8 products from 7 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026
400 kVA sets back up large factories, hospitals, data centres and malls. They are three-phase sets with large six-cylinder engines; compare fuel consumption, governing and the enclosure size and weight.
400 kVA compared
A–Z by company, not ranked · NA: not published by the maker
| Field | Cummins IndiaQSM15 Series380 - 500 kVA, 304 - 400 kWe Prime | Genlite EngineeringSterling Green SGB PR-IVBaudouin-engined diesel gensets, 320 to 750 kVA | Jakson GroupJSP-IVSilent diesel generating sets, radiator cooled, 7.5 to 750 kVA | Kirloskar Oil EnginesKG4-400WS11400 kVA Diesel Generator | Kirloskar Oil EnginesOptiprime 400 kVA400 kVA Optiprime | Mahindra PowerolM10DR to M650DRAcoustic DG sets, 10 to 650 kVA | Ojus Power and Technologies400 kVADiesel genset model | Sudhir PowerCS D5P seriesCummins-powered silent diesel gensets (2023 brochure) |
|---|---|---|---|---|---|---|---|---|
| Output | ||||||||
| Rating | 380–500 kVA | 320–750 kVA | 7.5–750 kVA | 400 kVA | 400 kVA | 10–650 kVA | 400 kVA | 7.5–2250 kVA |
| Power output | from 304 kWe | 256–600 kWe | 6–600 kWe | 320 kWe | 320 kWe | 8–520 kWe | NA | NA |
| Printed ratings | 380, 400, 500 kVA | 320, 400, 450, 500, 650, 750 kVA | 7.5, 10, 15, 18.5, 20, 25, 27.5, 30, 35, 40, 41, 50, 58.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 320, 380, 400, 500, 650, 750 kVA | 400 kVA | 400 kVA | 10, 15, 20, 25, 30, 35, 40, 45, 50, 58.5, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 400, 500, 525, 650 kVA | NA | 7.5, 10, 15, 20, 25, 30, 35, 40, 50, 62.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 275, 300, 320, 380, 400, 500, 600, 625, 650, 750, 810, 910, 1010, 1250, 1500, 1800, 2000, 2250 kVA |
| Rating basis | Prime | NA | NA | Prime | Prime | NA | Prime | Prime |
| Output voltage | 415 | 415 | NA | 415 (3ɸ) | 415 (3ɸ) | 230/415 (10 to 40 kVA), 415 (3 phase) above | 415 | NA |
| Frequency | 50 Hz | 50 Hz | NA | 50 Hz | 50 Hz | 50 Hz | 50 Hz | NA |
| Power factor | 0.8 (lagging) | 0.8 | NA | 0.8 | 0.8 | 0.8 lagging | 0.8 | NA |
| Phase | 3-phase | NA | 1-phase, 3-phase | 3-phase | 3-phase | 1-phase, 3-phase | 3-phase | NA |
| Build | ||||||||
| Fuel | Diesel | Diesel | Diesel | Diesel | Diesel | NA | Diesel | NA |
| Engine | Cummins QSM15-G1 | Baudouin 6M21G0D4/5 to 6M33G4D4/5 | X2.5-G5 to QSK19-G30 (and others) | DV8ETA 4G2 | 6K1080ETA 4G2 | Mahindra M2155G1 and others; Perkins 2806FA-E18TAG1 and 2806FA-E18TAG2 for 400 to 650 kVA | Baudouin 6M21G2D4/5 | X1.3TAA-G1, X1.3TAA-G7 |
| Alternator | STAMFORD HCI444E, HCI444F and HCI544D | Leroy Somer and Stamford make, brushless, self excited, IP 23, class H/H insulation, single bearing | NA | NA | NA | CG/LS/Equivalent | Stamford HCI444F | NA |
| Enclosure | Acoustic | NA | Acoustic | Acoustic | Acoustic | Acoustic | NA | Acoustic |
| Dimensions (L × W × H) | 5300 × 1900 × 2490 mm (axes not stated) | 7200 × 2200 × 3395 mm (axes not stated) | 6800 × 2050 × 2860 mm (axes not stated) | 5575 × 2125 × 2610 mm (axes not stated) | 7500 × 1450 × 1900 mm (axes not stated) | 5800 × 2200 × 2300 mm (axes not stated) | 5700 × 2100 × 3113 mm (axes not stated) | 10450 × 3500 × 3800 mm (axes not stated) |
| Fuel tank capacity | 715 to 745 | 900 to 990 | 85 to 980 | NA | NA | 55 to 800 | 900 | NA |
| Weight | about 5515–5915 kg | about 6480–8800 kg | about 772–10156 kg | 6415 kg | 6000 kg | 690–3920 kg | 6700 kg | NA |
| Certification | ||||||||
| CPCB IV+ | Yes | Yes | Yes | Yes | Yes | NA | NA | NA |
| Certifications and standards | IS/IEC 60034-1, ISO 8528, ISO 3046, IS 1460, ISO 9001, IS 13018 | ISO, AS/NZ, IEC, IEEE, BS | NA | ISO 8528 | ISO 8528 | IS/IEC60034-1 (alternator) | ISO 8528, ISO 3046-1, ISO 15550 | NA |
| Performance | ||||||||
| Governing class | ISO 8528-5 G2 | G3 | G2/G3 | G3 | NA | G2/G3 | G3 as per ISO 8528-5 | NA |
| Fuel consumption | NA | 117 L/h at 75% load (largest set) | NA | NA | NA | NA | 61.3 L/h at 75% load | NA |
| Noise level | 75 dBA at 1 m, 75% load, free field | NA | NA | <75 dBA | <75 DBA | NA | NA | 75 dBA at 1 m |
| Controls | ||||||||
| Controller | Cummins PowerStart PS0602 | DEIF SGC 420 MK | NA | NA | NA | GC 1115 (10 to 200 kVA), GC 1116 (250 and 320 kVA), DSE7320 (400 to 650 kVA) | DEIF SGC 420 MK II | PS0600/1/2 (15-1010 kVA); PCC 3201 (1250-3750 kVA) |
| Support | ||||||||
| Warranty | 5 Yrs engine critical parts warranty | NA | 5C Warranty (5 years/ 5000 hours) | NA | 5-year standard warranty | Standard warranty of 2 Years/5000 Hours, 5 Years 5C warranty | NA | NA |
| Source | ||||||||
| Note | Sheet lists six models from 320 to 750 kVA. Higher ratings are available on request. | Dimensions, weight and day fuel tank are for the acoustic set. | ||||||
| Model code | CI 380D5P, CI 400D5P, CI 500D5P | SGB 320 PR-IV, SGB 400 PR-IV, SGB 450 PR-IV, SGB 500 PR-IV, SGB 650 PR-IV, SGB 750 PR-IV | JSP-IV 7.5 to JSP-IV 750 | NA | NA | M10DR to M650DR | NA | CS 7.5 D5P to CS 2250 D5P |
| Datasheet | Datasheet (PDF) of Cummins India QSM15 Series (opens the maker's site) | Datasheet (PDF) of Genlite Engineering Sterling Green SGB PR-IV (opens the maker's site) | Datasheet (PDF) of Jakson Group JSP-IV (opens the maker's site) | Spec page of Kirloskar Oil Engines KG4-400WS11 (opens the maker's site) | Spec page of Kirloskar Oil Engines Optiprime 400 kVA (opens the maker's site) | Datasheet (PDF) of Mahindra Powerol M10DR to M650DR (opens the maker's site) | Datasheet (PDF) of Ojus Power and Technologies 400 kVA (opens the maker's site) | Datasheet (PDF) of Sudhir Power CS D5P series (opens the maker's site) |
| CheckedFigures compared with the maker's sheet | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 | November 2026 |
| Details | Details of Cummins India QSM15 Series | Details of Genlite Engineering Sterling Green SGB PR-IV | Details of Jakson Group JSP-IV | Details of Kirloskar Oil Engines KG4-400WS11 | Details of Kirloskar Oil Engines Optiprime 400 kVA | Details of Mahindra Powerol M10DR to M650DR | Details of Ojus Power and Technologies 400 kVA | Details of Sudhir Power CS D5P series |
Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.
What differs between them
Counted from the 8 products above, as printed.
- Rating: 7.5 to 2250 kVA as printed (ranges included)
- Power output: 6 to 600 kWe as printed (ranges included); 2 not published
- Rating basis: Prime; 5 of 8 publish it
- Fuel: Diesel; 6 of 8 publish it
- CPCB IV+: 5 of 8; 3 not published
- Output voltage: 6 of 8 publish it; values in the table
- Frequency: 50 Hz; 6 of 8 publish it
- Power factor: 0.8 on 4, 0.8 (lagging) on 1, 0.8 lagging on 1; 2 not published
- Governing class: 6 of 8 publish it; values in the table
- Phase: 6 of 8 publish a list; 3-phase on 6, 1-phase on 2
- Engine: 8 of 8 publish it; values in the table
- Alternator: 4 of 8 publish it; values in the table
- Enclosure: Acoustic; 6 of 8 publish it
- Fuel consumption: 2 of 8 publish it; values in the table
- Noise level: 4 of 8 publish it; values in the table
- Controller: 5 of 8 publish it; values in the table
- Dimensions (L × W × H): 8 of 8 publish it; values in the table
- Fuel tank capacity: 55 to 800 on 1, 715 to 745 on 1, 85 to 980 on 1, 900 on 1, 900 to 990 on 1; 3 not published
- Weight: 690 to 10156 kg as printed (ranges included); 1 not published (3 printed as approximate)
- Warranty: 4 of 8 publish it; values in the table
- Certifications and standards: 6 of 8 publish a list; ISO 8528 on 4
Nearby rating values
A page needs 3+ products from 3+ companies; values without one are in the full list by rating.
Questions about 400 kVA DG sets (diesel and gas generator sets)
- Which companies make 400 kVA DG sets (diesel and gas generator sets) in India?
- 7 companies list 8 products at this size: Cummins India (QSM15 Series); Genlite Engineering (Sterling Green SGB PR-IV); Jakson Group (JSP-IV); Kirloskar Oil Engines (KG4-400WS11, Optiprime 400 kVA); Mahindra Powerol (M10DR to M650DR); Ojus Power and Technologies (400 kVA); Sudhir Power (CS D5P series). They are listed A–Z by company, not ranked.
- How do these 400 kVA DG sets (diesel and gas generator sets) differ?
- Rating: 7.5 to 2250 kVA as printed (ranges included). Power output: 6 to 600 kWe as printed (ranges included); 2 not published. Rating basis: Prime; 5 of 8 publish it. Fuel: Diesel; 6 of 8 publish it. Counted from the 8 products as each maker prints them.
- Where do these figures come from?
- From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 400 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.
Is your company on this list? Add it, update your details or raise a concern →