Listed A–Z, not ranked · Reviewed November 2026
Specifications
As printed in the spec page, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.
AC side
- Rated power
- 2500–3450 kW
- Printed ratings
- 2500, 3000, 3450 kW
- Nominal AC voltage
- 690 V
- Grid frequency
- 50/60
DC side
- DC voltage range
- 1000–1500 V
- Max DC current
- NA
Performance
- Max efficiency
- NA
Build
- Type
- NA
- Cooling
- Air
- Ingress protection
- IP55(PCS) IP54(skid)
- Operating temperature
- -35–60 °C
- Weight
- 15100–17200 kg
- MV transformer built in
- Yes
- Communication
- RS485, Ethernet, Modbus RTU, Modbus TCP, IEC 61850
Grid functions
- Off-grid / black start
- Yes
- Grid-forming
- Yes
Certification
- Certifications
- NA
- Model code:
- BCS2500K-B-HUD/T, BCS3000K-B-HUD/T, BCS3450K-B-HUD/T
- Checked:
- November 2026, against the spec page
Note
MV power station (PCS with MV transformer); figures are for the station.
Full datasheet
Every row the maker prints, copied as written, read 2026-11-15.
Overview
- Product
- Integrated MV Power Conversion System(digitalenergy.kehua.com)
- Series
- BCS2500K~3450K-B-HUD/T Series(digitalenergy.kehua.com)
- Models
- BCS2500K-B-HUD/T, BCS3000K-B-HUD/T, BCS3450K-B-HUD/T(digitalenergy.kehua.com)
DC side
- DC voltage range
- 1000-1500Vdc(digitalenergy.kehua.com)
- Max. DC voltage
- 1500Vdc(digitalenergy.kehua.com)
- Max. DC current
- BCS2500K-B-HUD/T: 1403*2A; BCS3000K-B-HUD/T: 1683*2A; BCS3450K-B-HUD/T: 1936*2A(digitalenergy.kehua.com)
- Soft start
- Yes(digitalenergy.kehua.com)
AC side
- Rated AC power
- BCS2500K-B-HUD/T: 2500kW; BCS3000K-B-HUD/T: 3000kW; BCS3450K-B-HUD/T: 3450kW(digitalenergy.kehua.com)
- Max. AC power
- BCS2500K-B-HUD/T: 2750kVA; BCS3000K-B-HUD/T: 3300kVA; BCS3450K-B-HUD/T: 3795kVA(digitalenergy.kehua.com)
- Nominal AC voltage
- 690Vac 3P3W+PE(digitalenergy.kehua.com)
- AC voltage range
- -15%~10% (settable)(digitalenergy.kehua.com)
- Grid frequency range
- 50/60Hz(digitalenergy.kehua.com)
- Max. AC current
- BCS2500K-B-HUD/T: 2302A; BCS3000K-B-HUD/T: 2762A; BCS3450K-B-HUD/T: 3176A(digitalenergy.kehua.com)
- Power factor
- >0.99 (at rated power)(digitalenergy.kehua.com)
- Adjustable power factor
- 1 (leading)~1 (lagging)(digitalenergy.kehua.com)
- Current harmonic distortion (THDi)
- <3% (at rated power)(digitalenergy.kehua.com)
Off-grid operation
- Off-grid output voltage
- 690Vac(digitalenergy.kehua.com)
- Off-grid frequency
- 50/60Hz(digitalenergy.kehua.com)
- Off-grid output current
- BCS2500K-B-HUD/T: 2302A; BCS3000K-B-HUD/T: 2762A; BCS3450K-B-HUD/T: 3176A(digitalenergy.kehua.com)
- Off-grid voltage distortion (THDu)
- <3% (linear load)(digitalenergy.kehua.com)
- Output voltage accuracy
- 1%(digitalenergy.kehua.com)
- Off-grid overload capability
- 110% overload(digitalenergy.kehua.com)
Efficiency
- Max. efficiency
- 99%*(digitalenergy.kehua.com)
MV transformer and switchgear
- MV / LV voltage
- 10~33kV / 0.69kV (can be customized)(digitalenergy.kehua.com)
- Transformer rated power
- BCS2500K-B-HUD/T: 2500kVA; BCS3000K-B-HUD/T: 3000kVA; BCS3450K-B-HUD/T: 3450kVA(digitalenergy.kehua.com)
- Transformer isolation
- Oil-immersed transformer(digitalenergy.kehua.com)
Environment
- Operating temperature
- -35ºC~60ºC (>45ºC derating)(digitalenergy.kehua.com)
- Relative humidity
- 0~100% (no-condensing)(digitalenergy.kehua.com)
- Max. altitude
- 4000m (>2000m derating)(digitalenergy.kehua.com)
- Ingress protection
- IP55(PCS) IP54(skid)(digitalenergy.kehua.com)
- Cooling
- Intelligent air cooling (PCS) ONAN (skid)(digitalenergy.kehua.com)
Physical
- Dimensions (W × H × D)
- 6058×2896×2438mm(digitalenergy.kehua.com)
- Weight
- BCS2500K-B-HUD/T: 15100kg; BCS3000K-B-HUD/T: 16000kg; BCS3450K-B-HUD/T: 17200kg(digitalenergy.kehua.com)
Communication
- Communication
- Modbus-RTU, Modbus-TCP, IEC61850, IEC104(digitalenergy.kehua.com)RS485, Ethernet(digitalenergy.kehua.com)
- Display / user interface
- Touch screen(digitalenergy.kehua.com)
Features
- Features
- On-line insulation detection(digitalenergy.kehua.com)Designed for extreme environment,such as high temperature(45ºC without derating), salt spray, and extreme cold etc.(digitalenergy.kehua.com)Real-time transformer condition monitoring(digitalenergy.kehua.com)High protection rating (PCS IP55, skid IP54) ensures reliable operation in dusty, humid, and saline conditions(digitalenergy.kehua.com)Wide voltage range, supporting flexible battery bank configuration and high-power energy storage(digitalenergy.kehua.com)Support user log querying and fault recording waveform exporting, enhance O&M efficiency(digitalenergy.kehua.com)Support GFM function with millisecond response(digitalenergy.kehua.com)Various applications such as VSG, frequency regulation, black-start, etc.(digitalenergy.kehua.com)High adaptability to the grid with low SCR(digitalenergy.kehua.com)Integrated data acquisition and optical fiber network, simplifying system networking and reducing wiring complexity(digitalenergy.kehua.com)Skid-mounted integrated design of converter and transformer enables integrated delivery, minimizing on-site installation and commissioning time(digitalenergy.kehua.com)Adapt to extreme environment,such as high temperature, salt, and extreme cold etcIntegrated data acquisition and optical fiber network, intelligent operation managementEfficient layout to improve space utilizationIntegrated design of converter and transformer system to achieve the integrated deliverySupport multi-machine parallel connection & black startH/LVRT function, high adaptation ability to the gridVarious applications such as peak shaving, frequency modulation, auxiliary grid connection for new energy system, etc
Notes
- Notes
- This efficiency value was measured in a laboratory environment.(digitalenergy.kehua.com)Specification indexes may be subject to changes without further notice.(digitalenergy.kehua.com)
More PCS from Kehua
- BCS1000K~1250K-C-HUD
- BCS1000K~1250K-C-HUD-NP
- BCS100K~200K-B-HM X2
- BCS12500K~13800K-C-HUD-EP/T4 Series
- BCS1250K~1725K-B-HUD
- BCS2000K~2500K-C-HUD-NP/T2 Series
- BCS2000K~2500K-C-HUD/T2 Series
- BCS3150K~3500K-C-HUD-EP
- BCS4000K~5000K-C-HUD-NP/T4
- BCS4000K~5000K-C-HUD/T4 Series
- BCS5000K~6900K-B-HUD/T Series
- BCS500K-S-HLC
Kehua BCS2500K~3450K-B-HUD/T Series, in short
The Kehua BCS2500K~3450K-B-HUD/T Series is a PCS rated 2500 kW, with cooling Air and MV transformer built in. 3 other PCS at 2500 kW are listed, from 2 makers. Kehua has 15 other PCS on this site.
Same size from other makers: FIMER PVS980-58BC-2500-L, Kehua BCS2000K~2500K-C-HUD-NP/T2 Series, Kehua BCS2000K~2500K-C-HUD/T2 Series
Questions about the Kehua BCS2500K~3450K-B-HUD/T Series
- What are the main specifications of the Kehua BCS2500K~3450K-B-HUD/T Series?
- Rated 2500 kW; Cooling Air; MV transformer built in. As printed on Kehua's spec page (checked November 2026); the full list is on this page.
- Where can I find the Kehua BCS2500K~3450K-B-HUD/T Series spec page?
- Kehua publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
- What are the alternatives to the Kehua BCS2500K~3450K-B-HUD/T Series?
- Other 2500 kW PCS sold in India include FIMER PVS980-58BC-2500-L, Kehua BCS2000K~2500K-C-HUD-NP/T2 Series and Kehua BCS2000K~2500K-C-HUD/T2 Series.
- Who makes the Kehua BCS2500K~3450K-B-HUD/T Series?
- Kehua, with its head office in Xiamen, China. It has 16 PCS on this site, including this one.
Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.
Values as Kehua prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Kehua. Product and company names are trademarks of their owners, used only to identify the product.