoltaic power cable, flame retardant, two single cores twisted | Polycab IndiaPolycab Solar AS NZS 5000 PVC-Twist ATPhotovoltaic power cable, flame retardant, two single cores twisted, anti termite | Polycab IndiaPolycab Solar AS NZS 5000 RFHPhotovoltaic power cable, halogen free, reduced fire hazard | Polycab IndiaPolycab Solar AS NZS 5000 RFH-ATPhotovoltaic power cable, halogen free, reduced fire hazard, anti termite | Polycab IndiaPolycab Solar AS NZS 5000 RFH-TwistPhotovoltaic power cable, halogen free, reduced fire hazard, two single cores twisted | Polycab IndiaPolycab Solar AS NZS 5000 RFH-Twist ATPhotovoltaic power cable, halogen free, reduced fire hazard, two single cores twisted, anti termite | Polycab IndiaPolycab Solar AS NZS 5000 XLPOPhotovoltaic power cable, halogen free, flame retardant | Polycab IndiaPolycab Solar AS NZS 5000 XLPO-ATPhotovoltaic power cable, halogen free, flame retardant, anti termite | Polycab IndiaPolycab Solar AS NZS 5000 XLPO-TwistPhotovoltaic power cable, halogen free, flame retardant, two single cores twisted | Polycab IndiaPolycab Solar AS NZS 5000 XLPO-Twist ATPhotovoltaic power cable, halogen free, flame retardant, two single cores twisted, anti termite | Polycab IndiaPolycab Solar H1Z2Z2-K BSEN 50618Photovoltaic power cable, halogen free, flame retardant | Polycab IndiaPolycab Solar H1Z2Z2-K BSEN 50618-ATPhotovoltaic power cable, halogen free, flame retardant, anti termite | RR KabelSolar Cable – EN 50618 | RR KabelSolar Cable – IS 17293 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| General | ||||||||||||||||||||||
| Type | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC | Solar DC |
| Construction | ||||||||||||||||||||||
| Conductor | Tinned copper | NA | Tinned copper | Tinned copper | Tinned copper | NA | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Tinned copper | Tinned copper | Tinned copper | Tinned copper |
| Cross-section | 2.5–300 mm² | 1.5–400 mm² | 1.5–400 mm² | 1.5–240 mm² | 1.5–240 mm² | 1.5–300 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 120–630 mm² | 2.5–240 mm² | 2.5–240 mm² | 1.5–240 mm² | 1.5–400 mm² |
| Printed cross-sections | 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm² | 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm² | 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm² | 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm² | 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm² | 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 120, 150, 185, 240, 300, 400, 500, 630 mm² | 2.5, 4.0, 6.0, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm² | 2.5, 4.0, 6.0, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm² | 1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 185.0, 240.0 mm² | 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm² |
| Cores | Single core | Single core | Single-conductor | NA | Single core | 1 | 1 | 1 | 2 | 2 | 1 | 1 | 2 | 2 | 1 | 1 | 2 | 2 | Single core | Single core | NA | NA |
| Insulation | XLPO (electron beam cross-linked polyolefin co-polymer) | Halogen-free cross-linked polyolefin (XLPO), electron beam cross-linked | Electron Beam Cross-Linked Halogen-free & Flame Retardant Compound (XLPO) | Cross linked halogen-free polyolefin | Crosslinked halogen free & flame retardant | Electron beam cross-linked polymer compound | cross linked halogen free flame retardant material | cross linked halogen free flame retardant material | cross linked halogen free flame retardant material | cross linked halogen free flame retardant material | cross linked halogen free flame retardant material | cross linked halogen free flame retardant material | cross linked halogen free flame retardant material | cross linked halogen free flame retardant material | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | UV resistant, cross linkable, halogen free, flame retardant compound | UV resistant crosslinked halogen free flame retardant |
| Sheath | XLPO (electron beam cross-linked polyolefin co-polymer) | Halogen-free XLPO, UV resistant | Electron Beam Cross-Linked Halogen-free & Flame Retardant Compound | Cross linked halogen-free polyolefin | Crosslinked halogen free & flame retardant UV and ozone resistant | NA | Polyvinyl Chloride | Polyvinyl Chloride | Polyvinyl Chloride | Polyvinyl Chloride | Reduced Fire Hazard Material | Reduced Fire Hazard Material | Reduced Fire Hazard Material | Reduced Fire Hazard Material | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | E-Beam cross linked halogen free and flame-retardant compound (XLPO) | UV resistant, cross linkable, halogen free, flame retardant compound | UV resistant crosslinked halogen free flame retardant |
| Armoured | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA |
| Conductor class | Class 5 | Class 5 (EN 50618 range, tinned copper); IS 17293 range Class 5 tinned or bare copper, Class 2 copper or aluminium from 16 mm² | Class 5 | Class 5 | Class 5 | NA | Class 2 | Class 2 | Class 2 | Class 2 | Class 2 | Class 2 | Class 2 | Class 2 | Class 2 | Class 2 | Class 2 | Class 2 | Class 5 | Class 5 | Class 5 | NA |
| Min bending radius | > 4 x cable OD | 4 x overall diameter (fixed installation, EN 50618 column) | 4x cable diameter (<= 8 mm); 5x cable diameter (8-12 mm); 6x cable diameter (> 12 mm) | 4 times the diameter | 6 x OD (fixed), 15 x OD (occasional flexing) | NA | Fixed installation > 15D; occasionally moved > 18D | Fixed installation > 15D; occasionally moved > 18D | Fixed installation > 15D; occasionally moved > 18D | Fixed installation > 15D; occasionally moved > 18D | Fixed installation > 15D; occasionally moved > 25D | Fixed installation > 15D; occasionally moved > 25D | Fixed installation > 15D; occasionally moved > 25D | Fixed installation > 15D; occasionally moved > 25D | Fixed installation > 6D; occasionally moved > 8D | Fixed installation > 15D; occasionally moved > 25D | Fixed installation > 6D | Fixed installation > 15D; occasionally moved > 25D | Fixed installation > 6D; occasionally moved > 8D | Fixed installation > 15D; occasionally moved > 25D | Fixed installation approx. 4 x cable Ø | Fixed installation approx. 4 x cable Ø |
| Electrical | ||||||||||||||||||||||
| Voltage rating | 1.5 kV | 1.0/1.0 kV AC; 1.5 kV DC | 1.0/1.0 kV AC; 1.5 kV DC | 0.6/1.0 kV | 1.5 kV DC | NA | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | 1500 V DC | AC 0.6/1.0 kV | AC 1.0/1.0 kV |
| Fire performance | Flame retardant (EN 60332-1-2); smoke emission (EN 61034-2); halogen free (EN 50525-1) | Flame retardant; low smoke; halogen free | Flame non propagation; fire non-propagation; low smoke halogen-free; low corrosive gas emission; low smoke emission | Halogen-free: low smoke emission and low toxicity during fire; flame & fire retardant | Flame retardant; low smoke emission; halogen-free | halogen-free | Flame retardant | Flame retardant | Flame retardant | Flame retardant | Halogen free; Reduced fire hazard | Halogen free; Reduced fire hazard | Halogen free; Reduced fire hazard | Halogen free; Reduced fire hazard | Halogen free; Flame retardant | Halogen free; Flame retardant | Halogen free; Flame retardant | Halogen free; Flame retardant | Halogen free; Flame retardant | Halogen free; Flame retardant | Flame retardant; low smoke; halogen free | Flame retardant; halogen free |
| Operating temperature | -40–120 °C | -40–90 °C | -40–90 °C | -40–90 °C | -40–90 °C | NA | -20–90 °C | -20–90 °C | -20–90 °C | -20–90 °C | -40–90 °C | -40–90 °C | -20–90 °C | -40–90 °C | -40–120 °C | -40–120 °C | -40–120 °C | -40–120 °C | -40–120 °C | -40–120 °C | -40–90 °C | -40–90 °C |
| UV resistant | Yes | Yes | Yes | Yes | Yes | NA | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Max permissible voltage | 1.8 kV | 1.8 kV DC | 1.5 kV DC | 2000 Vdc | 1.8 kV DC | NA | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 1800 V | 0.9/1.8 kV DC | 0.9/1.8 kV DC |
| Test voltage | 6.5 kV 50 Hz AC or 15 kV DC for 5 min | NA | 6.5 kV | NA | 6.5 kV AC; 15 kV DC | NA | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | 6.5 kV AC 50Hz | NA | AC 6.5 kV / DC 15 kV (15 min.) | NA |
| Max conductor temperature | NA | 120 °C | 120 °C | 120 °C | 120 °C | NA | 90 °C | 90 °C | 90 °C | 90 °C | 90 °C | 90 °C | 90 °C | 90 °C | 120 °C | 120 °C | 120 °C | 120 °C | 120 °C | 120 °C | 120 °C | NA |
| Ozone resistant | Yes | Yes | Yes | Yes | Yes | NA | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Chemical resistance | NA | Mineral oil, acid, alkali, ammonia | Excellent (chemical and oil; grease and mineral oil) | Mineral oil, ammonia, acidic and alkaline resistance; very good resistance to oil and chemicals | Mineral oil, acid and alkaline; very good resistance to oil and chemicals | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | Mineral oil, acid, alkali and ammonia resistant | Acid and alkali resistant; ammonia resistant |
| Expected service life | 25 years | 25 years | 25 years | 30 years | 30 years | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA |
| Certification | ||||||||||||||||||||||
| Standards | EN 50618, IEC 62930 | EN 50618, IS 17293, IEC 62930 | EN 50618, IEC 62930, IS 17293 | 2Pfg 1169/08.2007, BSEN 50618 | 2 Pfg 1169/08.2007, EN 50618 | NA | AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228 | AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228 | AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228 | AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228 | AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228 | AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228 | AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228 | AS/NZS 5000.1, AS/NZS 3808, EN 50618, IEC 60228 | AS/NZS 5000.1, IEC 62930, UL 4703, EN 50618, IEC 60228 | AS/NZS 5000.1, IEC 62930, UL 4703, EN 50618, IEC 60228, AS/NZS 3808 | AS/NZS 5000.1, IEC 62930, UL 4703, EN 50618, IEC 60228, AS/NZS 3808 | AS/NZS 5000.1, IEC 62930, UL 4703, EN 50618, IEC 60228, AS/NZS 3808 | EN 50618, IEC 62930, UL 4703, IEC 60228 | EN 50618, IEC 62930, UL 4703, IEC 60228 | EN 50618 | IS 17293, IEC 62930 |
| Certifications | TUV | BIS / ISI Mark IS 17293, CE / CPR DoP | TÜV Rheinland | TÜV, VDE, UTE, IMQ | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA |
| Source | ||||||||||||||||||||||
| Model code | H1Z2Z2-K | H1Z2Z2-K | H1Z2Z2-K | PV1-F | PV-F; H1Z2Z2-K | 820104000201 (1x1.5 BK), 820104000202 (1x2.5 BK) | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA | NA |
| Datasheet | Datasheet (PDF) of APAR Industries E-Beam irradiated ATC / XLPO solar cable (opens the maker's site) | Datasheet (PDF) of Dynamic Cables Solar DC Cable (opens the maker's site) | Datasheet (PDF) of Finolex Cables Solar Endura PV Cables (opens the maker's site) | Datasheet (PDF) of KEI Industries Cables for Photovoltaics (Solar Cables) (opens the maker's site) | Spec page of KEI Industries PV Solar Cables (opens the maker's site) | Spec page of LAPP India ÖLFLEX SOLAR XLR-I5 (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 PVC (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 PVC-AT (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 PVC-Twist (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 PVC-Twist AT (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 RFH (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 RFH-AT (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 RFH-Twist (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 RFH-Twist AT (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 XLPO (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 XLPO-AT (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 XLPO-Twist (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar AS NZS 5000 XLPO-Twist AT (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618 (opens the maker's site) | Datasheet (PDF) of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618-AT (opens the maker's site) | Spec page of RR Kabel Solar Cable – EN 50618 (opens the maker's site) | Spec page of RR Kabel Solar Cable – IS 17293 (opens the maker's site) |
| CheckedFigures compared with the maker's sheet | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 |
| Details | Details of APAR Industries E-Beam irradiated ATC / XLPO solar cable | Details of Dynamic Cables Solar DC Cable | Details of Finolex Cables Solar Endura PV Cables | Details of KEI Industries Cables for Photovoltaics (Solar Cables) | Details of KEI Industries PV Solar Cables | Details of LAPP India ÖLFLEX SOLAR XLR-I5 | Details of Polycab India Polycab Solar AS NZS 5000 PVC | Details of Polycab India Polycab Solar AS NZS 5000 PVC-AT | Details of Polycab India Polycab Solar AS NZS 5000 PVC-Twist | Details of Polycab India Polycab Solar AS NZS 5000 PVC-Twist AT | Details of Polycab India Polycab Solar AS NZS 5000 RFH | Details of Polycab India Polycab Solar AS NZS 5000 RFH-AT | Details of Polycab India Polycab Solar AS NZS 5000 RFH-Twist | Details of Polycab India Polycab Solar AS NZS 5000 RFH-Twist AT | Details of Polycab India Polycab Solar AS NZS 5000 XLPO | Details of Polycab India Polycab Solar AS NZS 5000 XLPO-AT | Details of Polycab India Polycab Solar AS NZS 5000 XLPO-Twist | Details of Polycab India Polycab Solar AS NZS 5000 XLPO-Twist AT | Details of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618 | Details of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618-AT | Details of RR Kabel Solar Cable – EN 50618 | Details of RR Kabel Solar Cable – IS 17293 |
Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Sizes are the cross-sections each maker prints for a range, so one product covers many sizes; per-size values such as current rating are on the datasheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.
What differs between them
Counted from the 22 products above, as printed.
- Type: Solar DC on all 22
- Conductor: 12 Aluminium, 8 Tinned copper; 2 not published
- Cross-section: 1.5 to 630 mm² as printed (ranges included)
- Cores: 19 of 22 publish it; values in the table
- Voltage rating: 21 of 22 publish it; values in the table
- Insulation: 22 of 22 publish it; values in the table
- Sheath: 21 of 22 publish it; values in the table
- Standards: 21 of 22 publish a list; EN 50618 on 19, IEC 60228 on 14, AS/NZS 5000.1 on 12, AS/NZS 3808 on 11
- Fire performance: 22 of 22 publish it; values in the table
- Operating temperature: -40 to 120 °C as printed (ranges included); 1 not published
- UV resistant: 21 of 22; 1 not published
- Max permissible voltage: 1800 V on 14, 0.9/1.8 kV DC on 2, 1.8 kV DC on 2, 1.5 kV DC on 1, 1.8 kV on 1, 2000 Vdc on 1; 1 not published
- Test voltage: 17 of 22 publish it; values in the table
- Max conductor temperature: 90 to 120 °C as printed; 3 not published
- Conductor class: 20 of 22 publish it; values in the table
- Min bending radius: 21 of 22 publish it; values in the table
- Ozone resistant: 21 of 22; 1 not published
- Chemical resistance: 6 of 22 publish it; values in the table
- Certifications: 4 of 22 publish a list
- Expected service life: 25 to 30 years as printed; 17 not published
Nearby cross-section values
A page needs 3+ products from 3+ companies; values without one are in the full list by cross-section.
Questions about 240 mm² solar DC cables
- Which companies make 240 mm² solar DC cables in India?
- 7 companies list 22 products at this size: APAR Industries (E-Beam irradiated ATC / XLPO solar cable); Dynamic Cables (Solar DC Cable); Finolex Cables (Solar Endura PV Cables); KEI Industries (Cables for Photovoltaics (Solar Cables), PV Solar Cables); LAPP India (ÖLFLEX SOLAR XLR-I5); Polycab India (Polycab Solar AS NZS 5000 PVC, Polycab Solar AS NZS 5000 PVC-AT, Polycab Solar AS NZS 5000 PVC-Twist, Polycab Solar AS NZS 5000 PVC-Twist AT, Polycab Solar AS NZS 5000 RFH, Polycab Solar AS NZS 5000 RFH-AT, Polycab Solar AS NZS 5000 RFH-Twist, Polycab Solar AS NZS 5000 RFH-Twist AT, Polycab Solar AS NZS 5000 XLPO, Polycab Solar AS NZS 5000 XLPO-AT, Polycab Solar AS NZS 5000 XLPO-Twist, Polycab Solar AS NZS 5000 XLPO-Twist AT, Polycab Solar H1Z2Z2-K BSEN 50618, Polycab Solar H1Z2Z2-K BSEN 50618-AT); RR Kabel (Solar Cable – EN 50618, Solar Cable – IS 17293). They are listed A–Z by company, not ranked.
- How do these 240 mm² solar DC cables differ?
- Type: Solar DC on all 22. Conductor: 12 Aluminium, 8 Tinned copper; 2 not published. Cross-section: 1.5 to 630 mm² as printed (ranges included). Cores: 19 of 22 publish it; values in the table. Counted from the 22 products as each maker prints them.
- Where do these figures come from?
- From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 240 mm² are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.
Is your company on this list? Add it, update your details or raise a concern →