Container BESS products in India

Listed A–Z, not ranked · Reviewed November 2026

BESS containers products

  • Ashbee Energy Systems

    Magnum 1 MW / 2 MWh

    Solar and GEN BESS, Container >1MWh

    Rated energy
    2000 kWh
    Rated power
    1000 kW
    Duration
    2 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    NA
  • Ashbee Energy Systems

    Magnum 5 MWh

    Liquid Cooling Energy Storage Outdoor Cabinet

    Rated energy
    5015 kWh
    Rated power
    NA
    Duration
    2 h
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Ashbee Energy Systems

    Magnum 500 kW / 1 MWh

    Solar & GEN BESS, Container <1MWh

    Rated energy
    1000 kWh
    Rated power
    500 kW
    Duration
    2 h
    PCS included
    Yes
    Cooling
    NA
    Cell capacity
    NA
  • Rated energy
    1045 kWh
    Rated power
    NA
    Duration
    2 h
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    2073 kWh
    Rated power
    1200 kW
    Duration
    1.7 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    100 Ah
  • Rated energy
    3340 kWh
    Rated power
    1600 kW
    Duration
    2.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • CLN Energy

    5 MWh BESS Solution

    Containerised 5.015 MWh BESS

    Rated energy
    5015 kWh
    Rated power
    NA
    Duration
    2 h
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Cummins India

    Cummins BESS

    10-ft and 20-ft high cube containers, 211–2280 kWh

    Rated energy
    211–2280 kWh
    Rated power
    NA
    Duration
    2 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    300 Ah
  • Rated energy
    5016 kWh
    Rated power
    n/a (no PCS)
    Duration
    2 h
    PCS included
    No
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    6250 kWh
    Rated power
    n/a (no PCS)
    Duration
    2 h
    PCS included
    No
    Cooling
    Liquid
    Cell capacity
    587 Ah
  • Rated energy
    2500–5000 kWh
    Rated power
    1250–2500 kW
    Duration
    NA
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    NA
  • Rated energy
    300–5015 kWh
    Rated power
    150–5500 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    NA
    Cell capacity
    NA
  • Rated energy
    1044 kWh
    Rated power
    500 kW
    Duration
    2.1 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    5000 kWh
    Rated power
    n/a (no PCS)
    Duration
    2 h
    PCS included
    No
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    5000 kWh
    Rated power
    2500 kW
    Duration
    2 h
    PCS included
    Yes
    Cooling
    NA
    Cell capacity
    NA
  • Rated energy
    5000 kWh
    Rated power
    2500 kW
    Duration
    2 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    NA
  • Jupiter Electric Mobility

    250KW/482kWh

    DG Reduction Air Cooled Series BESS System

    Rated energy
    482 kWh
    Rated power
    250 kW
    Duration
    1.9 h
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    NA
  • Rated energy
    723 kWh
    Rated power
    250 kW
    Duration
    2.9 h
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    NA
  • Jupiter Electric Mobility

    600KW/747kWh

    Air Cooled BESS System, UPS Application

    Rated energy
    747 kWh
    Rated power
    600 kW
    Duration
    1.2 h
    PCS included
    NA
    Cooling
    Air
    Cell capacity
    304 Ah
  • Rated energy
    3000–6250 kWh
    Rated power
    2500 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    NA
  • REPLUS Engitech

    RE5K

    5.01 MWh Liquid-Cooled BESS

    Rated energy
    5010 kWh
    Rated power
    1250–2500 kW
    Duration
    NA
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Rated energy
    5015.9–6025 kWh
    Rated power
    2500 kW
    Duration
    2 h
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    NA
  • Statcon Energiaa

    GAJ X

    Containerised solar BESS

    Rated energy
    96–288 kWh
    Rated power
    50–200 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    Air
    Cell capacity
    NA
  • Rated energy
    500–5000 kWh
    Rated power
    NA
    Duration
    NA
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    NA
  • Sungrow

    PowerTitan 1-hour application

    Liquid Cooling Energy Storage System

    Rated energy
    NA
    Rated power
    NA
    Duration
    NA
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    NA
  • Sungrow

    PowerTitan 2-hour application

    Liquid Cooling Energy Storage System, ST2752UX-US × 4 with SC5000UD-MV-US

    Rated energy
    11008 kWh
    Rated power
    NA
    Duration
    NA
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    NA
  • Sungrow

    PowerTitan 2.0

    Liquid Cooled Energy Storage System

    Rated energy
    5015 kWh
    Rated power
    1260–2520 kW
    Duration
    NA
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Tobor

    CTX-5000

    CTX 2.5 MW

    Rated energy
    5064 kWh
    Rated power
    2500 kW
    Duration
    2 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • Tobor

    CTX-6600

    CTX 6.6 MWh

    Rated energy
    6638 kWh
    Rated power
    1750 kW
    Duration
    3.8 h
    PCS included
    Yes
    Cooling
    Liquid
    Cell capacity
    588 Ah
  • Tobor

    CTX-B20

    CTX Block 10 MW

    Rated energy
    20257 kWh
    Rated power
    10000 kW
    Duration
    2 h
    PCS included
    Yes
    Cooling
    NA
    Cell capacity
    NA
  • Rated energy
    5015 kWh
    Rated power
    NA
    Duration
    NA
    PCS included
    NA
    Cooling
    Liquid
    Cell capacity
    314 Ah
  • HBL Engineering

    GSESSLegacy

    Grid Scale Energy Storage System

    Rated energy
    240–1008 kWh
    Rated power
    250–1000 kW
    Duration
    NA
    PCS included
    NA
    Cooling
    NA
    Cell capacity
    NA

32 products

Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.

Browse BESS containers by size

Power × energy grid →

Each size has its own page with the products side by side.

BESS container manufacturers and integrators in India25 companies in 13 cities, with profiles and websites.Companies →

New to BESS containers? What they are, and what each spec means

A container BESS packs battery racks, a battery management system, cooling and fire protection into a shipping-container-sized enclosure, usually holding several megawatt-hours. These are the systems behind grid-scale storage tenders, solar-plus-storage plants and large industrial sites. The companies below build or integrate them for the Indian market.

What each spec means

Rated energy(kWh)
How much electricity it stores when full. A 1000 kWh system can supply 250 kW for about 4 hours. Size it against the hours of backup you need, or the load you want to shift.
Rated power(kW)
The most it can charge or discharge at once. It has to cover the load you want to run from the battery. NA usually means a battery-only block, sold without its inverter (PCS).
Duration(h)
How many hours the system can deliver its rated power from full. Worked out by us, not printed by the maker: rated energy ÷ rated power, or 1 ÷ the printed charge/discharge rate (0.5P = 2 h). Shown only when the sheet prints one energy and one power figure, or a rate.
PCS included
The PCS is the battery's inverter: it turns the battery's DC into the AC your site uses. "No" means a battery-only block, and the PCS is bought and wired separately.
Cooling
How the cells are kept at the right temperature. Liquid cooling keeps cells more even and suits hot sites and heavy daily use; air cooling is simpler and common in smaller systems.
Cell capacity(Ah)
The size of each battery cell. 280 and 314 Ah are today's mainstream; cells of 500 Ah and more are newer. It tells you the cell generation, not how good the system is.
Charge/discharge rate(P)
How fast a battery charges or discharges compared with its size. 0.5P means full power is half the energy rating: 5000 kWh at 0.5P gives 2500 kW, for about 2 hours. 1P empties in about 1 hour.
Chemistry
The battery type. LFP (lithium iron phosphate) is the standard for stationary storage: it handles heat better and lasts longer than NMC.
DC voltage range(V)
The battery's voltage from empty to full. The PCS must work across this window, which matters when the battery and the PCS come from different makers.
AC voltage(V)
The voltage at the system's AC output. If it differs from your site's (415 V in most buildings), a transformer goes in between.
AC frequency(Hz)
India's grid runs at 50 Hz. A model listed only at 60 Hz is a variant for other markets.
Round-trip efficiency(%)
The share of energy you get back out of what you put in: 90% means 10 kWh lost per 100 kWh stored. Check what it is measured on (DC side or AC system); makers differ.
Efficiency measured
Where the efficiency was measured. A DC-side figure leaves out the inverter's losses, so it looks higher than an AC figure. Compare like with like.
Cycle life(cycles)
How much of the battery's capacity a cycle uses. Cycle-life claims depend on it: 6000 cycles at 80% DoD is not the same as at 100%.
Size (mm)
Outside size. A 20-ft container is about 6058 × 2438 × 2896 mm. Leave room for the doors to open and for a crane or truck to place it.
Weight(kg)
A full 20-ft, 5 MWh container weighs roughly 40 tonnes, so the foundation and the crane are part of the job.
Enclosure rating
How well the enclosure keeps out dust and water. IP54 or IP55 is usual outdoors; a higher second digit means better protection against water.
Operating temperature(°C)
The outdoor temperatures it is built to run in. Check the top end against your site's summer peak; output can be limited near the limit.
Max altitude(m)
Thin air cools less well. Above this height the output is reduced, or the warranty may not apply.
Fire suppression
What the system does if a cell overheats: gas or aerosol to put out a fire, and vents or panels to let explosive gas out safely.
Certifications
The safety and grid standards it is tested to. IEC 62619 covers battery safety, UL 1973 stationary batteries, and UL 9540A is a test of how a fire spreads between cells and racks.

NA in the table means the maker doesn't publish that figure. It is worth asking them for it.

What to compare before you choose

  • Cell chemistry and cell supplier (most containers today use LFP), and whether the cells are made in India.
  • Usable energy per container, round-trip efficiency at the point of connection, and the warranted cycles and end-of-life capacity.
  • Cooling method (air or liquid) and how it copes with Indian summer ambient temperatures.
  • Fire safety design and certifications such as UL 9540A test data, and what the container does on an off-gas alarm.
  • Who supplies the PCS and the plant controller, and whether the BMS exposes its data over an open protocol.
  • Service presence in India: spares, response time and who commissions the system.

32 products from 18 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.

Not sure what to buy? Ask us what's compatible and what size fits your site.