Kehua BCS5000K~6900K-B-HUD/T Series

Listed A–Z, not ranked · Reviewed November 2026

As printed in the spec page, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.

AC side

Rated power
5000–6900 kW
Printed ratings
5000, 6000, 6900 kW
Nominal AC voltage
690 V
Grid frequency
50/60

DC side

DC voltage range
1000–1500 V
Max DC current
NA

Performance

Max efficiency
NA

Build

Type
NA
Cooling
Air
Ingress protection
IP55(PCS) IP54(skid)
Operating temperature
-35–60 °C
Weight
28100–31500 kg
MV transformer built in
Yes
Communication
RS485, CAN, Ethernet, Modbus RTU, Modbus TCP, IEC 61850

Grid functions

Off-grid / black start
Yes
Grid-forming
Yes

Certification

Certifications
NA
Size:
5000 kW
, 6000 kW
, 6900 kW
Model code:
BCS5000K-B-HUD/T, BCS6000K-B-HUD/T, BCS6900K-B-HUD/T
Checked:
November 2026, against the spec page

Note

MV power station (PCS with MV transformer); figures are for the station.

Full datasheet

Every row the maker prints, copied as written, read 2026-11-15.

Overview

Product
Integrated MV Power Conversion System(digitalenergy.kehua.com)
Series
BCS5000K~6900K-B-HUD/T Series(digitalenergy.kehua.com)
Models
BCS5000K-B-HUD/T, BCS6000K-B-HUD/T, BCS6900K-B-HUD/T(digitalenergy.kehua.com)

DC side

DC voltage range
1000-1500Vdc(digitalenergy.kehua.com)
Max. DC voltage
1500Vdc(digitalenergy.kehua.com)
Max. DC current
BCS5000K-B-HUD/T: 1403*4A; BCS6000K-B-HUD/T: 1683*4A; BCS6900K-B-HUD/T: 1936*4A(digitalenergy.kehua.com)

AC side

Rated AC power
BCS5000K-B-HUD/T: 5000kW; BCS6000K-B-HUD/T: 6000kW; BCS6900K-B-HUD/T: 6900kW(digitalenergy.kehua.com)
Max. AC power
BCS5000K-B-HUD/T: 5500kVA; BCS6000K-B-HUD/T: 6600kVA; BCS6900K-B-HUD/T: 7590kVA(digitalenergy.kehua.com)
Nominal AC voltage
690Vac 3P3W+PE(digitalenergy.kehua.com)
AC voltage range
-15%~10% (settable)(digitalenergy.kehua.com)
Grid frequency range
50/60Hz(digitalenergy.kehua.com)
Max. AC current
BCS5000K-B-HUD/T: 4602A; BCS6000K-B-HUD/T: 5523A; BCS6900K-B-HUD/T: 6351A(digitalenergy.kehua.com)
Power factor
>0.99 (at rated power)(digitalenergy.kehua.com)
Adjustable power factor
1 (leading)~1 (lagging)(digitalenergy.kehua.com)
Current harmonic distortion (THDi)
<3% (at rated power)(digitalenergy.kehua.com)

Off-grid operation

Off-grid output voltage
690Vac(digitalenergy.kehua.com)
Off-grid frequency
50/60Hz(digitalenergy.kehua.com)
Off-grid output current
BCS5000K-B-HUD/T: 4602A; BCS6000K-B-HUD/T: 5523A; BCS6900K-B-HUD/T: 6351A(digitalenergy.kehua.com)
Off-grid voltage distortion (THDu)
<3% (linear load)(digitalenergy.kehua.com)
Output voltage accuracy
1%(digitalenergy.kehua.com)
Off-grid overload capability
110% overload(digitalenergy.kehua.com)

Efficiency

Max. efficiency
99%*(digitalenergy.kehua.com)

MV transformer and switchgear

MV / LV voltage
10~33kV / 0.69kV (can be customized)(digitalenergy.kehua.com)
Transformer rated power
BCS5000K-B-HUD/T: 5000kVA; BCS6000K-B-HUD/T: 6000kVA; BCS6900K-B-HUD/T: 6900kVA(digitalenergy.kehua.com)
Transformer isolation
Oil-immersed transformer(digitalenergy.kehua.com)

Environment

Operating temperature
-35ºC~60ºC (>45ºC derating)(digitalenergy.kehua.com)
Relative humidity
0~100% (no-condensing)(digitalenergy.kehua.com)
Max. altitude
4000m (>2000m derating)(digitalenergy.kehua.com)
Ingress protection
IP55(PCS) IP54(skid)(digitalenergy.kehua.com)
Cooling
Intelligent air cooling (PCS) ONAN (skid)(digitalenergy.kehua.com)

Physical

Dimensions (W × H × D)
12192×2896×2438mm(digitalenergy.kehua.com)
Weight
BCS5000K-B-HUD/T: 28100kg; BCS6000K-B-HUD/T: 30000kg; BCS6900K-B-HUD/T: 31500kg(digitalenergy.kehua.com)

Communication

Communication
Modbus-RTU, Modbus-TCP, IEC61850, IEC104(digitalenergy.kehua.com)RS485, CAN, Ethernet(digitalenergy.kehua.com)
Display / user interface
Touch screen(digitalenergy.kehua.com)

Features

Features
On-line insulation detection(digitalenergy.kehua.com)Designed for extreme environment,such as high temperature(45ºC without derating), salt spray, and extreme cold etc.(digitalenergy.kehua.com)Real-time transformer condition monitoring(digitalenergy.kehua.com)High protection rating (PCS IP55, skid IP54) ensures reliable operation in dusty, humid, and saline conditions(digitalenergy.kehua.com)Wide voltage range, supporting flexible battery bank configuration and high-power energy storage(digitalenergy.kehua.com)Support user log querying and fault recording waveform exporting, enhance O&M efficiency(digitalenergy.kehua.com)Support GFM function with millisecond response(digitalenergy.kehua.com)Various applications such as VSG, frequency regulation, black-start, etc.(digitalenergy.kehua.com)High adaptability to the grid with low SCR(digitalenergy.kehua.com)Integrated data acquisition and optical fiber network, simplifying system networking and reducing wiring complexity(digitalenergy.kehua.com)Skid-mounted integrated design of converter and transformer enables integrated delivery, minimizing on-site installation and commissioning time(digitalenergy.kehua.com)Adapt to extreme environment, such as high temperature, salt, and extreme cold etc.Integrated data acquisition and optical fiber network, intelligent operation managementEfficient layout to improve space utilizationIntegrated design of converter and transformer system to achieve the integrated deliverySupport multi-machine parallel connection & blackstartH/LVRT function, high adaptation ability to the gridVarious applications such as peak shaving, frequency modulation, auxiliary grid connection for new energy system, etc.

Notes

Notes
This efficiency value was measured in a laboratory environment.(digitalenergy.kehua.com)Specification indexes may be subject to changes without further notice.(digitalenergy.kehua.com)

Kehua BCS5000K~6900K-B-HUD/T Series, in short

The Kehua BCS5000K~6900K-B-HUD/T Series is a PCS rated 5000 kW, with cooling Air and MV transformer built in. 16 other PCS at 5000 kW are listed, from 4 makers. Kehua has 15 other PCS on this site.

Same size from other makers: FIMER PVS980-58BC-5000-L, Hitachi Energy India PCS WD4, Power Electronics Freemaq Multi PCSK, Kehua BCS4000K~5000K-C-HUD-NP/T4, Power Electronics Freemaq Multi PCSK, Kehua BCS4000K~5000K-C-HUD/T4 Series · All 5000 kW side by side

Questions about the Kehua BCS5000K~6900K-B-HUD/T Series

What are the main specifications of the Kehua BCS5000K~6900K-B-HUD/T Series?
Rated 5000 kW; Cooling Air; MV transformer built in. As printed on Kehua's spec page (checked November 2026); the full list is on this page.
Where can I find the Kehua BCS5000K~6900K-B-HUD/T Series spec page?
Kehua publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
What are the alternatives to the Kehua BCS5000K~6900K-B-HUD/T Series?
Other 5000 kW PCS sold in India include FIMER PVS980-58BC-5000-L, Hitachi Energy India PCS WD4, Power Electronics Freemaq Multi PCSK and Kehua BCS4000K~5000K-C-HUD-NP/T4. All of them are compared side by side on the 5000 kW page.
Who makes the Kehua BCS5000K~6900K-B-HUD/T Series?
Kehua, with its head office in Xiamen, China. It has 16 PCS on this site, including this one.

Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.

Values as Kehua prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Kehua. Product and company names are trademarks of their owners, used only to identify the product.