500 kVA DG sets (diesel and gas generator sets) in India

11 products from 8 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026

500 kVA is a standard size for large industrial and commercial sites and for data centres that run several sets in parallel. Check the rating basis, engine and control panel, and the space and foundation the set needs.

500 kVA compared

A–Z by company, not ranked · NA: not published by the maker

FieldCummins IndiaK19 Series500 kVA, 400 kWe PrimeCummins IndiaQSM15 Series380 - 500 kVA, 304 - 400 kWe PrimeForce MTU Power SystemsSeries 1600Diesel generator sets, made by Force MTUGenlite EngineeringSterling Green SGB PR-IVBaudouin-engined diesel gensets, 320 to 750 kVAJakson GroupJSP-IVSilent diesel generating sets, radiator cooled, 7.5 to 750 kVAKirloskar Oil EnginesKG4-500WS500 kVA Diesel GeneratorKirloskar Oil EnginesKG4-500WS NG1500 kVA Natural Gas GeneratorKirloskar Oil EnginesOptiprime 500 kVA500 kVA OptiprimeMahindra PowerolM10DR to M650DRAcoustic DG sets, 10 to 650 kVAOjus Power and Technologies500 kVADiesel genset modelSudhir PowerCS D5P seriesCummins-powered silent diesel gensets (2023 brochure)
Output
Rating 500 kVA380–500 kVA500–910 kVA320–750 kVA7.5–750 kVA500 kVA500 kVA500 kVA10–650 kVA500 kVA7.5–2250 kVA
Power output 400 kWefrom 304 kWeNA256–600 kWe6–600 kWe400 kWeNA400 kWe8–520 kWe400 kWeNA
Printed ratings 500 kVA380, 400, 500 kVANA320, 400, 450, 500, 650, 750 kVA7.5, 10, 15, 18.5, 20, 25, 27.5, 30, 35, 40, 41, 50, 58.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 320, 380, 400, 500, 650, 750 kVA500 kVA500 kVA500 kVA10, 15, 20, 25, 30, 35, 40, 45, 50, 58.5, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 400, 500, 525, 650 kVANA7.5, 10, 15, 20, 25, 30, 35, 40, 50, 62.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 275, 300, 320, 380, 400, 500, 600, 625, 650, 750, 810, 910, 1010, 1250, 1500, 1800, 2000, 2250 kVA
Rating basis PrimePrimeNANANAPrimeNAPrimeNAPrimePrime
Output voltage 415415NA415NA415 (3ɸ)230 V415 (3ɸ)230/415 (10 to 40 kVA), 415 (3 phase) above415NA
Frequency 50 Hz50 HzNA50 HzNA50 Hz50 Hz50 Hz50 Hz50 HzNA
Power factor 0.8 (lagging)0.8 (lagging)NA0.8NA0.8NA0.80.8 lagging0.8NA
Phase 3-phase3-phaseNANA1-phase, 3-phase3-phaseNA3-phase1-phase, 3-phase3-phaseNA
Build
Fuel DieselDieselDieselDieselDieselDieselGasDieselNADieselNA
Engine Cummins KTAA19-G10Cummins QSM15-G1MTU Series 1600Baudouin 6M21G0D4/5 to 6M33G4D4/5X2.5-G5 to QSK19-G30 (and others)DV8ETA 4G3DV12TA NG16K1080ETA 4G2Mahindra M2155G1 and others; Perkins 2806FA-E18TAG1 and 2806FA-E18TAG2 for 400 to 650 kVABaudouin 6M21G6D4/5X1.3TAA-G1, X1.3TAA-G7
Alternator Stamford HCI544DSTAMFORD HCI444E, HCI444F and HCI544DNALeroy Somer and Stamford make, brushless, self excited, IP 23, class H/H insulation, single bearingNANANANACG/LS/EquivalentStamford HCI544VNA
Enclosure AcousticAcousticNANAAcousticAcousticAcousticAcousticAcousticNAAcoustic
Dimensions (L × W × H) 6000 × 2000 × 2250 mm (axes not stated)5300 × 1900 × 2490 mm (axes not stated)NA7200 × 2200 × 3395 mm (axes not stated)6800 × 2050 × 2860 mm (axes not stated)5575 × 2125 × 2610 mm (axes not stated)6518 × 2123 × 2708 mm (axes not stated)3050 × 2130 × 1442 mm (axes not stated)5800 × 2200 × 2300 mm (axes not stated)5700 × 2100 × 3113 mm (axes not stated)10450 × 3500 × 3800 mm (axes not stated)
Fuel tank capacity 690715 to 745NA900 to 99085 to 980NANANA55 to 800900NA
Weight about 7600 kgabout 5515–5915 kgNAabout 6480–8800 kgabout 772–10156 kg6435 kg7800 kg6160 kg690–3920 kg6871 kgNA
Certification
CPCB IV+ NAYesNAYesYesYesNAYesNANANA
Certifications and standards IS/IEC 60034-1, ISO 8528, ISO 3046, IS 1460, ISO 9001, IS 13018IS/IEC 60034-1, ISO 8528, ISO 3046, IS 1460, ISO 9001, IS 13018NAISO, AS/NZ, IEC, IEEE, BSNAISO 8528ISO 8528ISO 8528IS/IEC60034-1 (alternator)ISO 8528, ISO 3046-1, ISO 15550NA
Performance
Governing class ISO 8528-5 G2ISO 8528-5 G2NAG3G2/G3G3NANAG2/G3G3 as per ISO 8528-5NA
Fuel consumption 79.83 L/h at 75% loadNANA117 L/h at 75% load (largest set)NANANANANA75.4 L/h at 75% loadNA
Noise level 75 dBA at 1 m, 75% load, free field75 dBA at 1 m, 75% load, free fieldNANANA<75 dBA< 75 dB(A)<75 DBANANA75 dBA at 1 m
Controls
Controller Cummins PowerCommand 1.2Cummins PowerStart PS0602NADEIF SGC 420 MKNANANANAGC 1115 (10 to 200 kVA), GC 1116 (250 and 320 kVA), DSE7320 (400 to 650 kVA)DEIF SGC 420 MK IIPS0600/1/2 (15-1010 kVA); PCC 3201 (1250-3750 kVA)
Support
Warranty 5 Yrs engine critical parts warranty5 Yrs engine critical parts warrantyNANA5C Warranty (5 years/ 5000 hours)NANA5-year standard warrantyStandard warranty of 2 Years/5000 Hours, 5 Years 5C warrantyNANA
Source
NotePower range as printed on the company product page.Sheet lists six models from 320 to 750 kVA. Higher ratings are available on request.Dimensions, weight and day fuel tank are for the acoustic set.
Model codeC500D5PCI 380D5P, CI 400D5P, CI 500D5PFM500, FM610, FM1000SGB 320 PR-IV, SGB 400 PR-IV, SGB 450 PR-IV, SGB 500 PR-IV, SGB 650 PR-IV, SGB 750 PR-IVJSP-IV 7.5 to JSP-IV 750NANANAM10DR to M650DRNACS 7.5 D5P to CS 2250 D5P
DatasheetDatasheet (PDF) of Cummins India K19 Series (opens the maker's site)Datasheet (PDF) of Cummins India QSM15 Series (opens the maker's site)Spec page of Force MTU Power Systems Series 1600 (opens the maker's site)Datasheet (PDF) of Genlite Engineering Sterling Green SGB PR-IV (opens the maker's site)Datasheet (PDF) of Jakson Group JSP-IV (opens the maker's site)Spec page of Kirloskar Oil Engines KG4-500WS (opens the maker's site)Spec page of Kirloskar Oil Engines KG4-500WS NG1 (opens the maker's site)Spec page of Kirloskar Oil Engines Optiprime 500 kVA (opens the maker's site)Datasheet (PDF) of Mahindra Powerol M10DR to M650DR (opens the maker's site)Datasheet (PDF) of Ojus Power and Technologies 500 kVA (opens the maker's site)Datasheet (PDF) of Sudhir Power CS D5P series (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026
DetailsDetails of Cummins India K19 SeriesDetails of Cummins India QSM15 SeriesDetails of Force MTU Power Systems Series 1600Details of Genlite Engineering Sterling Green SGB PR-IVDetails of Jakson Group JSP-IVDetails of Kirloskar Oil Engines KG4-500WSDetails of Kirloskar Oil Engines KG4-500WS NG1Details of Kirloskar Oil Engines Optiprime 500 kVADetails of Mahindra Powerol M10DR to M650DRDetails of Ojus Power and Technologies 500 kVADetails of Sudhir Power CS D5P series

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 11 products above, as printed.

  • Rating: 7.5 to 2250 kVA as printed (ranges included)
  • Power output: 6 to 600 kWe as printed (ranges included); 3 not published
  • Rating basis: Prime; 6 of 11 publish it
  • Fuel: 8 Diesel, 1 Gas; 2 not published
  • CPCB IV+: 5 of 11; 6 not published
  • Output voltage: 8 of 11 publish it; values in the table
  • Frequency: 50 Hz; 8 of 11 publish it
  • Power factor: 0.8 on 4, 0.8 (lagging) on 2, 0.8 lagging on 1; 4 not published
  • Governing class: 7 of 11 publish it; values in the table
  • Phase: 7 of 11 publish a list; 3-phase on 7, 1-phase on 2
  • Engine: 11 of 11 publish it; values in the table
  • Alternator: 5 of 11 publish it; values in the table
  • Enclosure: Acoustic; 8 of 11 publish it
  • Fuel consumption: 3 of 11 publish it; values in the table
  • Noise level: 6 of 11 publish it; values in the table
  • Controller: 6 of 11 publish it; values in the table
  • Dimensions (L × W × H): 10 of 11 publish it; values in the table
  • Fuel tank capacity: 55 to 800 on 1, 690 on 1, 715 to 745 on 1, 85 to 980 on 1, 900 on 1, 900 to 990 on 1; 5 not published
  • Weight: 690 to 10156 kg as printed (ranges included); 2 not published (4 printed as approximate)
  • Warranty: 5 of 11 publish it; values in the table
  • Certifications and standards: 8 of 11 publish a list; ISO 8528 on 6, IS 13018 on 2, IS 1460 on 2, IS/IEC 60034-1 on 2

Questions about 500 kVA DG sets (diesel and gas generator sets)

Which companies make 500 kVA DG sets (diesel and gas generator sets) in India?
8 companies list 11 products at this size: Cummins India (K19 Series, QSM15 Series); Force MTU Power Systems (Series 1600); Genlite Engineering (Sterling Green SGB PR-IV); Jakson Group (JSP-IV); Kirloskar Oil Engines (KG4-500WS, KG4-500WS NG1, Optiprime 500 kVA); Mahindra Powerol (M10DR to M650DR); Ojus Power and Technologies (500 kVA); Sudhir Power (CS D5P series). They are listed A–Z by company, not ranked.
How do these 500 kVA DG sets (diesel and gas generator sets) differ?
Rating: 7.5 to 2250 kVA as printed (ranges included). Power output: 6 to 600 kWe as printed (ranges included); 3 not published. Rating basis: Prime; 6 of 11 publish it. Fuel: 8 Diesel, 1 Gas; 2 not published. Counted from the 11 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 500 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.