60 kVA DG sets (diesel and gas generator sets) in India

3 products from 3 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026

60 kVA sets serve small and medium industrial units, hospitals and office buildings. Three-phase canopied sets are the norm; compare the governing class, fuel use and noise if the set will run near people.

60 kVA compared

A–Z by company, not ranked · NA: not published by the maker

FieldAshok LeylandLeypowerCPCB4+ Diesel Genset, LP15 to LP250Ojus Power and TechnologiesOL seriesDiesel generators, 15 to 250 kVAPinnacle Generators60 kVAGenset model PG -60
Output
Rating 15–250 kVA15–250 kVA60 kVA
Power output 12–200 kWe12–200 kWeNA
Printed ratings 15, 25, 30, 35, 40, 45, 60, 75, 82.5, 100, 125, 160, 180, 250 kVA15, 20, 25, 30, 35, 40, 45, 60, 82.5, 100, 125, 160, 180, 250 kVA60 kVA
Rating basis NANAPrime
Output voltage NANA415 V AC
Frequency NANA50 Hz
Power factor NANA0.8 lag
Phase NANA3-phase
Build
Fuel DieselDieselNA
Engine H2G4DM15, P15G4DE25 and othersH2G4DM15, ALG184, P15G4DE25 and othersTMTL Engines 333W0-EG060
Alternator NANACG / Leroy Somer / Meccalte / Stamford
Enclosure AcousticNAAcoustic
Dimensions (L × W × H) 4700 × 1600 × 2020 mm (axes not stated)4700 × 1600 × 2020 mm (axes not stated)2500 × 1100 × 1575 mm (axes not stated)
Fuel tank capacity 55 to 34050 to 340125
Weight about 676–4500 kgabout 676–4500 kg1375 kg
Certification
CPCB IV+ YesYesNA
Certifications and standards BS 5514, ISO 3046, ISO 8528BS 5514, ISO 3046, ISO 8528ISO 3046-1, ISO 8528
Performance
Governing class A0 (A1 on LP15)A1 (OL 15, OL 20); A0 (OL 25 to OL 250)CRS Electronic G3
Fuel consumption NANANA
Noise level NANANA
Controls
Controller GC 902 and GC 1206GC 1207 (OL 15), DEIF SGC120 (OL 20), GC 1206 (OL 25 to OL 250)TMTL Genset Control Unit
Support
Warranty NA5 Years or 8000 hrs, T&C apply (OL 20: 2 years or 5000 hrs whichever occurs earlier)Warranty period covers 2 Years or 5000 Hours run* (whichever is earlier). Warranty on 5C covers 5 Years or 5000 Hours run* (whichever is earlier). * Terms and conditions apply
Source
NoteSeries of 13 diesel sets from 15 kVA to 250 kVA; each set has its own specification page on the maker's site.Sheet prints the ratings, engine models, tank size and weight for 13 models.
Model codeLP15, LP25, LP30, LP35/40, LP45, LP60, LP75/82.5, LP100, LP125, LP160, LP180, LP250OL 15, OL 20, OL 25, OL 30, OL 35/40, OL 45, OL 60, OL 82.5, OL 100, OL 125, OL 160, OL 180, OL 250NA
DatasheetSpec page of Ashok Leyland Leypower (opens the maker's site)Datasheet (PDF) of Ojus Power and Technologies OL series (opens the maker's site)Spec page of Pinnacle Generators 60 kVA (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026
DetailsDetails of Ashok Leyland LeypowerDetails of Ojus Power and Technologies OL seriesDetails of Pinnacle Generators 60 kVA

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 3 products above, as printed.

  • Rating: 15 to 250 kVA as printed (ranges included)
  • Power output: 12 to 200 kWe as printed (ranges included); 1 not published
  • Rating basis: Prime; 1 of 3 publishes it
  • Fuel: Diesel; 2 of 3 publish it
  • CPCB IV+: 2 of 3; 1 not published
  • Output voltage: 415 V AC; 1 of 3 publishes it
  • Frequency: 50 Hz; 1 of 3 publishes it
  • Power factor: 0.8 lag; 1 of 3 publishes it
  • Governing class: 3 of 3 publish it; values in the table
  • Phase: 1 of 3 publish a list
  • Engine: 3 of 3 publish it; values in the table
  • Alternator: CG / Leroy Somer / Meccalte / Stamford; 1 of 3 publishes it
  • Enclosure: Acoustic; 2 of 3 publish it
  • Controller: 3 of 3 publish it; values in the table
  • Dimensions (L × W × H): 3 of 3 publish it; values in the table
  • Fuel tank capacity: 125 on 1, 50 to 340 on 1, 55 to 340 on 1
  • Weight: 676 to 4500 kg as printed (ranges included) (2 printed as approximate)
  • Warranty: 2 of 3 publish it; values in the table
  • Certifications and standards: 3 of 3 publish a list; ISO 8528 on 3, BS 5514 on 2, ISO 3046 on 2

Questions about 60 kVA DG sets (diesel and gas generator sets)

Which companies make 60 kVA DG sets (diesel and gas generator sets) in India?
3 companies list 3 products at this size: Ashok Leyland (Leypower); Ojus Power and Technologies (OL series); Pinnacle Generators (60 kVA). They are listed A–Z by company, not ranked.
How do these 60 kVA DG sets (diesel and gas generator sets) differ?
Rating: 15 to 250 kVA as printed (ranges included). Power output: 12 to 200 kWe as printed (ranges included); 1 not published. Rating basis: Prime; 1 of 3 publishes it. Fuel: Diesel; 2 of 3 publish it. Counted from the 3 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 60 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.