Tobor MTX Standard 30

Listed A–Z, not ranked · Reviewed November 2026

As printed in the spec page, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.

Rating

Rated energy
NA
Rated power
30 kW
Charge/discharge rate
NA
Duration
NA
PCS included
Yes
Cooling
Air

Battery

Cell capacity
100 Ah
Chemistry
LFP
DC voltage range
150–1000 V
Cycle life
6000 cycles

Electrical

AC voltage
NA
AC frequency
NA
Round-trip efficiency
NA
Efficiency measured
NA

Physical

Size (mm)
1654 × 1000 × 1856 mm (axes not stated)
Weight
NA
Enclosure rating
NA

Environment

Operating temperature
-40–70 °C
Max altitude
NA
Noise at 1 m
NA

Safety

Fire suppression
NA
Certifications
NA
Model code:
MTX-S30
Checked:
November 2026, against the spec page

Full datasheet

Every row the maker prints, copied as written, read 2026-11-15.

Overview

Model
MTX-S30MTX Standard 30
Product line
Commercial & Industrial · 30 kW – 2 MW
Description
Entry point to TOBOR commercial storage: one 30 kW bidirectional, isolated power module in the two-bay MTX cabinet. Built for peak management and load shifting at small factories, clinics, restaurants and offices, with automatic battery restart for loads that tolerate a short interruption.

Battery

Cell type
LiFePO4 (LFP)
Cell
3.2 V · 100 AhGrade-A 3.2 V LFP — 100 Ah cells for 30–250 kW systems, 314 Ah cells for 250 kW–2 MW PTX and CTX containers. Capacity- and IR-matched per pack.(tobor.in)320 Wh · 1.0 kWh(tobor.in)
Rated energy
Sized to required backup durationSized to runtime(tobor.in)
Cycle life
~6,000 cycles*
Cooling
Forced air

Power and grid

Rated AC power
30 kW30 kW30 kW · 1 PM
PCS
30 kW bidirectional, high-frequency isolatedBidirectional power modules — 30 kW in MTX cabinets (with solar MPPT on MTX Hybrid), 125 kW PMs at 98.5% peak efficiency in PTX and CTX. Grid-tied, off-grid and island modes.(tobor.in)
PCS DC voltage range
150–1000 V (full power 300–1000 V)
AC voltage range
3φ 260–530 V260–530 V · 3-phase + PE
PCS efficiency
≥ 95.5%≥ 95.5%
Power factor
≥ 0.99
Units in parallel
Up to 8 PMs off-grid · 60 PMs grid-tied
On/off-grid switching
~30–40 sAutomatic restart in ~30–40 sMTX Standard cabinets restart automatically on battery in about 30–40 seconds, for loads that tolerate a short break.(tobor.in)

Solar and generator

Works with
Grid · Solar PV · DG · EV charging

Environment

Operating temperature
-40 °C → +70 °C (full rating to +55 °C)

Physical

Reference size (series)
1,654 × 1,000 × 1,856 mm
Form factor
Commercial cabinet · 1 × 30 kW PMTwo-bay cabinet · battery bay + equipment bay
Installation
MTX cabinets (about 1.65 × 1.0 m) are floor-standing — typically inside a utility room next to the existing DG room.(tobor.in)
Installation time
MTX cabinets (30–60 kW) and PTX systems up to 250 kW take 2–4 days on site, depending on civil work and existing wiring.(tobor.in)

Communication

Communication
CAN
Remote monitoring
Cloud EMS dashboard · remote diagnostics
BMS / EMS
In-house TOBOR BMSIn-house TOBOR EMS

Features

Application
Small MSME · clinic · retail · 30 kVA DG replacementPeak shaving · ToU shifting · Solar self-use · Backup reserve

More BESS cabinets from Tobor

Tobor MTX Standard 30, in short

The Tobor MTX Standard 30 is a cabinet BESS, with rated power 30 kW, cooling Air and PCS included. Tobor has 2 other cabinet BESS on this site.

Questions about the Tobor MTX Standard 30

What are the main specifications of the Tobor MTX Standard 30?
Rated power 30 kW; Cooling Air; PCS included. As printed on Tobor's spec page (checked November 2026); the full list is on this page.
Where can I find the Tobor MTX Standard 30 spec page?
Tobor publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
Who makes the Tobor MTX Standard 30?
Tobor, with its head office in Gurugram. It has 3 cabinet BESS on this site, including this one.

Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.

Values as Tobor prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Tobor. Product and company names are trademarks of their owners, used only to identify the product.

Not sure what to buy? Ask us what's compatible and what size fits your site.