Listed A–Z, not ranked · Reviewed November 2026
BESS cabinets products
- Rated energy
- 261 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 64–480 kWh
- Rated power
- 30–250 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- 314 Ah
- Rated energy
- NA
- Rated power
- 100 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- NA
- Rated energy
- 215 kWh
- Rated power
- 100 kW
- Duration
- 2.2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 464 kWh
- Rated power
- 250 kW
- Duration
- 1.9 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 261 kWh
- Rated power
- 125 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 261 kWh
- Rated power
- 125 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 241 kWh
- Rated power
- n/a (no PCS)
- Duration
- NA
- PCS included
- No
- Cooling
- Air
- Cell capacity
- 314 Ah
- Rated energy
- 51.2–256 kWh
- Rated power
- 25–125 kW
- Duration
- NA
- PCS included
- NA
- Cooling
- Air
- Cell capacity
- NA
- Rated energy
- 89–220 kWh
- Rated power
- n/a (no PCS)
- Duration
- NA
- PCS included
- No
- Cooling
- Air
- Cell capacity
- NA
- Rated energy
- 315.3–946.2 kWh
- Rated power
- 100–250 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- 280 Ah
- Rated energy
- 261 kWh
- Rated power
- 125 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 50–200 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 100–300 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 160.77–261.25 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Air
- Cell capacity
- 314 Ah
- Rated energy
- 250 kWh
- Rated power
- 125 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 233 kWh
- Rated power
- 125 kW
- Duration
- 1.9 h
- PCS included
- NA
- Cooling
- Air
- Cell capacity
- NA
- Rated energy
- from 261 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 100–225 kWh
- Rated power
- 50–100 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- 314 Ah
- Rated energy
- 215 kWh
- Rated power
- 100 kW
- Duration
- 2.2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 261 kWh
- Rated power
- 125 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 257 kWh
- Rated power
- 125 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 514 kWh
- Rated power
- 125 kW
- Duration
- 4.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- NA
- Rated power
- n/a (no PCS)
- Duration
- NA
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- NA
- Rated power
- 50–60 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- 100 Ah
- Rated energy
- NA
- Rated power
- 30 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- 100 Ah
- Rated energy
- NA
- Rated power
- 60 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- 100 Ah
- Rated energy
- 261.248 kWh
- Rated power
- 125 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 261 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
| Details | PCS included | Add to plan, favourite | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Ashbee Energy Systems | Magnum 261 kWhAll In One Liquid Cooling Energy Storage System | 261 kWh | NA | 2 h | Yes | Liquid | 314 Ah | ||
| CLN Energy | All-in-One Pro Series | 64–480 kWh | 30–250 kW | NA | Yes | Air | 314 Ah | ||
| CLN Energy | CLNCIA 100kW/200kWhAir-cooled | NA | 100 kW | 2 h | Yes | Air | NA | ||
| CLN Energy | CLNCIL 100kW/215kWhLiquid-cooled | 215 kWh | 100 kW | 2.2 h | Yes | Liquid | NA | ||
| CLN Energy | CLNCIL 250kW/464kWhLiquid-cooled | 464 kWh | 250 kW | 1.9 h | Yes | Liquid | NA | ||
| Cygni Energy | 125kW/261kWh CabinetPower Stack | 261 kWh | 125 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| Cygni Energy | 125kW/261kWh Hybrid Cabinet | 261 kWh | 125 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| Cygni Energy | 241kWh Air Cooled Battery PackBattery cabinet, no PCS | 241 kWh | n/a (no PCS) | NA | No | Air | 314 Ah | ||
| Cygni Energy | CYG-HVPCCygni 51.2kWh Solution: 512 V LFP floor-rack battery, 51.2 to 256 kWh | 51.2–256 kWh | 25–125 kW | NA | NA | Air | NA | ||
| Delta Electronics India | Li-ion Battery Energy Storage Cabinet | 89–220 kWh | n/a (no PCS) | NA | No | Air | NA | ||
| Delta Electronics India | SK-Series Energy Storage SkidLFP Battery Energy Storage Solutions | 315.3–946.2 kWh | 100–250 kW | NA | Yes | Air | 280 Ah | ||
| Electres | Electres Pro125 kW / 261 kWh Liquid-Cooled All-in-One BESS | 261 kWh | 125 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| EnerCube | All-in-one Hybrid Compact System | 50–200 kWh | NA | NA | Yes | NA | NA | ||
| EnerCube | Plug & Play Storage Cabinet | 100–300 kWh | NA | NA | Yes | NA | NA | ||
| Exicom | Energy Qb Grid Core 261 | 160.77–261.25 kWh | n/a (no PCS) | 2 h | No | Air | 314 Ah | ||
| GoodEnough Energy | StorEDGE 0.25 | 250 kWh | 125 kW | 2 h | Yes | NA | NA | ||
| Hanum Energy | Cabinet 125 | 233 kWh | 125 kW | 1.9 h | NA | Air | NA | ||
| Ornate Solar | UnityESS Aqua | from 261 kWh | NA | NA | Yes | Liquid | 314 Ah | ||
| Ornate Solar | UnityESS Aura | 100–225 kWh | 50–100 kW | NA | Yes | Air | 314 Ah | ||
| ST Energy | Day | 215 kWh | 100 kW | 2.2 h | Yes | Liquid | 314 Ah | ||
| Statcon Energiaa | SE-BESS 261 | 261 kWh | 125 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| Sungrow | PowerStack 255CSLiquid Cooled C&I Energy Storage System | 257 kWh | 125 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| Sungrow | PowerStack 255CS 125kW/514kWhLiquid Cooled C&I Energy Storage System | 514 kWh | 125 kW | 4.1 h | Yes | Liquid | 314 Ah | ||
| Sungrow | ST688UX-ALPowerStack Liquid Cooling Supplemental Cabinet | NA | n/a (no PCS) | NA | No | Liquid | NA | ||
| Tobor | MTX Hybrid 50 / 60 | NA | 50–60 kW | NA | Yes | NA | 100 Ah | ||
| Tobor | MTX Standard 30 | NA | 30 kW | NA | Yes | Air | 100 Ah | ||
| Tobor | MTX Standard 60 | NA | 60 kW | NA | Yes | Air | 100 Ah | ||
| Vikram Solar | PowerHive P261 | 261.248 kWh | 125 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| Finike Lithium | FL-ESS-261Announced261kWh Liquid-Cooled Energy Storage Cabinet | 261 kWh | NA | 2 h | NA | Liquid | 314 Ah |
29 products
Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.
Browse BESS cabinets by size
Power × energy grid →Each size has its own page with the products side by side.
Is your company on this list? Add it, update your details or raise a concern →
New to BESS cabinets? What they are, and what each spec means
A cabinet BESS is a self-contained battery unit, usually from about 50 kWh to a few hundred kWh per cabinet, that sits outside or inside a factory, office, hospital or telecom site. It is the most common form of storage for commercial and industrial (C&I) sites cutting peak demand, reducing diesel use or riding through outages.
What each spec means
- Rated energy(kWh)
- How much electricity it stores when full. A 261 kWh cabinet can supply 125 kW for about 2 hours. Size it against the hours of backup you need, or the load you want to shift.
- Rated power(kW)
- The most it can charge or discharge at once. It has to cover the load you want to run from the battery. NA usually means a battery-only block, sold without its inverter (PCS).
- Duration(h)
- How many hours the system can deliver its rated power from full. Worked out by us, not printed by the maker: rated energy ÷ rated power, or 1 ÷ the printed charge/discharge rate (0.5P = 2 h). Shown only when the sheet prints one energy and one power figure, or a rate.
- PCS included
- The PCS is the battery's inverter: it turns the battery's DC into the AC your site uses. "No" means a battery-only block, and the PCS is bought and wired separately.
- Cooling
- How the cells are kept at the right temperature. Liquid cooling keeps cells more even and suits hot sites and heavy daily use; air cooling is simpler and common in smaller systems.
- Cell capacity(Ah)
- The size of each battery cell. 280 and 314 Ah are today's mainstream; cells of 500 Ah and more are newer. It tells you the cell generation, not how good the system is.
- Charge/discharge rate(P)
- How fast a battery charges or discharges compared with its size. 0.5P means full power is half the energy rating: 5000 kWh at 0.5P gives 2500 kW, for about 2 hours. 1P empties in about 1 hour.
- Chemistry
- The battery type. LFP (lithium iron phosphate) is the standard for stationary storage: it handles heat better and lasts longer than NMC.
- DC voltage range(V)
- The battery's voltage from empty to full. The PCS must work across this window, which matters when the battery and the PCS come from different makers.
- AC voltage(V)
- The voltage at the system's AC output. If it differs from your site's (415 V in most buildings), a transformer goes in between.
- AC frequency(Hz)
- India's grid runs at 50 Hz. A model listed only at 60 Hz is a variant for other markets.
- Round-trip efficiency(%)
- The share of energy you get back out of what you put in: 90% means 10 kWh lost per 100 kWh stored. Check what it is measured on (DC side or AC system); makers differ.
- Efficiency measured
- Where the efficiency was measured. A DC-side figure leaves out the inverter's losses, so it looks higher than an AC figure. Compare like with like.
- Cycle life(cycles)
- How much of the battery's capacity a cycle uses. Cycle-life claims depend on it: 6000 cycles at 80% DoD is not the same as at 100%.
- Size (mm)
- Outside size. Leave room around it for the doors to open, for air to flow and for service access.
- Weight(kg)
- An outdoor cabinet of about 250 kWh weighs 2 to 3 tonnes, so check the plinth or the floor it stands on.
- Enclosure rating
- How well the enclosure keeps out dust and water. IP54 or IP55 is usual outdoors; a higher second digit means better protection against water.
- Operating temperature(°C)
- The outdoor temperatures it is built to run in. Check the top end against your site's summer peak; output can be limited near the limit.
- Max altitude(m)
- Thin air cools less well. Above this height the output is reduced, or the warranty may not apply.
- Noise at 1 m(dB(A))
- How loud it is one metre away, mostly from the cooling fans. It matters near offices, homes and the site boundary.
- Fire suppression
- What the system does if a cell overheats: gas or aerosol to put out a fire, and vents or panels to let explosive gas out safely.
- Certifications
- The safety and grid standards it is tested to. IEC 62619 covers battery safety, UL 1973 stationary batteries, and UL 9540A is a test of how a fire spreads between cells and racks.
NA in the table means the maker doesn't publish that figure. It is worth asking them for it.
What to compare before you choose
- Usable energy and power per cabinet, and how many cabinets can run in parallel.
- Whether the PCS is built into the cabinet or supplied separately, and if it can run off-grid (grid-forming) during an outage.
- Cooling, ingress protection (IP rating) and the ambient temperature range it is rated for.
- Fire safety design and certifications, including what is inside the cabinet to detect and suppress a fault.
- Warranty terms in years and throughput, and who services it in your region.
- Whether the battery and inverter data are available over Modbus or a similar open protocol, so any EMS or SCADA can read them.
29 products from 16 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.