Cabinet BESS products in India

Listed A–Z, not ranked · Reviewed November 2026

BESS cabinets products

  • Ashbee Energy Systems

    Magnum 261 kWh

    All In One Liquid Cooling Energy Storage System

    Rated energy
    261 kWh
    Rated power
    NA
    Duration
    2 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    64–480 kWh
    Rated power
    30–250 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    314 Ah
  • Rated energy
    NA
    Rated power
    100 kW
    Duration
    2 h
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    NA
  • Rated energy
    215 kWh
    Rated power
    100 kW
    Duration
    2.2 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    NA
  • Rated energy
    464 kWh
    Rated power
    250 kW
    Duration
    1.9 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    NA
  • Rated energy
    261 kWh
    Rated power
    125 kW
    Duration
    2.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    261 kWh
    Rated power
    125 kW
    Duration
    2.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    241 kWh
    Rated power
    n/a (no PCS)
    Duration
    NA
    PCS included
    No
    Cooling
    Air
    Cell capacity
    314 Ah
  • Cygni Energy

    CYG-HVPC

    Cygni 51.2kWh Solution: 512 V LFP floor-rack battery, 51.2 to 256 kWh

    Rated energy
    51.2–256 kWh
    Rated power
    25–125 kW
    Duration
    NA
    PCS included
    NA
    Cooling
    Air
    Cell capacity
    NA
  • Rated energy
    89–220 kWh
    Rated power
    n/a (no PCS)
    Duration
    NA
    PCS included
    No
    Cooling
    Air
    Cell capacity
    NA
  • Delta Electronics India

    SK-Series Energy Storage Skid

    LFP Battery Energy Storage Solutions

    Rated energy
    315.3–946.2 kWh
    Rated power
    100–250 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    280 Ah
  • Electres

    Electres Pro

    125 kW / 261 kWh Liquid-Cooled All-in-One BESS

    Rated energy
    261 kWh
    Rated power
    125 kW
    Duration
    2.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    50–200 kWh
    Rated power
    NA
    Duration
    NA
    PCS included
    Yes
    Cooling
    NA
    Cell capacity
    NA
  • Rated energy
    100–300 kWh
    Rated power
    NA
    Duration
    NA
    PCS included
    Yes
    Cooling
    NA
    Cell capacity
    NA
  • Rated energy
    160.77–261.25 kWh
    Rated power
    n/a (no PCS)
    Duration
    2 h
    PCS included
    No
    Cooling
    Air
    Cell capacity
    314 Ah
  • Rated energy
    250 kWh
    Rated power
    125 kW
    Duration
    2 h
    PCS included
    Yes
    Cooling
    NA
    Cell capacity
    NA
  • Rated energy
    233 kWh
    Rated power
    125 kW
    Duration
    1.9 h
    PCS included
    NA
    Cooling
    Air
    Cell capacity
    NA
  • Rated energy
    from 261 kWh
    Rated power
    NA
    Duration
    NA
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    100–225 kWh
    Rated power
    50–100 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    314 Ah
  • Rated energy
    215 kWh
    Rated power
    100 kW
    Duration
    2.2 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    261 kWh
    Rated power
    125 kW
    Duration
    2.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Sungrow

    PowerStack 255CS

    Liquid Cooled C&I Energy Storage System

    Rated energy
    257 kWh
    Rated power
    125 kW
    Duration
    2.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Sungrow

    PowerStack 255CS 125kW/514kWh

    Liquid Cooled C&I Energy Storage System

    Rated energy
    514 kWh
    Rated power
    125 kW
    Duration
    4.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Sungrow

    ST688UX-AL

    PowerStack Liquid Cooling Supplemental Cabinet

    Rated energy
    NA
    Rated power
    n/a (no PCS)
    Duration
    NA
    PCS included
    No
    Cooling
    Liquid
    Cell capacity
    NA
  • Rated energy
    NA
    Rated power
    50–60 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    NA
    Cell capacity
    100 Ah
  • Rated energy
    NA
    Rated power
    30 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    100 Ah
  • Rated energy
    NA
    Rated power
    60 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    100 Ah
  • Rated energy
    261.248 kWh
    Rated power
    125 kW
    Duration
    2.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Finike Lithium

    FL-ESS-261Announced

    261kWh Liquid-Cooled Energy Storage Cabinet

    Rated energy
    261 kWh
    Rated power
    NA
    Duration
    2 h
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    314 Ah

29 products

Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.

Browse BESS cabinets by size

Power × energy grid →

Each size has its own page with the products side by side.

BESS cabinet manufacturers for C&I sites in India20 companies in 11 cities, with profiles and websites.Companies →

New to BESS cabinets? What they are, and what each spec means

A cabinet BESS is a self-contained battery unit, usually from about 50 kWh to a few hundred kWh per cabinet, that sits outside or inside a factory, office, hospital or telecom site. It is the most common form of storage for commercial and industrial (C&I) sites cutting peak demand, reducing diesel use or riding through outages.

What each spec means

Rated energy(kWh)
How much electricity it stores when full. A 261 kWh cabinet can supply 125 kW for about 2 hours. Size it against the hours of backup you need, or the load you want to shift.
Rated power(kW)
The most it can charge or discharge at once. It has to cover the load you want to run from the battery. NA usually means a battery-only block, sold without its inverter (PCS).
Duration(h)
How many hours the system can deliver its rated power from full. Worked out by us, not printed by the maker: rated energy ÷ rated power, or 1 ÷ the printed charge/discharge rate (0.5P = 2 h). Shown only when the sheet prints one energy and one power figure, or a rate.
PCS included
The PCS is the battery's inverter: it turns the battery's DC into the AC your site uses. "No" means a battery-only block, and the PCS is bought and wired separately.
Cooling
How the cells are kept at the right temperature. Liquid cooling keeps cells more even and suits hot sites and heavy daily use; air cooling is simpler and common in smaller systems.
Cell capacity(Ah)
The size of each battery cell. 280 and 314 Ah are today's mainstream; cells of 500 Ah and more are newer. It tells you the cell generation, not how good the system is.
Charge/discharge rate(P)
How fast a battery charges or discharges compared with its size. 0.5P means full power is half the energy rating: 5000 kWh at 0.5P gives 2500 kW, for about 2 hours. 1P empties in about 1 hour.
Chemistry
The battery type. LFP (lithium iron phosphate) is the standard for stationary storage: it handles heat better and lasts longer than NMC.
DC voltage range(V)
The battery's voltage from empty to full. The PCS must work across this window, which matters when the battery and the PCS come from different makers.
AC voltage(V)
The voltage at the system's AC output. If it differs from your site's (415 V in most buildings), a transformer goes in between.
AC frequency(Hz)
India's grid runs at 50 Hz. A model listed only at 60 Hz is a variant for other markets.
Round-trip efficiency(%)
The share of energy you get back out of what you put in: 90% means 10 kWh lost per 100 kWh stored. Check what it is measured on (DC side or AC system); makers differ.
Efficiency measured
Where the efficiency was measured. A DC-side figure leaves out the inverter's losses, so it looks higher than an AC figure. Compare like with like.
Cycle life(cycles)
How much of the battery's capacity a cycle uses. Cycle-life claims depend on it: 6000 cycles at 80% DoD is not the same as at 100%.
Size (mm)
Outside size. Leave room around it for the doors to open, for air to flow and for service access.
Weight(kg)
An outdoor cabinet of about 250 kWh weighs 2 to 3 tonnes, so check the plinth or the floor it stands on.
Enclosure rating
How well the enclosure keeps out dust and water. IP54 or IP55 is usual outdoors; a higher second digit means better protection against water.
Operating temperature(°C)
The outdoor temperatures it is built to run in. Check the top end against your site's summer peak; output can be limited near the limit.
Max altitude(m)
Thin air cools less well. Above this height the output is reduced, or the warranty may not apply.
Noise at 1 m(dB(A))
How loud it is one metre away, mostly from the cooling fans. It matters near offices, homes and the site boundary.
Fire suppression
What the system does if a cell overheats: gas or aerosol to put out a fire, and vents or panels to let explosive gas out safely.
Certifications
The safety and grid standards it is tested to. IEC 62619 covers battery safety, UL 1973 stationary batteries, and UL 9540A is a test of how a fire spreads between cells and racks.

NA in the table means the maker doesn't publish that figure. It is worth asking them for it.

What to compare before you choose

  • Usable energy and power per cabinet, and how many cabinets can run in parallel.
  • Whether the PCS is built into the cabinet or supplied separately, and if it can run off-grid (grid-forming) during an outage.
  • Cooling, ingress protection (IP rating) and the ambient temperature range it is rated for.
  • Fire safety design and certifications, including what is inside the cabinet to detect and suppress a fault.
  • Warranty terms in years and throughput, and who services it in your region.
  • Whether the battery and inverter data are available over Modbus or a similar open protocol, so any EMS or SCADA can read them.

29 products from 16 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.