3 products from 3 companies, side by side. All 122 products in DG sets · Listed A–Z, not ranked · Reviewed November 2026
62.5 kVA is a standard Indian DG size for mid-size commercial and industrial sites: offices, hotels, schools and workshops with motors. Check whether the figure is prime or standby, and the emission compliance printed for the engine.
62.5 kVA compared
A–Z by company, not ranked · NA: not published by the maker
| Field | Cooper CorporationCooper Diesel Genset 62.5 kVA | Mahindra PowerolM10DR to M650DRAcoustic DG sets, 10 to 650 kVA | Sudhir PowerCS D5P seriesCummins-powered silent diesel gensets (2023 brochure) |
|---|---|---|---|
| Output | |||
| Rating | 62.5 kVA | 10–650 kVA | 7.5–2250 kVA |
| Power output | 50 kWe | 8–520 kWe | NA |
| Printed ratings | 62.5 kVA | 10, 15, 20, 25, 30, 35, 40, 45, 50, 58.5, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 400, 500, 525, 650 kVA | 7.5, 10, 15, 20, 25, 30, 35, 40, 50, 62.5, 82.5, 100, 125, 140, 160, 180, 200, 225, 250, 275, 300, 320, 380, 400, 500, 600, 625, 650, 750, 810, 910, 1010, 1250, 1500, 1800, 2000, 2250 kVA |
| Rating basis | NA | NA | Prime |
| Output voltage | NA | 230/415 (10 to 40 kVA), 415 (3 phase) above | NA |
| Frequency | NA | 50 Hz | NA |
| Power factor | NA | 0.8 lagging | NA |
| Phase | 3-phase | 1-phase, 3-phase | NA |
| Build | |||
| Fuel | Diesel | NA | NA |
| Engine | NA | Mahindra M2155G1 and others; Perkins 2806FA-E18TAG1 and 2806FA-E18TAG2 for 400 to 650 kVA | X1.3TAA-G1, X1.3TAA-G7 |
| Alternator | NA | CG/LS/Equivalent | NA |
| Enclosure | Acoustic | Acoustic | Acoustic |
| Dimensions (L × W × H) | 2750 × 1080 × 1503 mm (axes not stated) | 5800 × 2200 × 2300 mm (axes not stated) | 10450 × 3500 × 3800 mm (axes not stated) |
| Fuel tank capacity | NA | 55 to 800 | NA |
| Weight | 1750 kg | 690–3920 kg | NA |
| Certification | |||
| CPCB IV+ | Yes | NA | NA |
| Certifications and standards | NA | IS/IEC60034-1 (alternator) | NA |
| Performance | |||
| Governing class | NA | G2/G3 | NA |
| Fuel consumption | NA | NA | NA |
| Noise level | NA | NA | 75 dBA at 1 m |
| Controls | |||
| Controller | NA | GC 1115 (10 to 200 kVA), GC 1116 (250 and 320 kVA), DSE7320 (400 to 650 kVA) | PS0600/1/2 (15-1010 kVA); PCC 3201 (1250-3750 kVA) |
| Support | |||
| Warranty | NA | Standard warranty of 2 Years/5000 Hours, 5 Years 5C warranty | NA |
| Source | |||
| Note | Specifications as printed on the maker's product page; no PDF datasheet linked. | ||
| Model code | NA | M10DR to M650DR | CS 7.5 D5P to CS 2250 D5P |
| Datasheet | Spec page of Cooper Corporation Cooper Diesel Genset 62.5 kVA (opens the maker's site) | Datasheet (PDF) of Mahindra Powerol M10DR to M650DR (opens the maker's site) | Datasheet (PDF) of Sudhir Power CS D5P series (opens the maker's site) |
| CheckedFigures compared with the maker's sheet | November 2026 | November 2026 | November 2026 |
| Details | Details of Cooper Corporation Cooper Diesel Genset 62.5 kVA | Details of Mahindra Powerol M10DR to M650DR | Details of Sudhir Power CS D5P series |
Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Each rating is shown with the basis its maker prints (prime, standby or not stated); prime and standby figures are not the same and shouldn't be compared directly. A range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.
What differs between them
Counted from the 3 products above, as printed.
- Rating: 7.5 to 2250 kVA as printed (ranges included)
- Power output: 8 to 520 kWe as printed (ranges included); 1 not published
- Rating basis: Prime; 1 of 3 publishes it
- Fuel: Diesel; 1 of 3 publishes it
- CPCB IV+: 1 of 3; 2 not published
- Output voltage: 230/415 (10 to 40 kVA), 415 (3 phase) above; 1 of 3 publishes it
- Frequency: 50 Hz; 1 of 3 publishes it
- Power factor: 0.8 lagging; 1 of 3 publishes it
- Governing class: G2/G3; 1 of 3 publishes it
- Phase: 2 of 3 publish a list; 3-phase on 2
- Engine: 2 of 3 publish it; values in the table
- Alternator: CG/LS/Equivalent; 1 of 3 publishes it
- Enclosure: Acoustic on all 3
- Noise level: 75 dBA at 1 m; 1 of 3 publishes it
- Controller: 2 of 3 publish it; values in the table
- Dimensions (L × W × H): 3 of 3 publish it; values in the table
- Fuel tank capacity: 55 to 800; 1 of 3 publishes it
- Weight: 690 to 3920 kg as printed (ranges included); 1 not published
- Warranty: Standard warranty of 2 Years/5000 Hours, 5 Years 5C warranty; 1 of 3 publishes it
- Certifications and standards: 1 of 3 publish a list
Nearby rating values
A page needs 3+ products from 3+ companies; values without one are in the full list by rating.
Questions about 62.5 kVA DG sets (diesel and gas generator sets)
- Which companies make 62.5 kVA DG sets (diesel and gas generator sets) in India?
- 3 companies list 3 products at this size: Cooper Corporation (Cooper Diesel Genset 62.5 kVA); Mahindra Powerol (M10DR to M650DR); Sudhir Power (CS D5P series). They are listed A–Z by company, not ranked.
- How do these 62.5 kVA DG sets (diesel and gas generator sets) differ?
- Rating: 7.5 to 2250 kVA as printed (ranges included). Power output: 8 to 520 kWe as printed (ranges included); 1 not published. Rating basis: Prime; 1 of 3 publishes it. Fuel: Diesel; 1 of 3 publishes it. Counted from the 3 products as each maker prints them.
- Where do these figures come from?
- From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 62.5 kVA are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.
Is your company on this list? Add it, update your details or raise a concern →