APAR LV XLPE (120 C) insulated power cable
EB-XLPE insulated armoured aluminium power cable, 650/1100 V, as per IS 7098 Part 1
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 25–1000 mm²
- Voltage rating
- 650/1100 V
- Insulation
- EB-XLPE (120 C)
- Standards
- IS 7098 Part 1, IEC 60502-1
E-Beam irradiated ATC / XLPO solar cable
Solar DC cable, electron beam cross-linked, as per BS EN 50618/2014 and IEC 62930/2017
- Type
- Solar DC
- Conductor
- Tinned copper
- Cross-section
- 2.5–300 mm²
- Voltage rating
- 1.5 kV
- Insulation
- XLPO (electron beam cross-linked polyolefin co-polymer)
- Standards
- EN 50618, IEC 62930
LV control up to 61 cores, LV power up to 1000 sqmm, MV/HV power up to 66 kV
- Type
- NA
- Conductor
- NA
- Cross-section
- up to 1000 mm²
- Voltage rating
- 600/1000 V to 1100 V (LV); up to 66 kV (MV/HV)
- Insulation
- XLPE
- Standards
- IS 7098 Part 1, IEC 60502-1, BS 5467, IS 7098 Part 2, BS 6622, IEC 60502-2
- Type
- NA
- Conductor
- NA
- Cross-section
- 240–1000 mm²
- Voltage rating
- 38/66 kV
- Insulation
- XLPE, dry cured
- Standards
- IS 7098 Part 3, IEC 60840
MV Multicore Copper & Aluminium Armoured Power Cables
XLPE insulated, steel armoured, 6.6 to 33 kV
- Type
- MV power
- Conductor
- NA
- Cross-section
- 25–630 mm²
- Voltage rating
- 6.6 kV (E), 11 kV (E), 11 kV (UE), 22 kV (E), 33 kV (E)
- Insulation
- XLPE
- Standards
- IS 7098 Part 2, IEC 60502-2, BS 6622, AS 1429.1
MV Single Core Copper & Aluminium Armoured Power Cables
XLPE insulated, aluminium wire or strip armoured, 6.6 to 33 kV
- Type
- MV power
- Conductor
- NA
- Cross-section
- 25–1000 mm²
- Voltage rating
- 6.6 kV (E), 11 kV (E), 11 kV (UE), 22 kV (E), 33 kV (E)
- Insulation
- XLPE
- Standards
- IS 7098 Part 2, IEC 60502-2, BS 6622, AS 1429.1
- Type
- Solar DC
- Conductor
- NA
- Cross-section
- 1.5–400 mm²
- Voltage rating
- 1.0/1.0 kV AC; 1.5 kV DC
- Insulation
- Halogen-free cross-linked polyolefin (XLPO), electron beam cross-linked
- Standards
- EN 50618, IS 17293, IEC 62930
- Type
- Solar DC
- Conductor
- NA
- Cross-section
- NA
- Voltage rating
- 600 V / 1 kV / 2 kV (page); 1000 V / 2000 V (PDF)
- Insulation
- Thermoset cross-linked polyethylene (XLPE), Type RHW-2
- Standards
- UL 4703, UL 44
XLPE insulated, solid copper multicore control cable, unarmoured or armoured, PVC ST-2 jacket (Finvul-X)
- Type
- Control / instrumentation
- Conductor
- Copper
- Cross-section
- 1.5–2.5 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- IS 7098 (Part 1)
1100 V XLPE insulated, aluminium or copper conductor, unarmoured or armoured, PVC ST-2 jacket (Finvul-X)
- Type
- LV power
- Conductor
- NA
- Cross-section
- 4–1000 mm²
- Voltage rating
- 1100 V
- Insulation
- XLPE
- Standards
- IS 7098 (Part 1)
Finopower XLPE insulated, 1.9/3.3 kV to 19/33 kV, aluminium or copper conductor, unarmoured or armoured
- Type
- MV power
- Conductor
- NA
- Cross-section
- 25–1000 mm²
- Voltage rating
- 1.9/3.3 kV to 19/33 kV
- Insulation
- XLPE
- Standards
- IS 7098 (Part 2)
Single-conductor tinned copper PV string cable, electron-beam cross-linked
- Type
- Solar DC
- Conductor
- Tinned copper
- Cross-section
- 1.5–400 mm²
- Voltage rating
- 1.0/1.0 kV AC; 1.5 kV DC
- Insulation
- Electron Beam Cross-Linked Halogen-free & Flame Retardant Compound (XLPO)
- Standards
- EN 50618, IEC 62930, IS 17293
- Type
- MV power
- Conductor
- NA
- Cross-section
- up to 1000 mm²
- Voltage rating
- 3.3 KV to 33 KV
- Insulation
- XLPE
- Standards
- IS 7098 Part-2, IEC 60502 Part-2, BS 6622
Specs not published
- Type
- MV power
- Conductor
- NA
- Cross-section
- NA
- Voltage rating
- 3.6/6.0 (7.2) kV to 18/30 (36) kV
- Insulation
- XLPE
- Standards
- IEC 60502-2
Specs not published
- Type
- LV power
- Conductor
- NA
- Cross-section
- up to 1000 mm²
- Voltage rating
- 1.1 KV
- Insulation
- PVC
- Standards
- IS 1554 Part-I
- Type
- LV power
- Conductor
- NA
- Cross-section
- NA
- Voltage rating
- NA
- Insulation
- NA
- Standards
- NA
- Type
- Solar DC
- Conductor
- Tinned copper
- Cross-section
- 1.5–240 mm²
- Voltage rating
- 0.6/1.0 kV AC / 1500 Volt DC
- Insulation
- Extruded cross linked ZHFR thermosetting
- Standards
- BS EN 50618
- Type
- MV power
- Conductor
- Aluminium
- Cross-section
- 25–1000 mm²
- Voltage rating
- 1.9/3.3 kV to 33/33 kV (E)
- Insulation
- XLPE
- Standards
- IS 7098 Part 2, IEC 60502-2, AS/NZS 1429.1, SANS 1339, SANS 1507
- Type
- MV power
- Conductor
- Copper
- Cross-section
- 25–1000 mm²
- Voltage rating
- 1.9/3.3 kV to 33/33 kV (E)
- Insulation
- XLPE
- Standards
- IS 7098 Part 2, IS 8130, IS 3975, IS 10810, IEC 60502-2, AS/NZS 1429.1, BS 7835, BS 6622, SANS 1339, SANS 1507
- Type
- Control / instrumentation
- Conductor
- NA
- Cross-section
- 1.5–2.5 mm²
- Voltage rating
- 1.1 kV
- Insulation
- XLPE and PVC
- Standards
- IS 7098 Part 1, IS 1554 Part 1, IEC 60502-1, AS/NZS 5000.1, BS 5467, BS 6724
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 6–1000 mm²
- Voltage rating
- 1.1 kV
- Insulation
- XLPE; PVC
- Standards
- IS 7098 Part 1, IS 1554 Part 1, IEC 60502-1, AS/NZS 5000.1
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 6–1000 mm²
- Voltage rating
- 1.1 kV
- Insulation
- XLPE; PVC
- Standards
- IS 7098 Part 1, IS 1554 Part 1, IEC 60502-1, AS/NZS 5000.1, BS 6724, BS 5467
- Type
- Solar DC
- Conductor
- Tinned copper
- Cross-section
- NA
- Voltage rating
- 1100 Vac/1800 Vdc
- Insulation
- XLPO / cross linked polyolefin compound
- Standards
- 2PFG 1169/08-2007
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 4–1000 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 25–1000 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 4–1000 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 25–1000 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 1.5–400 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 25–400 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 1.5–400 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 25–400 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 1.5–400 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 25–400 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 1.5–400 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 25–400 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 25–400 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 25–400 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 25–400 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 25–400 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 1.5–400 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Aluminium
- Cross-section
- 16–400 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 1.5–400 mm²
- Voltage rating
- NA
- Insulation
- PVC
- Standards
- NA
- Type
- LV power
- Conductor
- Copper
- Cross-section
- 16–400 mm²
- Voltage rating
- NA
- Insulation
- XLPE
- Standards
- NA
- Type
- Control / instrumentation
- Conductor
- NA
- Cross-section
- 1.5–2.5 mm²
- Voltage rating
- NA
- Insulation
- General Purpose / HR PVC
- Standards
- IS 1554 (Pt - I) - 1988
- Type
- Solar DC
- Conductor
- Tinned copper
- Cross-section
- 1.5–240 mm²
- Voltage rating
- 0.6/1.0 kV
- Insulation
- Cross linked halogen-free polyolefin
- Standards
- 2Pfg 1169/08.2007, BSEN 50618
- Type
- Control / instrumentation
- Conductor
- NA
- Cross-section
- 1.5–2.5 mm²
- Voltage rating
- 1100 V
- Insulation
- PVC
- Standards
- IS 1554 (Pt - I) - 1988
- Type
- Solar DC
- Conductor
- Tinned copper
- Cross-section
- 1.5–240 mm²
- Voltage rating
- 1.5 kV DC
- Insulation
- Crosslinked halogen free & flame retardant
- Standards
- 2 Pfg 1169/08.2007, EN 50618
- Type
- NA
- Conductor
- NA
- Cross-section
- 25–1000 mm²
- Voltage rating
- 3.8/6.6 kV (E); 6.35/11 kV (E), 6.6/6.6 kV (UE); 11/11 kV (UE); 12.7/22 kV (E); 19/33 kV (E)
- Insulation
- XLPE
- Standards
- IS 7098 Part-2/1985
| Details | Add to plan, favourite | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| APAR Industries | APAR LV XLPE (120 C) insulated power cableEB-XLPE insulated armoured aluminium power cable, 650/1100 V, as per IS 7098 Part 1 | LV power | Aluminium | 25–1000 mm² | 650/1100 V | EB-XLPE (120 C) | IS 7098 Part 1, IEC 60502-1 | ||
| APAR Industries | E-Beam irradiated ATC / XLPO solar cableSolar DC cable, electron beam cross-linked, as per BS EN 50618/2014 and IEC 62930/2017 | Solar DC | Tinned copper | 2.5–300 mm² | 1.5 kV | XLPO (electron beam cross-linked polyolefin co-polymer) | EN 50618, IEC 62930 | ||
| APAR Industries | XLPE Cables (LT/MV/HV)LV control up to 61 cores, LV power up to 1000 sqmm, MV/HV power up to 66 kV | NA | NA | up to 1000 mm² | 600/1000 V to 1100 V (LV); up to 66 kV (MV/HV) | XLPE | IS 7098 Part 1, IEC 60502-1, BS 5467, IS 7098 Part 2, BS 6622, IEC 60502-2 | ||
| Dynamic Cables | 66 kV EHV Power Cable38/66 kV XLPE single and three core | NA | NA | 240–1000 mm² | 38/66 kV | XLPE, dry cured | IS 7098 Part 3, IEC 60840 | ||
| Dynamic Cables | MV Multicore Copper & Aluminium Armoured Power CablesXLPE insulated, steel armoured, 6.6 to 33 kV | MV power | NA | 25–630 mm² | 6.6 kV (E), 11 kV (E), 11 kV (UE), 22 kV (E), 33 kV (E) | XLPE | IS 7098 Part 2, IEC 60502-2, BS 6622, AS 1429.1 | ||
| Dynamic Cables | MV Single Core Copper & Aluminium Armoured Power CablesXLPE insulated, aluminium wire or strip armoured, 6.6 to 33 kV | MV power | NA | 25–1000 mm² | 6.6 kV (E), 11 kV (E), 11 kV (UE), 22 kV (E), 33 kV (E) | XLPE | IS 7098 Part 2, IEC 60502-2, BS 6622, AS 1429.1 | ||
| Dynamic Cables | Solar DC CableSingle core photovoltaic cable, EN 50618 / IS 17293:2020 / IEC 62930 | Solar DC | NA | 1.5–400 mm² | 1.0/1.0 kV AC; 1.5 kV DC | Halogen-free cross-linked polyolefin (XLPO), electron beam cross-linked | EN 50618, IS 17293, IEC 62930 | ||
| Dynamic Cables | UL 4703 PV WirePhotovoltaic wire to UL 4703 for the US market | Solar DC | NA | NA | 600 V / 1 kV / 2 kV (page); 1000 V / 2000 V (PDF) | Thermoset cross-linked polyethylene (XLPE), Type RHW-2 | UL 4703, UL 44 | ||
| Finolex Cables | Finolex LV Control CableXLPE insulated, solid copper multicore control cable, unarmoured or armoured, PVC ST-2 jacket (Finvul-X) | Control / instrumentation | Copper | 1.5–2.5 mm² | NA | XLPE | IS 7098 (Part 1) | ||
| Finolex Cables | Finolex LV Power Cable1100 V XLPE insulated, aluminium or copper conductor, unarmoured or armoured, PVC ST-2 jacket (Finvul-X) | LV power | NA | 4–1000 mm² | 1100 V | XLPE | IS 7098 (Part 1) | ||
| Finolex Cables | Finolex MV CableFinopower XLPE insulated, 1.9/3.3 kV to 19/33 kV, aluminium or copper conductor, unarmoured or armoured | MV power | NA | 25–1000 mm² | 1.9/3.3 kV to 19/33 kV | XLPE | IS 7098 (Part 2) | ||
| Finolex Cables | Solar Endura PV CablesSingle-conductor tinned copper PV string cable, electron-beam cross-linked | Solar DC | Tinned copper | 1.5–400 mm² | 1.0/1.0 kV AC; 1.5 kV DC | Electron Beam Cross-Linked Halogen-free & Flame Retardant Compound (XLPO) | EN 50618, IEC 62930, IS 17293 | ||
| Gem Cables | HT XLPE Cables | MV power | NA | up to 1000 mm² | 3.3 KV to 33 KV | XLPE | IS 7098 Part-2, IEC 60502 Part-2, BS 6622 | ||
| Gem Cables | IEC LV Power, Control, PVC Wire and Flexible Cables | Specs not published | |||||||
| Gem Cables | IEC Medium Voltage Cables | MV power | NA | NA | 3.6/6.0 (7.2) kV to 18/30 (36) kV | XLPE | IEC 60502-2 | ||
| Gem Cables | Instrumentation Cables | Specs not published | |||||||
| Gem Cables | LT PVC Cables | LV power | NA | up to 1000 mm² | 1.1 KV | PVC | IS 1554 Part-I | ||
| Gem Cables | LT XLPE Cables | LV power | NA | NA | NA | NA | NA | ||
| Gem Cables | Solar Cable | Solar DC | Tinned copper | 1.5–240 mm² | 0.6/1.0 kV AC / 1500 Volt DC | Extruded cross linked ZHFR thermosetting | BS EN 50618 | ||
| Havells India | HT Power Cable Aluminium Conductor | MV power | Aluminium | 25–1000 mm² | 1.9/3.3 kV to 33/33 kV (E) | XLPE | IS 7098 Part 2, IEC 60502-2, AS/NZS 1429.1, SANS 1339, SANS 1507 | ||
| Havells India | HT Power Cable Copper Conductor | MV power | Copper | 25–1000 mm² | 1.9/3.3 kV to 33/33 kV (E) | XLPE | IS 7098 Part 2, IS 8130, IS 3975, IS 10810, IEC 60502-2, AS/NZS 1429.1, BS 7835, BS 6622, SANS 1339, SANS 1507 | ||
| Havells India | LT Control Cables | Control / instrumentation | NA | 1.5–2.5 mm² | 1.1 kV | XLPE and PVC | IS 7098 Part 1, IS 1554 Part 1, IEC 60502-1, AS/NZS 5000.1, BS 5467, BS 6724 | ||
| Havells India | LT Power Cable Aluminium Conductor | LV power | Aluminium | 6–1000 mm² | 1.1 kV | XLPE; PVC | IS 7098 Part 1, IS 1554 Part 1, IEC 60502-1, AS/NZS 5000.1 | ||
| Havells India | LT Power Cable Copper Conductor | LV power | Copper | 6–1000 mm² | 1.1 kV | XLPE; PVC | IS 7098 Part 1, IS 1554 Part 1, IEC 60502-1, AS/NZS 5000.1, BS 6724, BS 5467 | ||
| Havells India | Solar cable for solar plant | Solar DC | Tinned copper | NA | 1100 Vac/1800 Vdc | XLPO / cross linked polyolefin compound | 2PFG 1169/08-2007 | ||
| KEI Industries | 1 Core Aluminium PVC Armoured & Unarmoured Power Cables | LV power | Aluminium | 4–1000 mm² | NA | PVC | NA | ||
| KEI Industries | 1 Core Aluminium XLPE Armoured & Unarmoured Power Cables | LV power | Aluminium | 25–1000 mm² | NA | XLPE | NA | ||
| KEI Industries | 1 Core Copper PVC Armoured & Unarmoured Power Cables | LV power | Copper | 4–1000 mm² | NA | PVC | NA | ||
| KEI Industries | 1 Core Copper XLPE Armoured & Unarmoured Power Cables | LV power | Copper | 25–1000 mm² | NA | XLPE | NA | ||
| KEI Industries | 2 Core Aluminium PVC Armoured & Unarmoured Power Cables | LV power | Aluminium | 1.5–400 mm² | NA | PVC | NA | ||
| KEI Industries | 2 Core Aluminium XLPE Armoured & Unarmoured Power Cables | LV power | Aluminium | 25–400 mm² | NA | XLPE | NA | ||
| KEI Industries | 2 Core Copper PVC Armoured & Unarmoured Power Cables | LV power | Copper | 1.5–400 mm² | NA | PVC | NA | ||
| KEI Industries | 2 Core Copper XLPE Armoured & Unarmoured Power Cables | LV power | Copper | 25–400 mm² | NA | XLPE | NA | ||
| KEI Industries | 3 Core Aluminium PVC Armoured & Unarmoured Power Cables | LV power | Aluminium | 1.5–400 mm² | NA | PVC | NA | ||
| KEI Industries | 3 Core Aluminium XLPE Armoured & Unarmoured Power Cables | LV power | Aluminium | 25–400 mm² | NA | XLPE | NA | ||
| KEI Industries | 3 Core Copper PVC Armoured & Unarmoured Power Cables | LV power | Copper | 1.5–400 mm² | NA | PVC | NA | ||
| KEI Industries | 3 Core Copper XLPE Armoured & Unarmoured Power Cables | LV power | Copper | 25–400 mm² | NA | XLPE | NA | ||
| KEI Industries | 3.5 Core Aluminium PVC Armoured & Unarmoured Power Cables | LV power | Aluminium | 25–400 mm² | NA | PVC | NA | ||
| KEI Industries | 3.5 Core Aluminium XLPE Armoured & Unarmoured Power Cables | LV power | Aluminium | 25–400 mm² | NA | XLPE | NA | ||
| KEI Industries | 3.5 Core Copper PVC Armoured & Unarmoured Power Cables | LV power | Copper | 25–400 mm² | NA | PVC | NA | ||
| KEI Industries | 3.5 Core Copper XLPE Armoured & Unarmoured Power Cables | LV power | Copper | 25–400 mm² | NA | XLPE | NA | ||
| KEI Industries | 4 Core Aluminium PVC Armoured & Unarmoured Power Cables | LV power | Aluminium | 1.5–400 mm² | NA | PVC | NA | ||
| KEI Industries | 4 Core Aluminium XLPE Armoured & Unarmoured Power Cables | LV power | Aluminium | 16–400 mm² | NA | XLPE | NA | ||
| KEI Industries | 4 Core Copper PVC Armoured & Unarmoured Power Cables | LV power | Copper | 1.5–400 mm² | NA | PVC | NA | ||
| KEI Industries | 4 Core Copper XLPE Armoured & Unarmoured Power Cables | LV power | Copper | 16–400 mm² | NA | XLPE | NA | ||
| KEI Industries | Armoured PVC Control Cable | Control / instrumentation | NA | 1.5–2.5 mm² | NA | General Purpose / HR PVC | IS 1554 (Pt - I) - 1988 | ||
| KEI Industries | Cables for Photovoltaics (Solar Cables) | Solar DC | Tinned copper | 1.5–240 mm² | 0.6/1.0 kV | Cross linked halogen-free polyolefin | 2Pfg 1169/08.2007, BSEN 50618 | ||
| KEI Industries | Control Cables | Control / instrumentation | NA | 1.5–2.5 mm² | 1100 V | PVC | IS 1554 (Pt - I) - 1988 | ||
| KEI Industries | PV Solar Cables | Solar DC | Tinned copper | 1.5–240 mm² | 1.5 kV DC | Crosslinked halogen free & flame retardant | 2 Pfg 1169/08.2007, EN 50618 | ||
| KEI Industries | Single Core Aluminium & Copper Conductor XLPE Insulated Unarmoured & Armoured Cable | NA | NA | 25–1000 mm² | 3.8/6.6 kV (E); 6.35/11 kV (E), 6.6/6.6 kV (UE); 11/11 kV (UE); 12.7/22 kV (E); 19/33 kV (E) | XLPE | IS 7098 Part-2/1985 | ||
129 products
Values as each maker prints them on its own datasheet or spec page (linked from each product's page), checked November 2026 or earlier (the date we compared these figures with the maker's sheet). NA means the source doesn't publish it. Power and energy are rated figures; a range covers the variants on one sheet. Nothing here is tested by Ingro Energy, and the order is alphabetical (current models first, then announced and legacy ones) unless you sort a column.
Browse Solar and power cables by size
Each size has its own page with the products side by side.
Is your company on this list? Add it, update your details or raise a concern →
New to solar and power cables? What they are, and what each spec means
Solar DC cables connect panels to inverters and must handle sunlight, heat and high DC voltage for 25 years; AC power cables carry energy from inverters and batteries to the grid. The companies below make cables used across Indian solar and storage projects.
What to compare before you choose
- Rated DC voltage (1,000 V or 1,500 V) and the standard the solar cable is tested to, such as EN 50618 or IEC 62930.
- UV, ozone and temperature resistance for outdoor runs.
- Conductor material and size for your current and voltage drop.
- BIS certification and test reports for each batch.
129 products from 15 companies. Figures are as each maker publishes them in its datasheet; NA means not published. Ingro Energy is not affiliated with the companies listed.