Listed A–Z, not ranked · Reviewed November 2026
BESS containers products
- Rated energy
- 2000 kWh
- Rated power
- 1000 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 5015 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 1000 kWh
- Rated power
- 500 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 1045 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 2073 kWh
- Rated power
- 1200 kW
- Duration
- 1.7 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 100 Ah
- Rated energy
- 3340 kWh
- Rated power
- 1600 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5015 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 211–2280 kWh
- Rated power
- NA
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 300 Ah
- Rated energy
- 5016 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 6250 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 587 Ah
- Rated energy
- 2500–5000 kWh
- Rated power
- 1250–2500 kW
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 300–5015 kWh
- Rated power
- 150–5500 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 1044 kWh
- Rated power
- 500 kW
- Duration
- 2.1 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5000 kWh
- Rated power
- n/a (no PCS)
- Duration
- 2 h
- PCS included
- No
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5000 kWh
- Rated power
- 2500 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 5000 kWh
- Rated power
- 2500 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 482 kWh
- Rated power
- 250 kW
- Duration
- 1.9 h
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- NA
- Rated energy
- 723 kWh
- Rated power
- 250 kW
- Duration
- 2.9 h
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- NA
- Rated energy
- 747 kWh
- Rated power
- 600 kW
- Duration
- 1.2 h
- PCS included
- NA
- Cooling
- Air
- Cell capacity
- 304 Ah
- Rated energy
- 3000–6250 kWh
- Rated power
- 2500 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 5010 kWh
- Rated power
- 1250–2500 kW
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5015.9–6025 kWh
- Rated power
- 2500 kW
- Duration
- 2 h
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 96–288 kWh
- Rated power
- 50–200 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Air
- Cell capacity
- NA
- Rated energy
- 500–5000 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- NA
- Rated power
- NA
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- NA
Liquid Cooling Energy Storage System, ST2752UX-US × 4 with SC5000UD-MV-US
- Rated energy
- 11008 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- NA
- Rated energy
- 5015 kWh
- Rated power
- 1260–2520 kW
- Duration
- NA
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 5064 kWh
- Rated power
- 2500 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 6638 kWh
- Rated power
- 1750 kW
- Duration
- 3.8 h
- PCS included
- Yes
- Cooling
- Liquid
- Cell capacity
- 588 Ah
- Rated energy
- 20257 kWh
- Rated power
- 10000 kW
- Duration
- 2 h
- PCS included
- Yes
- Cooling
- NA
- Cell capacity
- NA
- Rated energy
- 5015 kWh
- Rated power
- NA
- Duration
- NA
- PCS included
- NA
- Cooling
- Liquid
- Cell capacity
- 314 Ah
- Rated energy
- 240–1008 kWh
- Rated power
- 250–1000 kW
- Duration
- NA
- PCS included
- NA
- Cooling
- NA
- Cell capacity
- NA
| Details | PCS included | Add to plan, favourite | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Ashbee Energy Systems | Magnum 1 MW / 2 MWhSolar and GEN BESS, Container >1MWh | 2000 kWh | 1000 kW | 2 h | Yes | Liquid | NA | ||
| Ashbee Energy Systems | Magnum 5 MWhLiquid Cooling Energy Storage Outdoor Cabinet | 5015 kWh | NA | 2 h | NA | Liquid | 314 Ah | ||
| Ashbee Energy Systems | Magnum 500 kW / 1 MWhSolar & GEN BESS, Container <1MWh | 1000 kWh | 500 kW | 2 h | Yes | NA | NA | ||
| CLN Energy | 1 MWh BESS Solution | 1045 kWh | NA | 2 h | NA | Liquid | 314 Ah | ||
| CLN Energy | 2 MWh BESS Solution | 2073 kWh | 1200 kW | 1.7 h | Yes | Liquid | 100 Ah | ||
| CLN Energy | 3 MWh BESS Solution | 3340 kWh | 1600 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| CLN Energy | 5 MWh BESS SolutionContainerised 5.015 MWh BESS | 5015 kWh | NA | 2 h | NA | Liquid | 314 Ah | ||
| Cummins India | Cummins BESS10-ft and 20-ft high cube containers, 211–2280 kWh | 211–2280 kWh | NA | 2 h | Yes | Liquid | 300 Ah | ||
| Cygni Energy | Cygni Max5MWh DC Block | 5016 kWh | n/a (no PCS) | 2 h | No | Liquid | 314 Ah | ||
| Cygni Energy | Cygni Ultra Max6.25MWh DC Block | 6250 kWh | n/a (no PCS) | 2 h | No | Liquid | 587 Ah | ||
| Cygni Energy | Flex Stack | 2500–5000 kWh | 1250–2500 kW | NA | NA | Liquid | NA | ||
| Delta Electronics India | Battery Energy Storage System | 300–5015 kWh | 150–5500 kW | NA | Yes | NA | NA | ||
| Enerveda Vault | CORE 1044 | 1044 kWh | 500 kW | 2.1 h | Yes | Liquid | 314 Ah | ||
| Enerveda Vault | TITAN 5000 | 5000 kWh | n/a (no PCS) | 2 h | No | Liquid | 314 Ah | ||
| GoodEnough Energy | StorEDGE 5.0 | 5000 kWh | 2500 kW | 2 h | Yes | NA | NA | ||
| Hanum Energy | Container 5000 | 5000 kWh | 2500 kW | 2 h | Yes | Liquid | NA | ||
| Jupiter Electric Mobility | 250KW/482kWhDG Reduction Air Cooled Series BESS System | 482 kWh | 250 kW | 1.9 h | Yes | Air | NA | ||
| Jupiter Electric Mobility | 250KW/723kWhAir Cooled BESS System | 723 kWh | 250 kW | 2.9 h | Yes | Air | NA | ||
| Jupiter Electric Mobility | 600KW/747kWhAir Cooled BESS System, UPS Application | 747 kWh | 600 kW | 1.2 h | NA | Air | 304 Ah | ||
| Ornate Solar | UnityESS Ultima | 3000–6250 kWh | 2500 kW | NA | Yes | Liquid | NA | ||
| REPLUS Engitech | RE5K5.01 MWh Liquid-Cooled BESS | 5010 kWh | 1250–2500 kW | NA | NA | Liquid | 314 Ah | ||
| ST Energy | Dusk | 5015.9–6025 kWh | 2500 kW | 2 h | NA | Liquid | NA | ||
| Statcon Energiaa | GAJ XContainerised solar BESS | 96–288 kWh | 50–200 kW | NA | Yes | Air | NA | ||
| StorageX | StorageX Vault Grid | 500–5000 kWh | NA | NA | NA | Liquid | NA | ||
| Sungrow | PowerTitan 1-hour applicationLiquid Cooling Energy Storage System | NA | NA | NA | NA | Liquid | NA | ||
| Sungrow | PowerTitan 2-hour applicationLiquid Cooling Energy Storage System, ST2752UX-US × 4 with SC5000UD-MV-US | 11008 kWh | NA | NA | Yes | Liquid | NA | ||
| Sungrow | PowerTitan 2.0Liquid Cooled Energy Storage System | 5015 kWh | 1260–2520 kW | NA | Yes | Liquid | 314 Ah | ||
| Tobor | CTX-5000CTX 2.5 MW | 5064 kWh | 2500 kW | 2 h | Yes | Liquid | 314 Ah | ||
| Tobor | CTX-6600CTX 6.6 MWh | 6638 kWh | 1750 kW | 3.8 h | Yes | Liquid | 588 Ah | ||
| Tobor | CTX-B20CTX Block 10 MW | 20257 kWh | 10000 kW | 2 h | Yes | NA | NA | ||
| Waaree Energies | Utility Energy Storage Solution5MWhr 20Ft | 5015 kWh | NA | NA | NA | Liquid | 314 Ah | ||
| HBL Engineering | GSESSLegacyGrid Scale Energy Storage System | 240–1008 kWh | 250–1000 kW | NA | NA | NA | NA |
32 products
Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.
Browse BESS containers by size
Power × energy grid →Each size has its own page with the products side by side.
Is your company on this list? Add it, update your details or raise a concern →
New to BESS containers? What they are, and what each spec means
A container BESS packs battery racks, a battery management system, cooling and fire protection into a shipping-container-sized enclosure, usually holding several megawatt-hours. These are the systems behind grid-scale storage tenders, solar-plus-storage plants and large industrial sites. The companies below build or integrate them for the Indian market.
What each spec means
- Rated energy(kWh)
- How much electricity it stores when full. A 1000 kWh system can supply 250 kW for about 4 hours. Size it against the hours of backup you need, or the load you want to shift.
- Rated power(kW)
- The most it can charge or discharge at once. It has to cover the load you want to run from the battery. NA usually means a battery-only block, sold without its inverter (PCS).
- Duration(h)
- How many hours the system can deliver its rated power from full. Worked out by us, not printed by the maker: rated energy ÷ rated power, or 1 ÷ the printed charge/discharge rate (0.5P = 2 h). Shown only when the sheet prints one energy and one power figure, or a rate.
- PCS included
- The PCS is the battery's inverter: it turns the battery's DC into the AC your site uses. "No" means a battery-only block, and the PCS is bought and wired separately.
- Cooling
- How the cells are kept at the right temperature. Liquid cooling keeps cells more even and suits hot sites and heavy daily use; air cooling is simpler and common in smaller systems.
- Cell capacity(Ah)
- The size of each battery cell. 280 and 314 Ah are today's mainstream; cells of 500 Ah and more are newer. It tells you the cell generation, not how good the system is.
- Charge/discharge rate(P)
- How fast a battery charges or discharges compared with its size. 0.5P means full power is half the energy rating: 5000 kWh at 0.5P gives 2500 kW, for about 2 hours. 1P empties in about 1 hour.
- Chemistry
- The battery type. LFP (lithium iron phosphate) is the standard for stationary storage: it handles heat better and lasts longer than NMC.
- DC voltage range(V)
- The battery's voltage from empty to full. The PCS must work across this window, which matters when the battery and the PCS come from different makers.
- AC voltage(V)
- The voltage at the system's AC output. If it differs from your site's (415 V in most buildings), a transformer goes in between.
- AC frequency(Hz)
- India's grid runs at 50 Hz. A model listed only at 60 Hz is a variant for other markets.
- Round-trip efficiency(%)
- The share of energy you get back out of what you put in: 90% means 10 kWh lost per 100 kWh stored. Check what it is measured on (DC side or AC system); makers differ.
- Efficiency measured
- Where the efficiency was measured. A DC-side figure leaves out the inverter's losses, so it looks higher than an AC figure. Compare like with like.
- Cycle life(cycles)
- How much of the battery's capacity a cycle uses. Cycle-life claims depend on it: 6000 cycles at 80% DoD is not the same as at 100%.
- Size (mm)
- Outside size. A 20-ft container is about 6058 × 2438 × 2896 mm. Leave room for the doors to open and for a crane or truck to place it.
- Weight(kg)
- A full 20-ft, 5 MWh container weighs roughly 40 tonnes, so the foundation and the crane are part of the job.
- Enclosure rating
- How well the enclosure keeps out dust and water. IP54 or IP55 is usual outdoors; a higher second digit means better protection against water.
- Operating temperature(°C)
- The outdoor temperatures it is built to run in. Check the top end against your site's summer peak; output can be limited near the limit.
- Max altitude(m)
- Thin air cools less well. Above this height the output is reduced, or the warranty may not apply.
- Fire suppression
- What the system does if a cell overheats: gas or aerosol to put out a fire, and vents or panels to let explosive gas out safely.
- Certifications
- The safety and grid standards it is tested to. IEC 62619 covers battery safety, UL 1973 stationary batteries, and UL 9540A is a test of how a fire spreads between cells and racks.
NA in the table means the maker doesn't publish that figure. It is worth asking them for it.
What to compare before you choose
- Cell chemistry and cell supplier (most containers today use LFP), and whether the cells are made in India.
- Usable energy per container, round-trip efficiency at the point of connection, and the warranted cycles and end-of-life capacity.
- Cooling method (air or liquid) and how it copes with Indian summer ambient temperatures.
- Fire safety design and certifications such as UL 9540A test data, and what the container does on an off-gas alarm.
- Who supplies the PCS and the plant controller, and whether the BMS exposes its data over an open protocol.
- Service presence in India: spares, response time and who commissions the system.
32 products from 18 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.