Kehua BCS75K~175K-B-HM-US X2

Listed A–Z, not ranked · Reviewed November 2026

As printed in the spec page, checked November 2026 (the date we compared these figures with the maker's sheet). NA means not published.

AC side

Rated power
75–175 kW
Printed ratings
75, 125, 175 kW
Nominal AC voltage
480–600 V
Grid frequency
60

DC side

DC voltage range
720–1450 V
Max DC current
NA

Performance

Max efficiency
NA

Build

Type
Modular
Cooling
Air
Ingress protection
NEMA type 4X
Operating temperature
-35–60 °C
Weight
NA
MV transformer built in
No
Communication
RS485, Ethernet, CAN, Modbus RTU, Modbus TCP

Grid functions

Off-grid / black start
Yes
Grid-forming
Not stated

Certification

Certifications
UL 1741, CSA C22.2#107.1, IEEE 1547, IEEE 1547.1, UL 1741 SB, CFR 47 Part 15, ANSI C63.4
Size:
75 kW
, 125 kW
, 175 kW
Model code:
BCS75K-B-HM-US X2, BCS125K-B-HM-US X2, BCS175K-B-HM-US X2
Checked:
November 2026, against the spec page

Full datasheet

Every row the maker prints, copied as written, read 2026-11-15.

Overview

Product
Modular Energy Storage Converter (DC-AC)(digitalenergy.kehua.com)
Series
BCS125K-B-HM-US X2 Series(digitalenergy.kehua.com)
Models
BCS75K-B-HM-US X2, BCS125K-B-HM-US X2, BCS175K-B-HM-US X2
Topology
BCS125K-B-HM-US X2: Non-isolated(digitalenergy.kehua.com)

DC side

Full-power DC voltage range
BCS125K-B-HM-US X2: 720~1300Vdc(digitalenergy.kehua.com)BCS75K-B-HM-US X2: 720~1450VdcBCS175K-B-HM-US X2: 920~1450Vdc
Max. DC voltage
BCS125K-B-HM-US X2: 1500Vdc(digitalenergy.kehua.com)
Max. DC current
BCS125K-B-HM-US X2: 195A(digitalenergy.kehua.com)
Soft start
BCS125K-B-HM-US X2: Yes(digitalenergy.kehua.com)

AC side

Rated AC power
BCS125K-B-HM-US X2: 125kW@45°C(digitalenergy.kehua.com)BCS75K-B-HM-US X2: 75kW@45°CBCS175K-B-HM-US X2: 175kW@40°C
Nominal AC voltage
BCS125K-B-HM-US X2: 480Vac 3P3W(digitalenergy.kehua.com)BCS75K-B-HM-US X2: 480Vac 3P3WBCS175K-B-HM-US X2: 600Vac3P3W
AC voltage range
BCS125K-B-HM-US X2: -15%~10% (settable)(digitalenergy.kehua.com)
Grid frequency range
BCS125K-B-HM-US X2: 60Hz(digitalenergy.kehua.com)60Hz
Max. AC current
BCS125K-B-HM-US X2: 165.4A(digitalenergy.kehua.com)
Power factor
BCS125K-B-HM-US X2: >0.99 (at rated power)(digitalenergy.kehua.com)
Adjustable power factor
BCS125K-B-HM-US X2: 1 (leading)~1 (lagging)(digitalenergy.kehua.com)
Current harmonic distortion (THDi)
BCS125K-B-HM-US X2: <3% (at rated power)(digitalenergy.kehua.com)

Off-grid operation

Off-grid voltage distortion (THDu)
BCS125K-B-HM-US X2: <3% (linear load)(digitalenergy.kehua.com)

Efficiency

Max. efficiency
BCS125K-B-HM-US X2: 98.8%(digitalenergy.kehua.com)

Environment

Operating temperature
BCS125K-B-HM-US X2: -35°C~60°C/-31°F~140°F(>50°C/122°F derating)(digitalenergy.kehua.com)
Relative humidity
BCS125K-B-HM-US X2: 0~100% (no-condensing)(digitalenergy.kehua.com)
Max. altitude
BCS125K-B-HM-US X2: 4000m/13123ft(>2000m/6562ft derating)(digitalenergy.kehua.com)
Ingress protection
BCS125K-B-HM-US X2: NEMA type 4X(digitalenergy.kehua.com)NEMA type 4X
Cooling
BCS125K-B-HM-US X2: Intelligent air cooling(digitalenergy.kehua.com)

Physical

Dimensions (W × H × D)
BCS125K-B-HM-US X2: 600x295x900mm/23.6x11.6x35.4in(digitalenergy.kehua.com)
Weight
BCS125K-B-HM-US X2: 95kg/209.4lb(digitalenergy.kehua.com)
Installation
BCS125K-B-HM-US X2: Rack-mounted(digitalenergy.kehua.com)

Communication

Communication
BCS125K-B-HM-US X2: Modbus-RTU, Modbus-TCP(digitalenergy.kehua.com)BCS125K-B-HM-US X2: RS485, Ethernet, CAN, Sunspec(digitalenergy.kehua.com)
Display / user interface
BCS125K-B-HM-US X2: LED(digitalenergy.kehua.com)

Certifications

Certifications and standards
BCS125K-B-HM-US X2: UL 1741, CSA C22.2#107.1, IEEE 1547, IEEE 1547.1, UL 1741 SB, CFR 47 Part 15, ANSI C63.4(digitalenergy.kehua.com)

Features

Features
NEMA type 4X + C5, designed for extreme environments to provide reliable component protection(digitalenergy.kehua.com)Built-in two fuses on DC side(digitalenergy.kehua.com)Fast power scheduling(digitalenergy.kehua.com)Independent operation, non master-slave logic(digitalenergy.kehua.com)Non-limited parallel connection in theory(digitalenergy.kehua.com)Up to five units parallel connection in off-grid mode(digitalenergy.kehua.com)Fast plug & play, easy installation(digitalenergy.kehua.com)Modular design, support rack-mounted(digitalenergy.kehua.com)Support multi-module AC side parallel

Notes

Notes
Specification indexes may be subject to changes without further notice.(digitalenergy.kehua.com)

Kehua BCS75K~175K-B-HM-US X2, in short

The Kehua BCS75K~175K-B-HM-US X2 is a PCS rated 75 kW, with cooling Air and MV transformer built in: no. Kehua has 15 other PCS on this site.

Questions about the Kehua BCS75K~175K-B-HM-US X2

What are the main specifications of the Kehua BCS75K~175K-B-HM-US X2?
Rated 75 kW; Cooling Air; MV transformer built in: no. As printed on Kehua's spec page (checked November 2026); the full list is on this page.
Where can I find the Kehua BCS75K~175K-B-HM-US X2 spec page?
Kehua publishes it on its own website, and this page links to it. The figures here were last checked against it in November 2026.
Who makes the Kehua BCS75K~175K-B-HM-US X2?
Kehua, with its head office in Xiamen, China. It has 16 PCS on this site, including this one.

Spot a wrong or outdated figure? Report a correction and we'll check it against the maker's current sheet.

Values as Kehua prints them in the linked spec page; NA means it doesn't publish that figure. Nothing here is tested by Ingro Energy, and Ingro Energy is not affiliated with Kehua. Product and company names are trademarks of their owners, used only to identify the product.

Not sure what to buy? Ask us what's compatible and what size fits your site.