4 products from 4 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026
A 5 kVA DG set backs up a home, a small shop or a site office: lights, fans, a refrigerator and a few appliances. Most at this size are single-cylinder, air- or water-cooled sets in an acoustic canopy, sold in single-phase or three-phase versions. Check whether the rating printed is prime or standby, since the two are not the same figure.
5 kVA compared
A–Z by company, not ranked · NA: not published by the maker
| Field | Cooper CorporationCooper Diesel Genset 5 kVA | Jakson Group5 kVA GensetXtra, low kVA genset | Mahindra PowerolMM8.205SSI(R1)-C25 kVA air-cooled single-cylinder genset | Pinnacle Generators5 kVAGenset model PG-5 |
|---|---|---|---|---|
| Output | ||||
| Rating | 5 kVA | 5 kVA | 5 kVA | 5 kVA |
| Power output | 4 kWe | 4 kWe | NA | NA |
| Printed ratings | 5 kVA | 5 kVA | 5 kVA | 5 kVA |
| Rating basis | NA | NA | NA | Prime |
| Output voltage | NA | 230V Single Phase | 230 | 230 V AC / 415 V AC |
| Frequency | NA | 50 Hz | 50 Hz | 50 Hz |
| Power factor | NA | NA | 0.8 | 0.8 lag |
| Phase | 1-phase | 1-phase | NA | 1-phase, 3-phase |
| Build | ||||
| Fuel | Diesel | Diesel | NA | NA |
| Engine | NA | JAKSON JP186F | Lombardini KD441-GSI2 | Eicher Engines 110A1-EG008 |
| Alternator | NA | Brushless, Self-Excited | NSM mPower61565GC | CG / Leroy Somer / Meccalte / Stamford |
| Enclosure | Acoustic | Acoustic | NA | Acoustic |
| Dimensions (L × W × H) | 1162 × 560 × 819 mm (axes not stated) | 650 × 500 × 550 mm (axes not stated) | 1050 × 620 × 745 mm (axes not stated) | 1500 × 850 × 1250 mm (axes not stated) |
| Fuel tank capacity | NA | 12 | 15 | 50 |
| Weight | 213 kg | 85 kg | 210 kg | 692 kg |
| Certification | ||||
| CPCB IV+ | Yes | Yes | NA | NA |
| Certifications and standards | NA | NA | NA | ISO 3046-1, ISO 8528 |
| Performance | ||||
| Governing class | NA | NA | NA | Mechanical G2 |
| Fuel consumption | NA | 1.2 L/Hr @ 75% Load | 1.14 L/h at 75% load | NA |
| Noise level | NA | ≤ 68 dB(A) | NA | NA |
| Controls | ||||
| Controller | NA | NA | AMF/MCP | TMTL Genset Control Unit |
| Support | ||||
| Warranty | NA | NA | NA | Warranty period covers 2 Years or 5000 Hours run* (whichever is earlier). Warranty on 5C covers 5 Years or 5000 Hours run* (whichever is earlier). * Terms and conditions apply |
| Source | ||||
| Note | Specifications as printed on the maker's product page; no PDF datasheet linked. | |||
| Model code | NA | JP186F (engine) | NA | NA |
| Datasheet | Spec page of Cooper Corporation Cooper Diesel Genset 5 kVA (opens the maker's site) | Spec page of Jakson Group 5 kVA Genset (opens the maker's site) | Spec page of Mahindra Powerol MM8.205SSI(R1)-C2 (opens the maker's site) | Spec page of Pinnacle Generators 5 kVA (opens the maker's site) |
| CheckedFigures compared with the maker's sheet | November 2026 | November 2026 | November 2026 | November 2026 |
| Details | Details of Cooper Corporation Cooper Diesel Genset 5 kVA | Details of Jakson Group 5 kVA Genset | Details of Mahindra Powerol MM8.205SSI(R1)-C2 | Details of Pinnacle Generators 5 kVA |
Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.
What differs between them
Counted from the 4 products above, as printed.
- Rating: 5 kVA on all 4
- Power output: 4 kWe; 2 of 4 publish it
- Rating basis: Prime; 1 of 4 publishes it
- Fuel: Diesel; 2 of 4 publish it
- CPCB IV+: 2 of 4; 2 not published
- Output voltage: 3 of 4 publish it; values in the table
- Frequency: 50 Hz; 3 of 4 publish it
- Power factor: 0.8 on 1, 0.8 lag on 1; 2 not published
- Governing class: Mechanical G2; 1 of 4 publishes it
- Phase: 3 of 4 publish a list; 1-phase on 3
- Engine: 3 of 4 publish it; values in the table
- Alternator: 3 of 4 publish it; values in the table
- Enclosure: Acoustic; 3 of 4 publish it
- Fuel consumption: 2 of 4 publish it; values in the table
- Noise level: ≤ 68 dB(A); 1 of 4 publishes it
- Controller: 2 of 4 publish it; values in the table
- Dimensions (L × W × H): 4 of 4 publish it; values in the table
- Fuel tank capacity: 12 on 1, 15 on 1, 50 on 1; 1 not published
- Weight: 85 to 692 kg as printed
- Warranty: Warranty period covers 2 Years or 5000 Hours run* (whichever is earlier). Warranty on 5C covers 5 Years or 5000 Hours run* (whichever is earlier). * Terms and conditions apply; 1 of 4 publishes it
- Certifications and standards: 1 of 4 publish a list
Nearby rating values
A page needs 3+ products from 3+ companies; values without one are in the full list by rating.
Questions about 5 kVA DG sets (diesel and gas generator sets)
- Which companies make 5 kVA DG sets (diesel and gas generator sets) in India?
- 4 companies list 4 products at this size: Cooper Corporation (Cooper Diesel Genset 5 kVA); Jakson Group (5 kVA Genset); Mahindra Powerol (MM8.205SSI(R1)-C2); Pinnacle Generators (5 kVA). They are listed A–Z by company, not ranked.
- How do these 5 kVA DG sets (diesel and gas generator sets) differ?
- Rating: 5 kVA on all 4. Power output: 4 kWe; 2 of 4 publish it. Rating basis: Prime; 1 of 4 publishes it. Fuel: Diesel; 2 of 4 publish it. Counted from the 4 products as each maker prints them.
- Where do these figures come from?
- From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 5 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.
Is your company on this list? Add it, update your details or raise a concern →