Listed A–Z, not ranked · Reviewed November 2026
380 - 500 kVA, 304 - 400 kWe Prime · DG sets by Cummins India
Specifications
As printed in the datasheet, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.
Output
- Rating
- 380–500 kVA
- Power output
- from 304 kWe
- Printed ratings
- 380, 400, 500 kVA
- Rating basis
- Prime
- Output voltage
- 415
- Frequency
- 50 Hz
- Power factor
- 0.8 (lagging)
- Phase
- 3-phase
Build
- Fuel
- Diesel
- Engine
- Cummins QSM15-G1
- Alternator
- STAMFORD HCI444E, HCI444F and HCI544D
- Enclosure
- Acoustic
- Dimensions (L × W × H)
- 5300 × 1900 × 2490 mm (axes not stated)
- Fuel tank capacity
- 715 to 745
- Weight
- about 5515–5915 kg
Certification
- CPCB IV+
- Yes
- Certifications and standards
- IS/IEC 60034-1, ISO 8528, ISO 3046, IS 1460, ISO 9001, IS 13018
Performance
- Governing class
- ISO 8528-5 G2
- Fuel consumption
- NA
- Noise level
- 75 dBA at 1 m, 75% load, free field
Controls
- Controller
- Cummins PowerStart PS0602
Support
- Warranty
- 5 Yrs engine critical parts warranty
- Model code:
- CI 380D5P, CI 400D5P, CI 500D5P
- Checked:
- November 2026, against the datasheet
Full datasheet
Every row the maker prints, copied as written, read 2026-11-15.
Overview
- Product
- Diesel Generator Set QSM15 Series
- Rating
- 380 - 500 kVA, 304 - 400 kWe Prime
- Badges and markings
- CPCB IV+ Emission Compliant5 YRS ENGINE CRITICAL PARTS WARRANTYCPCB IV+ Compliant; Cleaner Outside. Reliable Inside
- Sheet reference
- PSBU/CPCB IV+/QSM15/Rev-00/07 2023
Ratings
- Model
- CI 380D5P; CI 400D5P; CI 500D5P
- Duty
- Prime
- Power rating (kVA / kWe)
- CI 380D5P: 380/304; CI 400D5P: 400/320; CI 500D5P: 500/440
- Prime power definition
- Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528.
- Phases
- 3 Phase
- Output voltage and frequency (V, Hz)
- 415 V, 50 Hz
- Power factor
- 0.8
- Current (A)
- CI 380D5P: 528.6; CI 400D5P: 556.5; CI 500D5P: 695.6
- Speed (RPM)
- 1500
Engine
- Engine make
- Cummins®
- Engine model
- QSM15-G1
- Power required for rated kVA (hp)
- 594
- Cooling
- Liquid Cooled (EG Compleat 50:50)
- Aspiration
- Turbocharged, Charge Air Cooled
- Cylinders
- 6, In-line
- Bore × stroke (mm)
- 135 x 169
- Displacement (litre)
- 14.5
- Compression ratio
- 23:1
- Mean piston speed (m/s)
- 8.45
- Governor / performance class
- ISO 8528-5 G2
- Starting system
- 24 V DC Electrical
- Lube oil specification
- CK4
- Lube oil sump capacity, high–low (litre)
- 50-35
- Lubrication system capacity (litre)
- 52
- Coolant capacity (litre)
- 67
- Combustion air intake at 100% load, ±5% (cfm)
- 980
- Exhaust temperature (°C)
- 556
- Exhaust pipe size (inch)
- 6
- Engine wet weight, engine + radiator (kg)
- 1460
- Engine L × W × H (mm)
- 2400 X 1540 X 1716
- Engine features
- Cummins® QSM15 series, 6 cylinder, In-line 4 stroke, radiator cooled engineRobust and efficient air handling system with: Dry type and replaceable paper element air cleaner with restriction indicator; Optimized turbocharger for increased altitude capabilitiesOptimized fuel consumption with common rail electronic injectionSpin on single fuel filter with water separatorCooling system is designed and tested for 50°C ambient conditionsFull flow spin on lube oil filterFirst fill of lube oil and coolantElectrical starter motor with soft start engagement featureBattery charging alternator2 x 12 V DC battery
Fuel
- Fuel
- High Speed Diesel
- Standard fuel tank capacity (litre)
- CI 380D5P: 715; CI 400D5P: 715; CI 500D5P: 745
Emissions
- DEF
- AUS 32 (Premix) as per ISO 22241
- DEF tank capacity (litre)
- 87
- Exhaust aftertreatment (EATS)
- Switch Back architecture supplied by Cummins Emission SolutionsCompact design enabling optimized genset sizeIntegrated control module for engine and EATSBest in class proven technology for meeting stringent emission norms
Alternator
- Alternator make
- STAMFORD (CGT)
- Alternator frame
- CI 380D5P: HCI444E; CI 400D5P: HCI444F; CI 500D5P: HCI544D
- Alternator enclosure
- IP 23
- Voltage regulation
- ±1%
- Insulation class
- H Class
- Winding pitch
- 2/3
- Stator winding
- Double layer concentric
- Rotor
- Dynamically Balanced
- Total harmonic distortion
- No load < 1.5%, Non distorting balanced linear load < 5 %
- Maximum unbalanced load across phases
- less than or equal to 25%
- Telephone harmonic factor
- < 2%
- Alternator features
- STAMFORD HCI444E, HCI444F & HCI544D alternator frames from Cummins Generator TechnologiesBrushless type, Screen protected, Revolving field, Self-excited alternator conforming to IS/IEC 60034-1Better motor starting capabilityBest in class efficiencyCompact design with sealed bearings for longer life and lesser maintenanceImpregnation on all wound components for better mechanical strength
Controls
- Control panel
- Control panel is powder coated for weather-proof and long-lasting finish. The control panel consists of the following parts:PS0602 ControllerBus bars with suitable capacity with incoming/ outgoing terminalsIndicating lamps for 'Load ON' and 'Set Running'Instrument fuses duly wired and ferruledMCCB of suitable rating with short circuit protectionsAC/DC separation inside control panel for safety
- Engine metering
- Oil pressure, Engine temperature, Starting battery voltage, Engine running hours
- Alternator metering
- L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency. kwh, Total & per phase (kw & kVA), PF, Utility Voltage and Freq
- Engine protection
- Low lube oil pressure, High/Low coolant temperature, Battery High/Low/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level
- Alternator protection
- Over/Under Voltage, Over/Under Frequency, Loss of AC sensing. Overspeed, Over Current, kW Overload
- Data logging
- Engine hours, Control hours and upto 5 recent fault codes
- Controller features
- Cummins® PowerStart™ PS0602 control is a microprocessor based generator set monitoring, metering and control system with LCD display designed to meet the demands of today's engine driven generator setAMF FunctionalityElectronic GoverningCAN (J1939) CompatibleSync Compatible (Capable to accept external speed signal from 3rd party sync controller)Intuitive operator interface which includes LED backlit 128X64 pixel graphic display with tactile feel soft-switches & generator set status LED lampsRemote start-stopAudible & Visual warning for InducementSuitable for FAE based engine architectureConfigurable glow plug control12/24 Volt DC operationSleep modeModbus interface (RS485 RTU)In Power compatible (PC based service tool)Certifications - meets the requirement of relevant ISO, EN, Mil Std. and CE standardsMaintenance due alarm based on Engine Run Time and due dateFuel and DEF level visual displayExerciser scheduler
- Remote monitoring / telematics
- Compact & robust deviceReal time DG status & monitoring4G compatibleCompatible for 12/24 V DCReports & Notification – Alerts & WarningIsolated RS 485 interfaceDevice location using triangulation
Enclosure & acoustics
- Acoustic enclosure
- Specially designed to meet stringent MoEF/ CPCB norms of 75 dBA@1mtr at 75% load under free field conditionsThe acoustic enclosure is made CRCA sheets in Munsell green shade and a structural/sheet metal base frame painted in black11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environmentHigh quality noise absorbent and fire-retardant grade acoustic Insulation material (Rockwool) complying to IS 8183Top lifting for easy handling at customer siteExternal fuel & DEF filling provision
- Silencer
- Hospital Grade Silencer inside canopy with rain cap suitably optimized to meet stringent noise limitSilencer specifically tuned to EATS
Physical
- Length (mm)
- 5300
- Width (mm)
- 1900
- Height (mm)
- 2490
- Wet weight (kg)
- CI 380D5P: 5515; CI 400D5P: 5650; CI 500D5P: 5915
- Mounting arrangement
- Engine and alternator are mounted on a common MS fabricated base frame with AVM padsSkid mounted radiatorBase frame with integral fuel tank and DEF tank is provided with drain plug, air vent, inlet and outlet connection and provision for cleaning
Options
- Optional: engine
- Heated Architecture & HD Air cleaner
- Optional: alternator
- PMG and Space Heater
- Optional: control panel
- PCC3.3
- Optional: other
- Heated Architecture
Certifications
- Conformance standards
- IS/IEC 60034-1; ISO 1460; ISO 8528; ISO 3046; ISO 9001; ISO 13018
Features
- Highlights
- The Cummins® QSM15 series rugged engine and world class Stamford alternator powered diesel generator setProven technology with common rail electronic fuel systemExhaust after-treatment and in-cylinder solution to meet stringent emission normsSuperior finish and aestheticsCompact in size with optimum power to weight ratioClass defining and technologically advanced engine to meet stringent exhaust emission norms as per the latest MoEF notificationThe Cummins® diesel generator sets are available with the lowest noise levels in its rangeHighly reliable and durable productMaximum efficiency even at part loads, offering the advantage of lowest operating costs500 Hours/ 1 year service intervalIndustry acknowledged best-in-class comprehensive warranty on the entire package including rubber componentsAll the major components - the engine, alternator, aftertreatment system, control system and canopy are designed, manufactured, and tested by Cummins IndiaBest and largest customer support network in India, capable of providing round-the-clock service and spares support
More DG sets from Cummins India
- K19 Series500 kVA, 400 kWe Prime
- K19 Series600/625 kVA, 480/500 kWe Prime
- L8.9 Series250 kVA, 200 kWe Prime
- QSB5.9 Series140 - 160 kVA Prime
- QSB6.7 Series180 - 225 kVA, 144 - 180 kWe Prime
- QSK60 Series2000-2250 kVA Prime
- X2.5 Series7.5 - 20 kVA, 6 - 16 kWe Prime
- X3.6 Series50 - 58.5 kVA, 40 - 47 kWe Prime
Cummins India QSM15 Series, in short
The Cummins India QSM15 Series is a DG set rated 380 kVA, with rating basis Prime, fuel Diesel and CPCB IV+. 2 other DG sets at 380 kVA are listed, from 2 makers. Cummins India has 8 other DG sets on this site.
Same size from other makers: Jakson Group JSP-IV, Sudhir Power CS D5P series · All 380 kVA side by side
Questions about the Cummins India QSM15 Series
- What are the main specifications of the Cummins India QSM15 Series?
- Rated 380 kVA; Rating basis Prime; Fuel Diesel; CPCB IV+. As printed on Cummins India's datasheet (checked November 2026); the full list is on this page.
- Where can I find the Cummins India QSM15 Series datasheet?
- Cummins India publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
- What are the alternatives to the Cummins India QSM15 Series?
- Other 380 kVA DG sets sold in India include Jakson Group JSP-IV and Sudhir Power CS D5P series. All of them are compared side by side on the 380 kVA page.
- Who makes the Cummins India QSM15 Series?
- Cummins India, with its head office in Pune. It has 9 DG sets on this site, including this one.
Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.
Values as Cummins India prints them in the linked datasheet; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Cummins India. Product and company names are trademarks of their owners, used only to identify the product.