70 mm² solar DC cables in India

11 products from 8 companies, side by side. All 129 products in Solar and power cables · Listed A–Z, not ranked · Reviewed November 2026

70 mm² DC cable carries large combined currents in utility-scale plants. Copper and aluminium both appear; compare the voltage rating, the standard and whether the cable suits direct burial.

70 mm² compared

A–Z by company, not ranked · NA: not published by the maker

FieldAPAR IndustriesE-Beam irradiated ATC / XLPO solar cableSolar DC cable, electron beam cross-linked, as per BS EN 50618/2014 and IEC 62930/2017Dynamic CablesSolar DC CableSingle core photovoltaic cable, EN 50618 / IS 17293:2020 / IEC 62930Finolex CablesSolar Endura PV CablesSingle-conductor tinned copper PV string cable, electron-beam cross-linkedKEI IndustriesCables for Photovoltaics (Solar Cables)KEI IndustriesPV Solar CablesLAPP IndiaÖLFLEX SOLAR XLR-I5Polycab IndiaPolycab Solar H1Z2Z2-K BSEN 50618Photovoltaic power cable, halogen free, flame retardantPolycab IndiaPolycab Solar H1Z2Z2-K BSEN 50618-ATPhotovoltaic power cable, halogen free, flame retardant, anti termiteRolliflex CablesSolar CablesRR KabelSolar Cable – EN 50618RR KabelSolar Cable – IS 17293
General
Type Solar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DCSolar DC
Construction
Conductor Tinned copperNATinned copperTinned copperTinned copperNATinned copperTinned copperTinned copperTinned copperTinned copper
Cross-section 2.5–300 mm²1.5–400 mm²1.5–400 mm²1.5–240 mm²1.5–240 mm²1.5–300 mm²2.5–240 mm²2.5–240 mm²1.5–120 mm²1.5–240 mm²1.5–400 mm²
Printed cross-sections 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm²2.5, 4.0, 6.0, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm²2.5, 4.0, 6.0, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240 mm²1.50, 2.50, 4.00, 6.00, 10.00, 16.00, 25.00, 35.00, 50.00, 70.00, 95.00, 120.00 mm²1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 185.0, 240.0 mm²1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²
Cores Single coreSingle coreSingle-conductorNASingle core1Single coreSingle coreNANANA
Insulation XLPO (electron beam cross-linked polyolefin co-polymer)Halogen-free cross-linked polyolefin (XLPO), electron beam cross-linkedElectron Beam Cross-Linked Halogen-free & Flame Retardant Compound (XLPO)Cross linked halogen-free polyolefinCrosslinked halogen free & flame retardantElectron beam cross-linked polymer compoundE-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)Halogen free cross linked XLPO (LSZH XL) compoundUV resistant, cross linkable, halogen free, flame retardant compoundUV resistant crosslinked halogen free flame retardant
Sheath XLPO (electron beam cross-linked polyolefin co-polymer)Halogen-free XLPO, UV resistantElectron Beam Cross-Linked Halogen-free & Flame Retardant CompoundCross linked halogen-free polyolefinCrosslinked halogen free & flame retardant UV and ozone resistantNAE-Beam cross linked halogen free and flame-retardant compound (XLPO)E-Beam cross linked halogen free and flame-retardant compound (XLPO)Halogen free cross linked XLPO compound in Black or Black/Red colourUV resistant, cross linkable, halogen free, flame retardant compoundUV resistant crosslinked halogen free flame retardant
Armoured NANANANANANANANANANANA
Conductor class Class 5Class 5 (EN 50618 range, tinned copper); IS 17293 range Class 5 tinned or bare copper, Class 2 copper or aluminium from 16 mm²Class 5Class 5Class 5NAClass 5Class 5Class 5 (EN/IEC 60228)Class 5NA
Min bending radius > 4 x cable OD4 x overall diameter (fixed installation, EN 50618 column)4x cable diameter (<= 8 mm); 5x cable diameter (8-12 mm); 6x cable diameter (> 12 mm)4 times the diameter6 x OD (fixed), 15 x OD (occasional flexing)NAFixed installation > 6D; occasionally moved > 8DFixed installation > 15D; occasionally moved > 25DNAFixed installation approx. 4 x cable ØFixed installation approx. 4 x cable Ø
Electrical
Voltage rating 1.5 kV1.0/1.0 kV AC; 1.5 kV DC1.0/1.0 kV AC; 1.5 kV DC0.6/1.0 kV1.5 kV DCNA1500 V DC1500 V DCNAAC 0.6/1.0 kVAC 1.0/1.0 kV
Fire performance Flame retardant (EN 60332-1-2); smoke emission (EN 61034-2); halogen free (EN 50525-1)Flame retardant; low smoke; halogen freeFlame non propagation; fire non-propagation; low smoke halogen-free; low corrosive gas emission; low smoke emissionHalogen-free: low smoke emission and low toxicity during fire; flame & fire retardantFlame retardant; low smoke emission; halogen-freehalogen-freeHalogen free; Flame retardantHalogen free; Flame retardantNAFlame retardant; low smoke; halogen freeFlame retardant; halogen free
Operating temperature -40–120 °C-40–90 °C-40–90 °C-40–90 °C-40–90 °CNA-40–120 °C-40–120 °CNA-40–90 °C-40–90 °C
UV resistant YesYesYesYesYesNAYesYesNAYesYes
Max permissible voltage 1.8 kV1.8 kV DC1.5 kV DC2000 Vdc1.8 kV DCNA1800 V1800 VNA0.9/1.8 kV DC0.9/1.8 kV DC
Test voltage 6.5 kV 50 Hz AC or 15 kV DC for 5 minNA6.5 kVNA6.5 kV AC; 15 kV DCNA6.5 kV AC 50HzNANAAC 6.5 kV / DC 15 kV (15 min.)NA
Max conductor temperature NA120 °C120 °C120 °C120 °CNA120 °C120 °C120 °C120 °CNA
Ozone resistant YesYesYesYesYesNAYesYesNAYesYes
Chemical resistance NAMineral oil, acid, alkali, ammoniaExcellent (chemical and oil; grease and mineral oil)Mineral oil, ammonia, acidic and alkaline resistance; very good resistance to oil and chemicalsMineral oil, acid and alkaline; very good resistance to oil and chemicalsNANANANAMineral oil, acid, alkali and ammonia resistantAcid and alkali resistant; ammonia resistant
Expected service life 25 years25 years25 years30 years30 yearsNANANANANANA
Certification
Standards EN 50618, IEC 62930EN 50618, IS 17293, IEC 62930EN 50618, IEC 62930, IS 172932Pfg 1169/08.2007, BSEN 506182 Pfg 1169/08.2007, EN 50618NAEN 50618, IEC 62930, UL 4703, IEC 60228EN 50618, IEC 62930, UL 4703, IEC 60228EN 50618, TÜV2PFG1169/08.2007EN 50618IS 17293, IEC 62930
Certifications TUVBIS / ISI Mark IS 17293, CE / CPR DoPTÜV RheinlandTÜV, VDE, UTE, IMQNANANANANANANA
Source
Model codeH1Z2Z2-KH1Z2Z2-KH1Z2Z2-KPV1-FPV-F; H1Z2Z2-K820104000201 (1x1.5 BK), 820104000202 (1x2.5 BK)NANAH1Z2Z2-KNANA
DatasheetDatasheet (PDF) of APAR Industries E-Beam irradiated ATC / XLPO solar cable (opens the maker's site)Datasheet (PDF) of Dynamic Cables Solar DC Cable (opens the maker's site)Datasheet (PDF) of Finolex Cables Solar Endura PV Cables (opens the maker's site)Datasheet (PDF) of KEI Industries Cables for Photovoltaics (Solar Cables) (opens the maker's site)Spec page of KEI Industries PV Solar Cables (opens the maker's site)Spec page of LAPP India ÖLFLEX SOLAR XLR-I5 (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618 (opens the maker's site)Datasheet (PDF) of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618-AT (opens the maker's site)Spec page of Rolliflex Cables Solar Cables (opens the maker's site)Spec page of RR Kabel Solar Cable – EN 50618 (opens the maker's site)Spec page of RR Kabel Solar Cable – IS 17293 (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026
DetailsDetails of APAR Industries E-Beam irradiated ATC / XLPO solar cableDetails of Dynamic Cables Solar DC CableDetails of Finolex Cables Solar Endura PV CablesDetails of KEI Industries Cables for Photovoltaics (Solar Cables)Details of KEI Industries PV Solar CablesDetails of LAPP India ÖLFLEX SOLAR XLR-I5Details of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618Details of Polycab India Polycab Solar H1Z2Z2-K BSEN 50618-ATDetails of Rolliflex Cables Solar CablesDetails of RR Kabel Solar Cable – EN 50618Details of RR Kabel Solar Cable – IS 17293

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Sizes are the cross-sections each maker prints for a range, so one product covers many sizes; per-size values such as current rating are on the datasheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 11 products above, as printed.

  • Type: Solar DC on all 11
  • Conductor: Tinned copper; 9 of 11 publish it
  • Cross-section: 1.5 to 400 mm² as printed (ranges included)
  • Cores: 7 of 11 publish it; values in the table
  • Voltage rating: 9 of 11 publish it; values in the table
  • Insulation: 11 of 11 publish it; values in the table
  • Sheath: 10 of 11 publish it; values in the table
  • Standards: 10 of 11 publish a list; EN 50618 on 8, IEC 62930 on 6, IS 17293 on 3, IEC 60228 on 2
  • Fire performance: 10 of 11 publish it; values in the table
  • Operating temperature: -40 to 120 °C as printed (ranges included); 2 not published
  • UV resistant: 9 of 11; 2 not published
  • Max permissible voltage: 0.9/1.8 kV DC on 2, 1.8 kV DC on 2, 1800 V on 2, 1.5 kV DC on 1, 1.8 kV on 1, 2000 Vdc on 1; 2 not published
  • Test voltage: 5 of 11 publish it; values in the table
  • Max conductor temperature: 120 °C; 8 of 11 publish it
  • Conductor class: 9 of 11 publish it; values in the table
  • Min bending radius: 9 of 11 publish it; values in the table
  • Ozone resistant: 9 of 11; 2 not published
  • Chemical resistance: 6 of 11 publish it; values in the table
  • Certifications: 4 of 11 publish a list
  • Expected service life: 25 to 30 years as printed; 6 not published

Questions about 70 mm² solar DC cables

Which companies make 70 mm² solar DC cables in India?
8 companies list 11 products at this size: APAR Industries (E-Beam irradiated ATC / XLPO solar cable); Dynamic Cables (Solar DC Cable); Finolex Cables (Solar Endura PV Cables); KEI Industries (Cables for Photovoltaics (Solar Cables), PV Solar Cables); LAPP India (ÖLFLEX SOLAR XLR-I5); Polycab India (Polycab Solar H1Z2Z2-K BSEN 50618, Polycab Solar H1Z2Z2-K BSEN 50618-AT); Rolliflex Cables (Solar Cables); RR Kabel (Solar Cable – EN 50618, Solar Cable – IS 17293). They are listed A–Z by company, not ranked.
How do these 70 mm² solar DC cables differ?
Type: Solar DC on all 11. Conductor: Tinned copper; 9 of 11 publish it. Cross-section: 1.5 to 400 mm² as printed (ranges included). Cores: 7 of 11 publish it; values in the table. Counted from the 11 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 70 mm² are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.