Kehua BCS12500K~13800K-C-HUD-EP/T4 Series

Listed A–Z, not ranked · Reviewed November 2026

As printed in the spec page, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.

AC side

Rated power
12500–13800 kW
Printed ratings
12500, 13800 kW
Nominal AC voltage
690 V
Grid frequency
50/60

DC side

DC voltage range
1000–1500 V
Max DC current
NA

Performance

Max efficiency
NA

Build

Type
NA
Cooling
Liquid
Ingress protection
IP65(PCS) IP54(skid)
Operating temperature
-35–60 °C
Weight
43000–44000 kg
MV transformer built in
Yes
Communication
RS485, CAN, Ethernet, Modbus RTU, Modbus TCP, IEC 61850

Grid functions

Off-grid / black start
Yes
Grid-forming
Yes

Certification

Certifications
NA
Size:
12500 kW
, 13800 kW
Model code:
BCS12500K-C-HUD-EP/T4, BCS13800K-C-HUD-EP/T4
Checked:
November 2026, against the spec page

Note

MV power station (PCS with MV transformer); figures are for the station.

Full datasheet

Every row the maker prints, copied as written, read 2026-11-15.

Overview

Product
Integrated MV Power Conversion System(digitalenergy.kehua.com)
Series
BCS12500K~13800K-C-HUD-EP/T4 Series(digitalenergy.kehua.com)
Models
BCS12500K-C-HUD-EP/T4, BCS13800K-C-HUD-EP/T4(digitalenergy.kehua.com)

DC side

DC voltage range
1000-1500Vdc(digitalenergy.kehua.com)
Max. DC voltage
1500Vdc(digitalenergy.kehua.com)
Max. DC current
BCS12500K-C-HUD-EP/T4: 3507A*4; BCS13800K-C-HUD-EP/T4: 3872A*4(digitalenergy.kehua.com)

AC side

Rated AC power
BCS12500K-C-HUD-EP/T4: 12500kW; BCS13800K-C-HUD-EP/T4: 13800kW(digitalenergy.kehua.com)
Max. AC power
BCS12500K-C-HUD-EP/T4: 13750kVA; BCS13800K-C-HUD-EP/T4: 15180kVA(digitalenergy.kehua.com)
Nominal AC voltage
690Vac 3P3W+PE(digitalenergy.kehua.com)
AC voltage range
-15%~10% (settable)(digitalenergy.kehua.com)
Grid frequency range
50/60Hz(digitalenergy.kehua.com)
Max. AC current
BCS12500K-C-HUD-EP/T4: 11505.5A; BCS13800K-C-HUD-EP/T4: 12702A(digitalenergy.kehua.com)
Power factor
>0.99 (at rated power)(digitalenergy.kehua.com)
Adjustable power factor
1 (leading)~1 (lagging)(digitalenergy.kehua.com)
Current harmonic distortion (THDi)
<3% (at rated power)(digitalenergy.kehua.com)

Off-grid operation

Off-grid output voltage
690Vac(digitalenergy.kehua.com)
Off-grid frequency
50/60Hz(digitalenergy.kehua.com)
Off-grid output current
BCS12500K-C-HUD-EP/T4: 11505.5A; BCS13800K-C-HUD-EP/T4: 12702A(digitalenergy.kehua.com)
Off-grid voltage distortion (THDu)
<3% (linear load)(digitalenergy.kehua.com)
Output voltage accuracy
1%(digitalenergy.kehua.com)
Off-grid overload capability
110% overload(digitalenergy.kehua.com)

Efficiency

Max. efficiency
99%*(digitalenergy.kehua.com)

MV transformer and switchgear

MV / LV voltage
20~33kV / 0.69kV (can be customized)(digitalenergy.kehua.com)
Transformer rated power
BCS12500K-C-HUD-EP/T4: 12500kVA; BCS13800K-C-HUD-EP/T4: 13800kVA(digitalenergy.kehua.com)
Transformer isolation
Oil-immersed transformer(digitalenergy.kehua.com)

Environment

Operating temperature
-35ºC~60ºC (>45ºC derating)(digitalenergy.kehua.com)
Relative humidity
0~100% (no-condensing)(digitalenergy.kehua.com)
Max. altitude
4000m (>2000m derating)(digitalenergy.kehua.com)
Ingress protection
IP65(PCS) IP54(skid)(digitalenergy.kehua.com)
Cooling
Liquid cooling (PCS) ONAF (skid)(digitalenergy.kehua.com)

Physical

Dimensions (W × H × D)
12192×2896×2438mm(digitalenergy.kehua.com)
Weight
BCS12500K-C-HUD-EP/T4: 43000kg; BCS13800K-C-HUD-EP/T4: 44000kg(digitalenergy.kehua.com)

Communication

Communication
Modbus-RTU, Modbus-TCP, IEC61850, IEC104(digitalenergy.kehua.com)RS485, CAN, Ethernet(digitalenergy.kehua.com)
Display / user interface
LED(digitalenergy.kehua.com)

Features

Features
24/7 On-line insulation detection, ensure personnel and equipment safety(digitalenergy.kehua.com)Real-time transformer condition monitoring, ensure operational safety(digitalenergy.kehua.com)Noise ≤ 75dBA, better protecting the hearing of personnel(digitalenergy.kehua.com)Designed for extreme environment, such as high temperature, salt spray, and extreme cold etc.(digitalenergy.kehua.com)Integrated converter and transformer design enables turnkey solution(digitalenergy.kehua.com)Innovative top air outlet design, avoid heat island effect(digitalenergy.kehua.com)H/LVRT function, high adaptability to the grid(digitalenergy.kehua.com)Full-station grid-forming technology, supports black start & VSG functions(digitalenergy.kehua.com)Support operation under extremely weak grid conditions, SCR>1.0(digitalenergy.kehua.com)Two-way air duct & Self-cleaning, reduce maintenance frequency by 60%(digitalenergy.kehua.com)Integrated data acquisition and fiber ring network, intelligent O&M(digitalenergy.kehua.com)Support user log querying and fault recording waveform exporting, enhance O&M efficiency(digitalenergy.kehua.com)Adapt to extreme environment, such as high temperature, salt, and extreme cold etc.Integrated design of converter and transformer system, enables turnkey solutionH/LVRT function, high adaptation ability to the grid

Notes

Notes
This efficiency value was measured in a laboratory environment.(digitalenergy.kehua.com)Specification indexes may be subject to changes without further notice.(digitalenergy.kehua.com)

Kehua BCS12500K~13800K-C-HUD-EP/T4 Series, in short

The Kehua BCS12500K~13800K-C-HUD-EP/T4 Series is a PCS rated 12500 kW, with cooling Liquid and MV transformer built in. Kehua has 15 other PCS on this site.

Questions about the Kehua BCS12500K~13800K-C-HUD-EP/T4 Series

What are the main specifications of the Kehua BCS12500K~13800K-C-HUD-EP/T4 Series?
Rated 12500 kW; Cooling Liquid; MV transformer built in. As printed on Kehua's spec page (checked November 2026); the full list is on this page.
Where can I find the Kehua BCS12500K~13800K-C-HUD-EP/T4 Series spec page?
Kehua publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
Who makes the Kehua BCS12500K~13800K-C-HUD-EP/T4 Series?
Kehua, with its head office in Xiamen, China. It has 16 PCS on this site, including this one.

Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.

Values as Kehua prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Kehua. Product and company names are trademarks of their owners, used only to identify the product.

Not sure what to buy? Ask us what's compatible and what size fits your site.