For a 125 kW / 261 kWh battery cabinet, Ingro EMS is the energy management system that runs it against the site's demand limit, ToD tariff, solar and diesel generator. Pack makers and integrators building this cabinet can put Ingro EMS inside it; site owners use it to run one cabinet or several as one battery. It works with any BMS and PCS, and runs on site, in the cloud or both.
Ingro does not make the battery. The cabinet or container can be any maker's, with any BMS and PCS; Ingro EMS is the controller and software that decides when it charges, discharges or holds.
What a battery of this size usually looks like on an Indian site.
Choosing the battery? 125 kW / 261 kWh cabinet makers in the Ingro directory
The sites that most often install a 125 kW / 261 kWh battery.
Peak shaving against the contract demand, ToD shifting and solar storage.
Backup that forms the site's own supply in a grid outage, with the DG as the last resort.
Fast chargers on the grid connection you have, with the battery covering coincident peaks.
Leave your details. An Ingro engineer gets back to you within one business day, no obligation.
The battery stores energy and the PCS converts it. The EMS decides what it earns, every control cycle.
Put Ingro EMS in your cabinet as its site controller, so you sell a battery that already does peak shaving, backup and solar, with a console and reports.
At Invertis University, four cabinets (500 kW / 1.04 MWh) run as one source: one lead and three followers.
The EMS discharges to keep demand under the limit and shifts energy out of the peak window, keeping a backup reserve.
The battery takes the outage first; the DG starts only if the outage outlasts the reserve.
Ingro EMS connects to the cabinet's BMS and PCS (usually Modbus TCP or RS485), the main meter, solar inverters and DG controller. It speaks Modbus TCP, Modbus RTU over RS485, SunSpec, IEC 61850, DNP3 and OPC-UA, plus dry contacts, digital I/O and aggregator gateways. Ingro EMS is deployed on site (offline), in the cloud, or as a hybrid of the two. In on-site and hybrid deployments, site control continues with no internet connection.
Building batteries of this size? Ingro EMS for integrators, EPCs and pack makers · Every BMS, PCS and protocol
Four 261 kWh-class cabinets, 500 kW / 1.04 MWh, run by Ingro EMS as one source.
5 questions
An EMS that reads the cabinet's BMS and PCS and the site's main meter, and runs peak shaving, ToD, backup, solar and DG together — and that runs several cabinets as one. Ingro EMS does this with any maker's cabinet, and is made in India.
One cabinet or a row of them as a single battery. At Invertis University it runs four as one source; at Tata Power-DDL's Rohini plant it runs 124 PCS units.
Send the battery size and make, the PCS, a year of electricity bills or the load profile, and what the battery must do (peak shaving, backup, solar, DG, dispatch). An engineer replies within one business day with a scope of supply.
Yes. Pack makers and integrators can put Ingro EMS in the cabinets they sell, so each cabinet arrives with a site controller, console and reports. Talk to the EMS team about integrating your BMS and PCS.
Any that expose their data. Ingro EMS speaks Modbus TCP, Modbus RTU over RS485, SunSpec, IEC 61850, DNP3 and OPC-UA, plus dry contacts, digital I/O and aggregator gateways.
Still have a question?
Share details of your site, hardware and tariff or tender, and an engineer will answer it.
One controller and one console, from a home battery to a grid-scale plant.
Send the battery and what it must do. An engineer replies within one business day.
Tell us the battery, the PCS and what it must do. An engineer replies within one business day with the EMS scope and the package that fits.