AC side
- Rated power
- 1525–4390 kW
- Printed ratings
- 1525, 1590, 1685, 1910, 1955, 2005, 2055, 2100, 2195, 2290, 2385, 2530, 2865, 2935, 3005, 3055, 3080, 3150, 3180, 3290, 3370, 3820, 3915, 4010, 4105, 4200, 4390 kW
- Nominal AC voltage
- 480–690 V
- Grid frequency
- 50/60
DC side
- DC voltage range
- 679–1500 V
- Max DC current
- 4590 A
Performance
- Max efficiency
- 98.95 %
Build
- Type
- NA
- Cooling
- Air
- Ingress protection
- NEMA 3R / IP55
- Operating temperature
- -40–60 °C
- Weight
- 3900–4700 kg
- MV transformer built in
- No
- Communication
- Modbus TCP
Grid functions
- Off-grid / black start
- Not stated
- Grid-forming
- Not stated
Certification
- Certifications
- UL 1741, CSA 22.2 No.107.1-16, IEC 62109-1, IEC 62109-2, IEC 62477-1, IEEE 1547, UL 1741 SA & SB, IEC 62116
- Size:
- 22 sizes
- Model code:
- FP2195K, FP3290K, FP4390K, FP2101K, FP3151K, FP4200K, FP2055K, FP3080K, FP4105K, FP2005K, FP3005K, FP4010K, FP1955K, FP2935K, FP3915K, FP1910K, FP2865K, FP3820K, FP1685K, FP2530K, FP3370K, FP1590K, FP2385K, FP3180K, FP1525K, FP2290K, FP3055K
- Checked:
- November 2026, against the datasheet
Full datasheet
Every row the maker prints, copied as written, read 2026-11-15.
Overview
- Product
- Freemaq PCSK
- Models
- 690 V frame 2: FP2195K; 690 V frame 3: FP3290K; 690 V frame 4: FP4390K; 660 V frame 2: FP2101K; 660 V frame 3: FP3151K; 660 V frame 4: FP4200K; 645 V frame 2: FP2055K; 645 V frame 3: FP3080K; 645 V frame 4: FP4105K; 630 V frame 2: FP2005K; 630 V frame 3: FP3005K; 630 V frame 4: FP4010K; 615 V frame 2: FP1955K; 615 V frame 3: FP2935K; 615 V frame 4: FP3915K; 600 V frame 2: FP1910K; 600 V frame 3: FP2865K; 600 V frame 4: FP3820K; 530 V frame 2: FP1685K; 530 V frame 3: FP2530K; 530 V frame 4: FP3370K; 500 V frame 2: FP1590K; 500 V frame 3: FP2385K; 500 V frame 4: FP3180K; 480 V frame 2: FP1525K; 480 V frame 3: FP2290K; 480 V frame 4: FP3055K
- Description
- OUR PCSK are battery inverters for utility-scale applications.(power-electronics.com)The utility-scale battery inverters. From one independent BESS with PCSK to up to four independent BESS with Multi PCSK.(bucket-software00.s3.eu-west-1.amazonaws.com)
- Power range
- Up to 5360 kVA(power-electronics.com)
- Battery type
- All type of batteries (BMS required)
- Sheet version
- V. 1.4.5 20260828
DC side
- DC voltage range
- 690 V: 976 V - 1500 V; 660 V: 934 V - 1500 V; 645 V: 913 V - 1500 V; 630 V: 891 V - 1500 V; 615 V: 870 V - 1500 V; 600 V: 849 V - 1500 V; 530 V: 750 V - 1500 V; 500 V: 708 V - 1500 V; 480 V: 679 V - 1500 VUp to 1500 Vdc(power-electronics.com)
- Max. DC voltage
- 1500 V
- DC voltage windows
- Nine different DC voltage windows(power-electronics.com)
- Max. DC continuous current (A)
- Frame 2: 2295; Frame 3: 3443; Frame 4: 4590
- Max. DC short-circuit current
- 500 kA with a time constant of 1 ms
- DC voltage ripple
- <3%
AC side
- AC output power at 40 °C (kVA/kW)
- FP2195K: 2195; FP3290K: 3290; FP4390K: 4390; FP2101K: 2100; FP3151K: 3150; FP4200K: 4200; FP2055K: 2055; FP3080K: 3080; FP4105K: 4105; FP2005K: 2005; FP3005K: 3005; FP4010K: 4010; FP1955K: 1955; FP2935K: 2935; FP3915K: 3915; FP1910K: 1910; FP2865K: 2865; FP3820K: 3820; FP1685K: 1685; FP2530K: 2530; FP3370K: 3370; FP1590K: 1590; FP2385K: 2385; FP3180K: 3180; FP1525K: 1525; FP2290K: 2290; FP3055K: 3055
- AC output power at 50 °C (kVA/kW)
- FP2195K: 2035; FP3290K: 3055; FP4390K: 4075; FP2101K: 1950; FP3151K: 2925; FP4200K: 3900; FP2055K: 1905; FP3080K: 2855; FP4105K: 3810; FP2005K: 1860; FP3005K: 2790; FP4010K: 3720; FP1955K: 1815; FP2935K: 2725; FP3915K: 3635; FP1910K: 1775; FP2865K: 2660; FP3820K: 3545; FP1685K: 1565; FP2530K: 2350; FP3370K: 3130; FP1590K: 1475; FP2385K: 2215; FP3180K: 2955; FP1525K: 1415; FP2290K: 2125; FP3055K: 2840
- Nominal AC voltage (V)
- 690 V: 690 V ±10%; 660 V: 660 V ±10%; 645 V: 645 V ±10%; 630 V: 630 V ±10%; 615 V: 615 V ±10%; 600 V: 600 V ±10%; 530 V: 530 V ±10%; 500 V: 500 V ±10%; 480 V: 480V ±10%
- Grid frequency
- 50/60 Hz
- Max. AC output current at 40 °C (A)
- Frame 2: 1837; Frame 3: 2756; Frame 4: 3674
- Power factor
- 0.5 leading … 0.5 lagging
- Reactive power
- Four quadrant operation
- Current harmonic distortion (THDi)
- <3% per IEEE519
- Overload capability
- 166% - 100 ms / 150% - 5 s / 120% - 8 s / 110% - 15 s
Efficiency
- Max. efficiency
- FP2195K: 98.84%; FP3290K: 98.87%; FP4390K: 98.94%; FP2101K: 98.86%; FP3151K: 98.89%; FP4200K: 98.95%; FP2055K: 98.85%; FP3080K: 98.88%; FP4105K: 98.81%; FP2005K: 98.79%; FP3005K: 98.82%; FP4010K: 98.88%; FP1955K: 98.75%; FP2935K: 98.78%; FP3915K: 98.77%; FP1910K: 98.82%; FP2865K: 98.85%; FP3820K: 98.78%; 530 V (all frames): 98.78% (preliminary); 500 V (all frames): 98.78% (preliminary); 480 V (all frames): 98.78% (preliminary)
- European efficiency
- FP2195K: 98.34%; FP3290K: 98.49%; FP4390K: 98.51%; FP2101K: 98.36%; FP3151K: 98.51%; FP4200K: 98.53%; FP2055K: 98.24%; FP3080K: 98.39%; FP4105K: 98.41%; FP2005K: 98.28%; FP3005K: 98.43%; FP4010K: 98.45%; FP1955K: 98.20%; FP2935K: 98.35%; FP3915K: 98.37%; FP1910K: 98.18%; FP2865K: 98.33%; FP3820K: 98.35%; 530 V (all frames): 98.35% (preliminary); 500 V (all frames): 98.35% (preliminary); 480 V (all frames): 98.35% (preliminary)
Protection
- DC protection and disconnection
- High-speed fuses, Motorized DC disconnect switches
- AC protection and disconnection
- Circuit breaker
- Overvoltage protection
- Type II for AC and Type I+II for DC
- Ground fault / insulation monitoring
- Insulation monitoring device
- Humidity control
- Active heating
Environment
- Operating temperature
- From -40 °C to +60 °C, >40 °C power derating
- Storage temperature
- From -40 °C to +60 °C
- Relative humidity
- From 4% to 100%
- Max. altitude
- 2000 m / >2000 m power derating (Max. 4000 m)
- Ingress protection
- NEMA 3R / IP55
- Cooling
- Forced air cooling
Physical
- Dimensions W × D × H (m)
- 3.0 x 2.0 x 2.3
- Dimensions W × D × H (ft)
- 9.8 x 6.5 x 7.5
- Weight
- Frame 2: 8600; Frame 3: 9700; Frame 4: 10365Frame 2: 3900; Frame 3: 4400; Frame 4: 4700
Communication
- Communication
- Modbus TCP
- Display / user interface
- Standard
- Power plant controller
- Optional. Third party SCADA systems supported.
Certifications
- Safety standards
- UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2 / IEC 62477-1
- Grid codes
- IEEE 1547:2018 / UL 1741 SA & SB/ IEC 62116:2014
- Installation standard
- NEC 2023
Features
- Features
- This product provides advanced grid support capabilities, enabling up to 4* Battery Energy Storage Systems (BESS) to operate simultaneously. It also offers up to nine voltage levels to suit any battery technology. *Only available with Multi PCSK.(power-electronics.com)It offers the advantages of a central inverter with the modularity of string inverters.(power-electronics.com)Designed for easy field maintenance, with up to four FRUs (Field Replaceable Units).(power-electronics.com)Modularity. / Easy maintenance. / Advanced grid support. / Compatible with all battery technologies.Designed for easy on-site replacement, with a safe, reliable, and fast plug-and-play assembly system. Includes up to four FRUs (Field Replaceable Units).(bucket-software00.s3.eu-west-1.amazonaws.com)Enables DC power redistribution when one module fails. Lower energy losses = higher availability and efficiency.(bucket-software00.s3.eu-west-1.amazonaws.com)Capable of operating on any power system, with different modes depending on the application: grid-forming or grid-following.(bucket-software00.s3.eu-west-1.amazonaws.com)The three-level IGBT topology reduces power-stage losses, increases inverter efficiency, and minimizes total harmonic distortion—achieving high efficiency for the lowest levelized cost of energy (LCOE).(bucket-software00.s3.eu-west-1.amazonaws.com)Choose your model based on your specific requirements.(bucket-software00.s3.eu-west-1.amazonaws.com)Maximum power up to 1500 V / Up to 5360 kVA / Ten different voltage DC windows / Full grid support capability / Grid-forming capability / *Up to four independent BESS (*Only Multi PCSK)(bucket-software00.s3.eu-west-1.amazonaws.com)
Notes
- Notes
- Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2).Optional available for temperatures below -25 ºC.Battery short circuit disconnection has to be done on the battery side.Consult Power Electronics for other applicable standards/grid codes.Values at 1.00·Vac nom and CosPhi=1. The maximum AC output power must be limited to meet the P-Q capability requirement at the inverter level of some grid codes. Consult Power Electronics for derating curves.Consult Power Electronics for derating curves. In the event of overvoltage in the grid, the minimum DC voltage will vary proportionally with the AC voltage.Available from January 2027.
More PCS from Power Electronics
- Freemaq Multi PCSKBattery inverter with 2–4 separate DC inputs, 480–690 V AC (sheet V. 1.4.5)
- Freemaq Multi PCSKBattery inverter with 2 or 4 separate DC inputs, 690 V AC (Gen3 sheet V. 2.0.5)
- Freemaq Multi PCSKBattery inverter with 2 or 4 separate DC inputs, 720 V AC (Gen3 sheet V. 2.0.5)
- Freemaq Multi PCSM IECMV power station with 2 or 4 separate DC inputs, 33/34.5 kV, IEC (sheet V. 1.4.4)
- Freemaq Multi PCSM IECMV power station with 2 or 4 separate DC inputs, 20–34.5 kV, 690 V PCS, IEC (Gen3 sheet V. 2.0.5)
- Freemaq Multi PCSM IECMV power station with 2 or 4 separate DC inputs, 20–34.5 kV, 720 V PCS, IEC (Gen3 sheet V. 2.0.5)
- Freemaq Multi PCSM IECMV power station with 2 or 4 separate DC inputs, 33 kV, 690 V PCS, IEC (Gen3 sheet V. 3.0.0, preliminary)
- Freemaq Multi PCSM IECMV power station with 2 or 4 separate DC inputs, 33 kV, 720 V PCS, IEC (Gen3 sheet V. 3.0.0, preliminary)
- Freemaq Multi PCSM ULMV power station with 2 or 4 separate DC inputs, 12.47–34.5 kV, UL (sheet V. 1.4.4)
- Freemaq Multi PCSM ULMV power station with 2 or 4 separate DC inputs, 34.5 kV, 690 V PCS, UL (Gen3 sheet V. 2.0.4)
- Freemaq Multi PCSM ULMV power station with 2 or 4 separate DC inputs, 34.5 kV, 720 V PCS, UL (Gen3 sheet V. 2.0.4)
- Freemaq Multi PCSM ULMV power station with 2 or 4 separate DC inputs, 34.5 kV, 690 V PCS, UL (Gen3 sheet V. 3.0.0, preliminary)
Power Electronics Freemaq PCSK, in short
The Power Electronics Freemaq PCSK is a PCS rated 1500 kW, with max efficiency 98.95%, cooling Air and MV transformer built in: no. Its max efficiency (98.95%) is above the median of the 45 PCS listed (98.7%). Power Electronics has 25 other PCS on this site.
Questions about the Power Electronics Freemaq PCSK
- What are the main specifications of the Power Electronics Freemaq PCSK?
- Rated 1500 kW; Max efficiency 98.95%; Cooling Air; MV transformer built in: no. As printed on Power Electronics' datasheet (checked November 2026); the full list is on this page.
- Where can I find the Power Electronics Freemaq PCSK datasheet?
- Power Electronics publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
- Who makes the Power Electronics Freemaq PCSK?
- Power Electronics, with its head office in Valencia, Spain. It has 26 PCS on this site, including this one.
Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.
Values as Power Electronics prints them in the linked datasheet; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Power Electronics. Product and company names are trademarks of their owners, used only to identify the product.