36 kW solar inverters in India

16 products from 8 companies, side by side. All 293 products in Solar inverters · Listed A–Z, not ranked · Reviewed November 2026

36 kW is a three-phase commercial size with up to six MPPTs, so large roofs with several orientations can use one unit. Most products are string inverters; four are hybrids.

36 kW compared

A–Z by company, not ranked · NA: not published by the maker

Compare these (12)
A comparison holds 12; hide some to choose which.
FieldDeyeSUN-29.9K-SG01HP3-EU-BM3SUN-29.9/30/35K-SG01HP3-EU-BM3 / SUN-40/50K-SG01HP3-EU-BM4DeyeSUN-29.9K-SG02HP3-EU-BM3-PSUN-29.9/30/35K-SG02HP3-EU-BM3-P / SUN-40/50K-SG02HP3-EU-BM4-PDeyeSUN-30/33/35/36K-G04DeyeSUN-33/35/40/45/50K-G04P3-EU-AM4-LVFox ESSU SeriesFox ESSV SeriesGoodWeSDT G3 25-40kWGoodWeSDT G3 30-50kWGoodWeSMT G2GrowattMID 33-50KTL3-X2GrowattMID 36-60KTL3-X3GrowattWIT 29.9-50K-XHUKSolare5G PRO Three PhaseSolaX PowerX3-AELIO 36KSolisS6-GC3P(25-40)K03-NDThree phase grid-tied, 3 MPPTSungrowSG36CX-P2 to SG50CX-P2
Overview
Type HybridHybridStringStringStringStringStringStringStringStringStringHybridStringHybridStringString
Rated AC power 29.9–50 kW29.9–50 kW30–36 kW33–50 kW30–40 kW30–75 kW25–40 kW30–50 kW35–80 kW33–50 kW36–60 kW29.9–50 kW3–35 kW36–60 kW25–40 kW36–50 kW
Printed ratings 29.9, 30, 35, 40, 50 kW29.9, 30, 35, 40, 50 kW30, 33, 35, 36 kW33, 35, 40, 45, 50 kW30, 33, 36, 40 kW30, 33, 36, 40, 50, 60, 75 kW25, 30, 33, 36, 40 kW30, 33, 36, 40, 50 kW35, 37.5, 50, 60, 75, 80 kW33, 36, 40, 50 kW36, 40, 50, 60 kW29.9, 30, 36, 40, 50 kW3, 4, 5, 6, 7, 8, 10, 12, 15, 20, 25, 30, 33, 35 kW36, 37.5, 60 kW25, 30, 33, 36, 40 kW36, 40, 50 kW
Phases 3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase3-phase
DC input
MPPTs NANA243NANANANANANA4NA634
Max DC voltage 1000 V1000 V1100 V800 V1100 V1100 V1100 V1100 V1100 V1100 V1100 V1100 V1000 V1000 V1100 V1100 V
MPPT voltage range 150–850 V150–850 V200–1000 V200–700 V200–1000 V200–1000 VNANANA200–1000 V160–1000 V180–1000 V200–1000 VNA180–1000 V160–1000 V
Strings per MPPT 223NA222222NA2NA2NA2
Max current per MPPT 36 A36 A40 A40 A40 A40 A42 A42 A42 A32 A40 A40 A16 A40 A42 A30 A
Max PV array 80 kW80 kW54 kW75 kW60 kWNANANANANANA100 kW40 kW120 kW60 kW70 kW
Efficiency
Max efficiency 97.6 %97.6 %98.6 %98.7 %98.3 %98.7 %98.7 %98.7 %98.8 %98.8 %98.8 %98.1 %98 %98 %98.6 %98.5 %
European efficiency 97 %97 %98.1 %NA98.1 %NANANANANA98.5 %NA97.5 %97.2 %98.1 %98.3 %
AC output
Max AC apparent power 55 kVA55 kVA39.6 kVA50 kVA44 kVA75 kVA40 kVA50 kVA88 kVA55.5 kVA66.6 kVA55 kVANANA40 kVA55 kVA
Battery
Battery Lithium-ionLithium-ionNANANANANANANANANANANALithium-ionNANA
Battery voltage 160–800 V160–800 VNANANANANANANANANA200–900 VNANANANA
Max charge/discharge current 50 A160 ANANANANANANANANANANANA160 ANANA
Max charge/discharge NANANANANANANANANANANANANANANANA
Build
IP rating IP65IP65IP65IP65IP66IP66IP66IP66IP66IP66IP66IP66IP65IP66IP66IP66
Weight 80 kg65 kg28.7 kg53.7 kg33 kgNANANANANANA90 kgNAup to 105 kg26.5 kgNA
Warranty 5 years5 years5 years5 yearsNANANANANA5 years5 years5 years10 yearsNANANA
Compliance
Certifications IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2NAEN 50549-1NANANACE, EN 50549-1, IEC 62116, IEC 61727, BIS, TOR Erzeuger Typ A, IEC 62910, IEC 61683, IEC 60068, CEI 021, CEI 016, CQC, DRRG, KS, N4105, UKCA, VDE 0126, C10/C11, INMETRO, UNE217001, UNE217002, NTS Type A, Polond, DenmarkCE, IEC 61683/60068, IEC 62116/61727, RD 1699, INMETROCE/CB, ROHS, IEC 62109-1, IEC 62109-2, IEC 62477-1, EN 62920, IEC 61000-6-4, IEC 61000-6-2, IEC 61000-3-12, IEC 61000-3-11, EN 55011, IEC 62116, IEC 61727, IEC 61683, IEC 60068-2-1, NRS 097-2-1NACE, VDE 4105, G99, AS 4777, EN 50549, CEI 0-21, IEC 61727, PEA/MEA, NRS-097-2-1, RD1699, TOR, InmetroIEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4IEC 62109, IEC 61727, IEC 62116
Source
Model codeNANANANAU30, U33, U36, U40V30, V33, V36, V40, V50, V60, V75GW25K-SDT-30, GW30K-SDT-30, GW33K-SDT-C30, GW36K-SDT-C30, GW40K-SDT-C30, GW40K-SDT-P30SDT-C30 and SDT-30 models, 30 to 50 kW (full codes in the datasheet header not captured; the sheet header wraps)GW35K-SMT-L-G20, GW37.5K-SMT-L-G20, GW60K-SMT-G20, GW50K-SMT-L-G10, GW75K-SMT, GW80K-SMTMID 33KTL3-X2, MID 36KTL3-X2, MID 40KTL3-X2, MID 50KTL3-X2MID 36KTL3-X3, MID 40KTL3-X3, MID 50KTL3-X3, MID 60KTL3-X3WIT 29.9K-XHU, WIT 30K-XHU, WIT 36K-XHU, WIT 40K-XHU, WIT 50K-XHU3kW, 4kW, 5kW, 6kW, 7kW, 8kW, 10kW, 12kW, 15kW, 20kW, 25kW, 30kW, 33kW, 35kWX3-AELIO-36K, -37.5K, -60KS6-GC3P25K03-NV-ND, 30K03-NV, 33K03-NV, 36K03-NV, 40K03-HVSG36CX-P2 / SG40CX-P2 / SG50CX-P2
DatasheetDatasheet (PDF) of Deye SUN-29.9K-SG01HP3-EU-BM3 (opens the maker's site)Datasheet (PDF) of Deye SUN-29.9K-SG02HP3-EU-BM3-P (opens the maker's site)Datasheet (PDF) of Deye SUN-30/33/35/36K-G04 (opens the maker's site)Datasheet (PDF) of Deye SUN-33/35/40/45/50K-G04P3-EU-AM4-LV (opens the maker's site)Datasheet (PDF) of Fox ESS U Series (opens the maker's site)Datasheet (PDF) of Fox ESS V Series (opens the maker's site)Datasheet of GoodWe SDT G3 25-40kW (opens the maker's site)Datasheet of GoodWe SDT G3 30-50kW (opens the maker's site)Datasheet of GoodWe SMT G2 (opens the maker's site)Datasheet (PDF) of Growatt MID 33-50KTL3-X2 (opens the maker's site)Datasheet (PDF) of Growatt MID 36-60KTL3-X3 (opens the maker's site)Datasheet (PDF) of Growatt WIT 29.9-50K-XHU (opens the maker's site)Datasheet (PDF) of KSolare 5G PRO Three Phase (opens the maker's site)Datasheet (PDF) of SolaX Power X3-AELIO 36K (opens the maker's site)Datasheet (PDF) of Solis S6-GC3P(25-40)K03-ND (opens the maker's site)Datasheet (PDF) of Sungrow SG36CX-P2 to SG50CX-P2 (opens the maker's site)
CheckedFigures compared with the maker's sheetNovember 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026November 2026
DetailsDetails of Deye SUN-29.9K-SG01HP3-EU-BM3Details of Deye SUN-29.9K-SG02HP3-EU-BM3-PDetails of Deye SUN-30/33/35/36K-G04Details of Deye SUN-33/35/40/45/50K-G04P3-EU-AM4-LVDetails of Fox ESS U SeriesDetails of Fox ESS V SeriesDetails of GoodWe SDT G3 25-40kWDetails of GoodWe SDT G3 30-50kWDetails of GoodWe SMT G2Details of Growatt MID 33-50KTL3-X2Details of Growatt MID 36-60KTL3-X3Details of Growatt WIT 29.9-50K-XHUDetails of KSolare 5G PRO Three PhaseDetails of SolaX Power X3-AELIO 36KDetails of Solis S6-GC3P(25-40)K03-NDDetails of Sungrow SG36CX-P2 to SG50CX-P2

Values as each maker prints them on its own datasheet or spec page, linked in the Datasheet row at the foot of the table; Checked is the date we compared these figures with the maker's sheet. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical by company.

What differs between them

Counted from the 16 products above, as printed.

  • Type: 12 String, 4 Hybrid
  • Rated AC power: 3 to 80 kW as printed (ranges included)
  • Phases: 3-phase on all 16
  • MPPTs: 2 to 6 as printed; 9 not published
  • Max DC voltage: 800 to 1100 V as printed
  • Max efficiency: 97.6 to 98.8 % as printed
  • European efficiency: 97 to 98.5 % as printed; 7 not published
  • MPPT voltage range: 150 to 1000 V as printed (ranges included); 4 not published
  • Strings per MPPT: 2 to 3 as printed; 4 not published
  • Max current per MPPT: 16 to 42 A as printed
  • Max PV array: 40 to 120 kW as printed; 6 not published
  • Max AC apparent power: 39.6 to 88 kVA as printed; 2 not published
  • Battery: Lithium-ion; 3 of 16 publish it
  • Battery voltage: 160 to 900 V as printed (ranges included); 13 not published
  • Max charge/discharge current: 50 to 160 A as printed; 13 not published
  • IP rating: IP66 on 11, IP65 on 5
  • Weight: 26.5 to 105 kg as printed; 8 not published (1 printed as an upper bound)
  • Warranty: 5 to 10 years as printed; 8 not published
  • Certifications: 11 of 16 publish a list; IEC 61727 on 4, IEC/EN 61000-6-1/2/3/4 on 4, IEC/EN 62109-1 on 4, IEC/EN 62109-2 on 4

Questions about 36 kW solar inverters

Which companies make 36 kW solar inverters in India?
8 companies list 16 products at this size: Deye (SUN-29.9K-SG01HP3-EU-BM3, SUN-29.9K-SG02HP3-EU-BM3-P, SUN-30/33/35/36K-G04, SUN-33/35/40/45/50K-G04P3-EU-AM4-LV); Fox ESS (U Series, V Series); GoodWe (SDT G3 25-40kW, SDT G3 30-50kW, SMT G2); Growatt (MID 33-50KTL3-X2, MID 36-60KTL3-X3, WIT 29.9-50K-XHU); KSolare (5G PRO Three Phase); SolaX Power (X3-AELIO 36K); Solis (S6-GC3P(25-40)K03-ND); Sungrow (SG36CX-P2 to SG50CX-P2). They are listed A–Z by company, not ranked.
How do these 36 kW solar inverters differ?
Type: 12 String, 4 Hybrid. Rated AC power: 3 to 80 kW as printed (ranges included). Phases: 3-phase on all 16. MPPTs: 2 to 6 as printed; 9 not published. Counted from the 16 products as each maker prints them.
Where do these figures come from?
From each maker's own datasheet or spec page, checked November 2026. Products printed within ±3% of 36 kW are grouped on this page, each showing its own printed figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.